Comparison of GMT presto assay and Roche cobase® 4800 CT/NG assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in dry swabs

被引:13
|
作者
de Waaij, Dewi J. [1 ,2 ]
Dubbink, Jan Henk [1 ,2 ]
Peters, Remco P. H. [3 ,4 ,5 ]
Ouburg, Sander [1 ]
Morre, Servaas A. [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Med Microbiol & Infect Control, Immunogenet Lab, Amsterdam, Netherlands
[2] Maastricht Univ, Res Sch GROW, Sch Oncol & Dev Biol, Fac Hlth Med & Life Sci,IPHG,Dept Genet & Cell Bi, NL-6200 MD Maastricht, Netherlands
[3] Anova Hlth Inst, Johannesburg, South Africa
[4] Anova Hlth Inst, Tzaneen, South Africa
[5] Maastricht Univ, Dept Med Microbiol, NL-6200 MD Maastricht, Netherlands
关键词
Chlamydia trachomatis; Neisseria gonorrhoeae; Real-time PCR; GMT presto assay; Roche cobas 4800 CT/NG test; URINE SPECIMENS; PCR; PERFORMANCE; INFECTIONS; AMPLICOR; STANDARD; CT;
D O I
10.1016/j.mimet.2015.08.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Urogenital Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are the most prevalent bacterial STIs worldwide. Molecular tests are the standard for the detection of CT and NG, as these are difficult to culture. The recently introduced CE-IVD marked GMT Presto assay promises to be a valuable addition in CT and NC diagnostics. The advantage of the Presto assay is that it works on many PCR systems and the DNA can be isolated by any system. We compared the Presto assay to the widely used Roche cobas (R) 4800 CT/NC test for the detection of CT and NC in 612 vaginal and rectal dry collected swabs. Discrepant samples were tested by the TIB MOLBIOL Lightmix Kit 480 HT CT/NC assay. The alloyed gold standard was defined as two concurring Presto and cobas (R) 4800 results, or, with discrepant Presto and cobas (R) results, two concurring results of either test together with the Lightmix Kit 480 HT CT/NC assay. For the Presto assay, we observed 77 CT positive (13%) and 22 NC positive (3,6%) vaginal samples, and 41 CT positive (6,7%) and 11 NC positive (1,8%) rectal samples. For the cobas (R) 4800 assay, we observed 77 CT positive (13%) and 21 NC positive (3,4%) vaginal samples, and 39 CT positive (6,4%) and 11 NC positive (1,8%) rectal samples. Ten CT samples were discrepant between Presto and cobas (R) 4800 CT/NC assays, while two NC samples were discrepant. CT sensitivity in both assays was 100% compared to the alloyed gold standard. The sensitivity was 100% for both vaginal and rectal dry swabs, underlining the suitability of these sample types for detection of CT and NC. The Presto assay is therefore valuable for molecular detection of CT and NC in dry vaginal and rectal swabs. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [1] Analytical Evaluation of the Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Rectal and Pharyngeal Swabs
    Adamson, Paul C.
    Pandori, Mark W.
    Doernberg, Sarah B.
    Komarow, Lauren
    Sund, Zoe
    Tran, Thuy Tien T.
    Jensen, David
    Tsalik, Ephraim L.
    Deal, Carolyn D.
    Chambers, Henry F.
    Fowler, Vance G., Jr.
    Evans, Scott R.
    Patel, Robin
    Klausner, Jeffrey D.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (06): : 811 - 816
  • [2] Detection of Neisseria gonorrhoeae or Chlamydia trachomatis from oral wash specimens using the Abbott RealTime CT/NG assay and the Cobas 4800 CT/NG assay: A prospective study
    Matsumoto, Masahiro
    Hamasuna, Ryoichi
    Le, Phuong Thi
    Fujimoto, Naohiro
    Matsumoto, Tetsuro
    [J]. JOURNAL OF INFECTION AND CHEMOTHERAPY, 2022, 28 (04) : 480 - 485
  • [3] Despite Excellent Test Characteristics of the cobas 4800 CT/NG Assay, Detection of Oropharyngeal Chlamydia trachomatis and Neisseria gonorrhoeae Remains Challenging
    van Niekerk, J. M.
    van der Veer, B. M. J. W.
    Hoebe, C. J. P. A.
    van de Bovenkamp, J.
    van Herk, C.
    van Loo, I. H. M.
    van Alphen, L. B.
    Wolffs, P. F. G.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (02)
  • [4] Vaginal Swabs Are the Optimal Specimen for Detection of Genital Chlamydia trachomatis or Neisseria gonorrhoeae Using the Cobas 4800 CT/NG Test
    Van Der Pol, Barbara
    Taylor, Stephanie N.
    Liesenfeld, Oliver
    Williams, James A.
    Hook, Edward W., III
    [J]. SEXUALLY TRANSMITTED DISEASES, 2013, 40 (03) : 247 - 250
  • [5] Comparison of analytical performances of the Roche Cobas 6800 CT/NG assay with the Abbott m2000 Real Time CT/NG assay for detecting Chlamydia trachomatis and Neisseria gonorrhoeae
    Cherkaoui, Abdessalam
    Renzi, Gesuele
    Mombelli, Michele
    Jaton, Katia
    Yerly, Sabine
    Vuilleumier, Nicolas
    Schrenzel, Jacques
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2019, 68 (02) : 197 - 200
  • [6] Is confirmatory testing of Roche cobas 4800 CT/NG test Neisseria gonorrhoeae positive samples required? Comparison of the Roche cobas 4800 CT/NG test with an opa/pap duplex assay for the detection of N gonorrhoeae
    Perry, Michael D.
    Jones, Rachel N.
    Corden, Sally A.
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2014, 90 (04) : 303 - 308
  • [7] Comparison of the Cepheid GeneXpert CT/NG assay to the Hologic Aptima Combo2 assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in self-collected rectal swabs
    Dize, Laura
    Silver, Barbara
    Gaydos, Charlotte
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2018, 90 (02) : 83 - 84
  • [8] Chlamydia trachomatis and Neisseria gonorrhoeae (CT/NG) Detection in SurePath and ThinPrep Specimens Using Abbot RealTime CT/NG Assay
    Lucic, D.
    Eisenhut, C.
    Cloherty, G.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 896 - 896
  • [9] Evaluation of Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Cervical Swabs from Female Sex Workers in China
    Han, Yan
    Yin, Yue-ping
    Shi, Mei-qin
    Zheng, Bing-jie
    Zhong, Ming-ying
    Jiang, Ning
    Chen, Shao-chun
    Chen, Xiang-sheng
    [J]. PLOS ONE, 2014, 9 (03):
  • [10] Evaluation of the cobas 4800 CT/NG test for detecting Chlamydia trachomatis and Neisseria gonorrhoeae
    Rockett, Rebecca
    Goire, Namraj
    Limnios, Athena
    Turra, Mark
    Higgens, Geoffrey
    Lambert, Stephen B.
    Bletchly, Cheryl
    Nissen, Michael D.
    Sloots, Theo P.
    Whiley, David M.
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2010, 86 (06) : 470 - 473