摘要
In Fluorescence Lifetime Imaging (FLIM) the ns fluorescence decay is used for imaging. It yields information about the local environment of the fluorescent molecule and is very well suited for quantitative imaging. FLIM was introduced more than one decade ago now. Most of the implementations of FLIM require comparatively long acquisition times on the order of ten seconds or more. This hampers the use of FLIM for the study of dynamic processes. In FLIM at least one order of magnitude more signal is required than in conventional intensity imaging. Therefore, fast FLIM acquisition rates require efficient detection schemes and detectors. We evaluated the count rate limitation in time gated and TCSPC FLIM of a number of single photon counting detectors. In particular we looked at the performance of a conventional fast head-on PMT (RI 894), a GaAs photocathode PMT (H7422P-40) and a single photon counting avalanche photo diode (SPCM-AQR14). The high quantum efficiency GaAs photocathode PMT and avalanche photo diode detectors show lifetime shifts in both time gated detection and in TCSPC starting at a detection count rate of 1 - 2 MHz. The conventional PMT shows lifetime shifts starting at a detection count rate of about 2.5 MHz in TCSPC and at about 6 MHz for the time gated detection system. The detection efficiency of the TCSPC based system goes down rapidly above about I MHz due to the dead time of the detection electronics. The time gated detection system shows little or no reduction of the detection efficiency up to detection count rates of 10 MHz with the conventional fast PMT. The time gated-detection system was coupled to a multi-photon excitation microscope. Calcium transients were recorded in cardiac rat myocytes at a I Hz frame rate. The system operated at the full repetition rate of the Ti:Sa laser. Here, the frame rate was limited by the maximum count rate of the PMT.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 50 条
  • [1] Multiphoton Multifoci Modulation Microscopy for High-Speed Fluorescence Lifetime Imaging
    Straub, Adam A.
    Howard, Scott S.
    Xu, Chris
    [J]. 2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [2] High-speed multispectral fluorescence lifetime imaging implementation for in vivo applications
    Shrestha, Sebina
    Applegate, Brian E.
    Park, Jesung
    Xiao, Xudong
    Pande, Paritosh
    Jo, Javier A.
    [J]. OPTICS LETTERS, 2010, 35 (15) : 2558 - 2560
  • [3] High speed multispectral fluorescence lifetime imaging
    Fereidouni, Farzad
    Reitsma, Keimpe
    Gerritsen, Hans C.
    [J]. OPTICS EXPRESS, 2013, 21 (10): : 11769 - 11782
  • [4] Development of a high-speed line-scanning fluorescence lifetime imaging microscope for biological imaging
    Mai, Hanning
    Jarman, Anneliese
    Erdogan, Ahmet T.
    Treacy, Conor
    Finlayson, Neil
    Henderson, Robert K.
    Poland, Simon P.
    [J]. OPTICS LETTERS, 2023, 48 (08) : 2042 - 2045
  • [5] Fluorescence lifetime imaging of high-speed particles with single-photon image sensors
    Gyongy, Istvan
    Green, Andrew
    Hutchings, Sam W.
    Davies, Amy
    Dutton, Neale A. W.
    Duncan, Rory R.
    Rickman, Colin
    Henderson, Robert K.
    Dalgarno, Paul A.
    [J]. HIGH-SPEED BIOMEDICAL IMAGING AND SPECTROSCOPY IV, 2019, 10889
  • [6] High-speed compressed-sensing fluorescence lifetime imaging microscopy of live cells
    Ma, Yayao
    Lee, Youngjae
    Best-Popescu, Catherine
    Gao, Liang
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (03)
  • [7] Frequency Doubled High Speed Fluorescence Lifetime Imaging
    Karpf, Sebastian
    Jalali, Bahram
    [J]. 2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [8] FLUORESCENCE LIFETIME IMAGING MICROSCOPY - HOMODYNE TECHNIQUE USING HIGH-SPEED GATED IMAGE INTENSIFIER
    SZMACINSKI, H
    LAKOWICZ, JR
    JOHNSON, ML
    [J]. NUMERICAL COMPUTER METHODS, PT B, 1994, 240 : 723 - 748
  • [9] High-speed confocal fluorescence lifetime imaging microscopy by analog mean-delay method
    Won, Youngjae
    Kim, Donguk
    Yang, Wenzhong
    Kim, Dug Y.
    [J]. IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VIII, 2010, 7568
  • [10] High-speed fluorescence lifetime measurement for investigation of dynamic phenomena
    Won, Youngjae
    Moon, Sucbei
    Lee, Dongsoo
    Kim, Dug Y.
    [J]. IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VII, 2009, 7182