Carbon nanotube based microfocus field emission x-ray source for microcomputed tomography

被引:139
|
作者
Liu, Zejian [1 ]
Yang, Guang
Lee, Yueh Z.
Bordelon, David
Lu, Jianping
Zhou, Otto
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Sch Med, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Curriculum Appl & Mat Sci, Chapel Hill, NC 27599 USA
关键词
D O I
10.1063/1.2345829
中图分类号
O59 [应用物理学];
学科分类号
摘要
Microcomputed tomography is now widely used for in vivo small animal imaging for cancer studies. Achieving high imaging quality of live objects requires the x-ray source to have both high spatial and temporal resolutions. Preliminary studies have shown that carbon nanotube (CNT) based field emission x-ray source has significant intrinsic advantages over the conventional thermionic x-ray tube including better temporal resolution and programmability. Here we report the design and characterization of a CNT based field emission x-ray source that also affords a high spatial resolution. The device uses modified asymmetric Einzel lenses for electron focusing and an elliptical shaped CNT cathode patterned by photolithography. Stable and small isotropic x-ray focal spot sizes were obtained. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] A nanotube-based field emission x-ray source for microcomputed tomography
    Zhang, J
    Cheng, Y
    Lee, YZ
    Gao, B
    Qiu, Q
    Lin, WL
    Lalush, D
    Lu, JP
    Zhou, O
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09):
  • [2] Micro Computed Tomography System Based on Field Emission X-Ray Source with Carbon Nanotube Emitter
    Kim, Wooseob
    Gupta, Amar Prasad
    Jang, Jaekyu
    Jung, Jaeik
    Ryu, Jehwang
    [J]. MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [3] Multibeam X-Ray Source Array Based on Carbon Nanotube Field Emission
    Zhou, O.
    Lu, J.
    Calderon-Colon, X.
    Qian, X.
    Yang, G.
    Cao, G.
    Gidcumb, E.
    Tucker, A.
    Shan, J.
    Spronk, D.
    Sprenger, F.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Carbon Nanotube Field Emission X-ray System for Computed Tomography
    Ryu, Je Hwang
    Kim, Wan Sun
    Lee, Seung Ho
    Kang, Jung Su
    Kim, Jae Gon
    Lee, Soo Yeol
    Park, Kyu Chang
    Park, Hun Kuk
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [5] Fast microfocus x-ray tube based on carbon nanotube array
    Li, Xiaobing
    Zhou, Juntao
    Wu, Qingyang
    Liu, Menglong
    Zhou, Rifeng
    Chen, Zexiang
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2019, 37 (05):
  • [6] Effect of a concave grid mesh in a carbon nanotube-based field emission X-ray source
    Kim, Hyun Suk
    Castro, Edward Joseph D.
    Lee, Choong Hun
    [J]. MATERIALS RESEARCH BULLETIN, 2014, 58 : 107 - 111
  • [7] A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source
    Cao, G.
    Lee, Y. Z.
    Peng, R.
    Liu, Z.
    Rajaram, R.
    Calderon-Colon, X.
    An, L.
    Wang, P.
    Phan, T.
    Sultana, S.
    Lalush, D. S.
    Lu, J. P.
    Zhou, O.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : 2323 - 2340
  • [8] Dynamic radiography using a carbon-nanotube-based field-emission x-ray source
    Cheng, Y
    Zhang, J
    Lee, YZ
    Gao, B
    Dike, S
    Lin, W
    Lu, JP
    Zhou, O
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3264 - 3267
  • [9] A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application
    Wang, Sigen
    Calderon, Xiomara
    Peng, Rui
    Schreiber, Eric C.
    Zhou, Otto
    Chang, Sha
    [J]. APPLIED PHYSICS LETTERS, 2011, 98 (21)
  • [10] Stationary scanning x-ray source based on carbon nanotube field emitters
    Zhang, J
    Yang, G
    Cheng, Y
    Gao, B
    Qiu, Q
    Lee, YZ
    Lu, JP
    Zhou, O
    [J]. APPLIED PHYSICS LETTERS, 2005, 86 (18) : 1 - 3