The initiating radical yields and the efficiency of polymerization for various dental photoinitiators excited by different light curing units

被引:128
|
作者
Neumann, MG
Schmitt, CC
Ferreira, GC
Corrêa, IC
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Rio de Janeiro, Fac Odontol, BR-21949900 Rio De Janeiro, Brazil
基金
巴西圣保罗研究基金会;
关键词
dental photoinitiators; light emitting diode (LED); quartz-tungsten-halogen (QTH); photopolymerization efficiency;
D O I
10.1016/j.dental.2005.06.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the efficiency of the photopolymerization of dental resins it is necessary to know to what extent the light emitted by the light curing units is absorbed by the photoinitiators. On the other hand, the efficiency of the absorbed photons to produce species that launch the polymerization process is also of paramount importance. Therefore, the previously determined PAE (photon absorption efficiency) is used in conjunction with the polymerization quantum yields for the photoinitiators, in order to be able to compare the total process on an equivalent basis. This parameter can be used to identify the best performance for the photochemical process with specific photoinitiators. Methods: The efficiency of LED (Ultrablue IS) and QTH (Optilux 401) lamps were tested comparing their performances with the photoinitiators camphorquinone (CQ); pheny[propanedione (PPD); monoacylphosphine oxide (Lucirin TPO); and bisacylphosphine oxide (Irgacure 819). The extent of photopolymerization per absorbed photon was determined from the polymerization quantum yields obtained by using the photoinitiators to polymerize methyl methacrylate, and afterwards combined with the previously determined PAEs. Results: Although CQ presents a rather low polymerization quantum yield, its photopolymerization efficiency is practically the highest when irradiated with the Ultrablue LED. On the other hand, Lucirin is much more efficient than the other photoinitiators when irradiated with a QTH lamp, due to its high quantum yield and the overlap between its absorption spectrum and the output of the visible lamp light. Significance: Difference in photopolymerization efficiencies arise when combinations of photoinitiators are used, and when LED sources are used in preference to QTH. Mechanistic understanding is essential to optimal initiator formulation. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:576 / 584
页数:9
相关论文
共 25 条
  • [1] Molar extinction coefficients and the photon absorption efficiency of dental photoinitiators and light curing units
    Neumann, MG
    Miranda, WG
    Schmitt, CC
    Rueggeberg, FA
    Correa, IC
    JOURNAL OF DENTISTRY, 2005, 33 (06) : 525 - 532
  • [2] Influence of different light curing units on the cytotoxicity of various dental composites
    Sigusch, Bernd W.
    Volpel, Andrea
    Braun, Ingo
    Uhl, Alexander
    Jandt, Klaus D.
    DENTAL MATERIALS, 2007, 23 (11) : 1342 - 1348
  • [3] Curing efficiency of various types of light-curing units
    Rahiotis, C
    Kakaboura, A
    Loukidis, M
    Vougiouklakis, G
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2004, 112 (01) : 89 - 94
  • [4] Efficiency of light curing units in a government dental school
    Nassar, Hani M.
    Ajaj, Reem
    Hasanain, Fatin
    JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 142 - 146
  • [5] Curing efficiency of various types of light-curing units.
    Rahiotis, C
    Kakaboura, A
    Fragouli, M
    Vougiouklakis, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B253 - B253
  • [6] The influence of various light curing units on the cytotoxicity of dental adhesives
    Sigusch, Bernd W.
    Pflaum, Torsten
    Voelpel, Andrea
    Schinkel, Matthias
    Jandt, Klaus D.
    DENTAL MATERIALS, 2009, 25 (11) : 1446 - 1452
  • [7] A comparison of efficiency of two photoinitiators for polymerization of light-cure dental composite resins
    Lizymol, P. P.
    Krishnan, V. Kalliyana
    JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 107 (05) : 3337 - 3342
  • [8] Bonding to Different PEEK Compositions: The Impact of Dental Light Curing Units
    Luemkemann, Nina
    Eichberger, Marlis
    Stawarczyk, Bogna
    MATERIALS, 2017, 10 (01):
  • [9] The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials
    Al Nahedh, H. N. A.
    Al-Senan, D. F.
    Alayad, A. S.
    OPERATIVE DENTISTRY, 2022, 47 (04) : E197 - E210
  • [10] Influence of heat from light curing units and dental composite polymerization on cells in vitro
    Uhl, A
    Völpel, A
    Sigusch, BW
    JOURNAL OF DENTISTRY, 2006, 34 (04) : 298 - 306