Dynamic, six-axis stiffness matrix characteristics of the intact intervertebral disc and a disc replacement

被引:2
|
作者
Holsgrove, Timothy P. [1 ]
Gill, Harinderjit S. [1 ]
Miles, Anthony W. [1 ]
Gheduzzi, Sabina [1 ]
机构
[1] Univ Bath, Ctr Orthopaed Biomech, Bath BA2 7AY, Avon, England
关键词
Spine biomechanics; dynamic; stiffness; matrix; in vitro; total disc replacement; MOTION SEGMENT STIFFNESS; BIOMECHANICAL EVALUATION; AXIAL LOAD; LUMBAR; PORCINE; ARTHROPLASTY; KINEMATICS; BEHAVIOR; FUSION;
D O I
10.1177/0954411915610601
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thorough pre-testing is critical in assessing the likely in vivo performance of spinal devices prior to clinical use. However, there is a lack of data available concerning the dynamic testing of lumbar (porcine model) total disc replacements in all six axes under preload conditions. The aim of this study was to provide new data comparing porcine lumbar spinal specimen stiffness between the intact state and after the implantation of an unconstrained total disc replacement, in 6 degrees of freedom. The dynamic, stiffness matrix testing of six porcine lumbar isolated disc specimens was completed using triangle waves at a test frequency of 0.1Hz. An axial preload of 500N was applied during all testing. Specimens were tested both in the intact condition and after the implantation of the total disc replacement. Sixteen key stiffness terms were identified for the comparison of the intact and total disc replacement specimens, comprising the 6 principal stiffness terms and 10 key off-axis stiffness terms. The total disc replacement specimens were significantly different to the intact specimens in 12 of these key terms including all six principal stiffness terms. The implantation of the total disc replacement resulted in a mean reduction in the principal stiffness terms of 100%, 91%, and 98% in lateral bending, flexion-extension, and axial rotation, respectively. The novel findings of this study have demonstrated that the unconstrained, low-friction total disc replacement does not replicate the stiffness of the intact specimens. It is likely that other low-friction total disc replacements would produce similar results due to stiffness being actively minimised as part of the design of low-friction devices, without the introduction of stiffening elements or mechanisms to more accurately replicate the mechanical properties of the natural intervertebral disc. This study has demonstrated, for the first time, a method for the quantitative comparative mechanical function testing of total disc replacements and provides baseline data for the development of future devices.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [1] The dynamic, six-axis stiffness matrix testing of porcine spinal specimens
    Holsgrove, Timothy Patrick
    Gill, Harinderjit Singh
    Miles, Anthony W.
    Gheduzzi, Sabina
    SPINE JOURNAL, 2015, 15 (01): : 176 - 184
  • [2] Cervical Intervertebral Disc Replacement
    Cason, Garrick W.
    Herkowitz, Harry N.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (03): : 279 - 285
  • [3] The influence of geometry on intervertebral disc stiffness
    Tavana, S.
    Shek, C.
    Rahman, T.
    Baxan, N.
    Newell, N.
    JOURNAL OF BIOMECHANICS, 2024, 163
  • [4] Duration-dependent influence of dynamic torsion on the intervertebral disc: an intact disc organ culture study
    Samantha C. W. Chan
    Jochen Walser
    Stephen J. Ferguson
    Benjamin Gantenbein
    European Spine Journal, 2015, 24 : 2402 - 2410
  • [5] Duration-dependent influence of dynamic torsion on the intervertebral disc: an intact disc organ culture study
    Chan, Samantha C. W.
    Walser, Jochen
    Ferguson, Stephen J.
    Gantenbein, Benjamin
    EUROPEAN SPINE JOURNAL, 2015, 24 (11) : 2402 - 2410
  • [6] Intervertebral disc extrusion in six cats
    Knipe, M. F.
    Vernau, K. M.
    Hornof, W. J.
    LeCouteur, R. A.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2001, 3 (03) : 161 - 168
  • [7] A pilot study of intervertebral disc replacement
    Ross, ERS
    Tandon, V
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 1997, 9 (01) : 69 - 69
  • [8] Intervertebral disc replacement - Experimental study
    Kostuik, JP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (337) : 27 - 41
  • [9] Intervertebral disc degeneration in the dog. Part 1: Anatomy and physiology of the intervertebral disc and characteristics of intervertebral disc degeneration
    Bergknut, Niklas
    Smolders, Lucas A.
    Grinwis, Guy C. M.
    Hagman, Ragnvi
    Lagerstedt, Anne-Sofie
    Hazewinkel, Herman A. W.
    Tryfonidou, Marianna A.
    Meij, Bjorn P.
    VETERINARY JOURNAL, 2013, 195 (03): : 282 - 291
  • [10] Dynamic Characteristics Analysis of the Six-Axis Force/Torque Sensor
    Fu, Liyue
    Song, Aiguo
    JOURNAL OF SENSORS, 2018, 2018