Gamma-ray imaging with position-sensitive HPGe detectors

被引:43
|
作者
Vetter, K [1 ]
Burks, M [1 ]
Mihailescu, L [1 ]
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
关键词
Compton camera; HPGe detectors; gamma-ray tracking; gamma-ray imaging;
D O I
10.1016/j.nima.2004.03.087
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Due to advances in manufacturing large and highly segmented HPGe detectors along with the availability of fast and high-precision digital electronics, it is now possible to build efficient and high-resolution Compton cameras. Two-dimensionally segmented semi-conductor detectors along with pulse-shape analysis allow to obtain three-dimensional positions and energies of individual gamma-ray interactions. By employing gamma-ray tracking procedures it is possible to determine the scattering sequence in the detector and ultimately to deduce the incident direction of gamma rays without the use of a attenuating collimator. These advanced gamma-ray tracking-based Compton cameras are able not only to image gamma-ray sources with higher sensitivity than collimator-based systems but can increase the sensitivity in finding gamma-ray sources over non-imaging detectors, particularly in complex radiation fields. We have implemented a Compton camera built of a single double-sided strip HPGe detector with a strip pitch size of 2 mm. A three-dimensional position resolution of 0.5 mm at 122 keV by using simple pulse-shape analysis is achieved. We have implemented image reconstruction procedures for search scenarios, which are of interest for national security applications. In addition, we have developed reconstruction procedures to optimize image quality which potentially finds applications in other areas as well. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 50 条
  • [1] Gamma-ray imaging with thick position-sensitive silicon detectors
    Rowland-Fitzgerald, C.
    Kurfess, J. D.
    Phlips, B. F.
    Wulf, E. A.
    Novikova, E. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 323 - 326
  • [2] Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy
    Amman, M
    Luke, PN
    [J]. HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 144 - 156
  • [3] A POSITION-SENSITIVE DETECTOR FOR A GAMMA-RAY IMAGING TELESCOPE
    CARTER, JN
    CHARALAMBOUS, P
    DEAN, AJ
    STEPHEN, JB
    BUTLER, RC
    DICOCCO, G
    MORELLI, E
    SPADA, G
    SPIZZICHINO, A
    BARBARESCHI, L
    BOELLA, G
    PEROTTI, F
    VILLA, G
    BADIALI, M
    LAPADULA, C
    POLCARO, F
    UBERTINI, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (2-3): : 477 - 482
  • [4] Position-sensitive avalanche photodiodes for gamma-ray imaging
    Shah, KS
    Farrell, R
    Grazioso, R
    Harmon, ES
    Karplus, E
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1687 - 1692
  • [5] COMPTON SCATTER IN GERMANIUM AND ITS EFFECT ON IMAGING WITH GAMMA-RAY POSITION-SENSITIVE DETECTORS
    SHERMAN, IS
    STRAUSS, MG
    BRENNER, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 665 - 675
  • [6] A POSITION-SENSITIVE GAMMA-RAY DETECTOR
    CHIAVASSA, E
    DELLACASA, G
    DEMARCO, N
    FERRERO, F
    MUSSO, MGA
    PICCOTTI, A
    VERCELLIN, E
    [J]. NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1989, 101 (05): : 805 - 814
  • [7] POSITION-SENSITIVE GAMMA-RAY DETECTORS USING RESISTIVE CHARGE DIVISION READOUT
    GERBER, MS
    MILLER, DW
    SCHLOSSER, PA
    STEIDLEY, JW
    DEUTCHMAN, AH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 182 - 187
  • [8] Employing thin HPGe detectors for gamma-ray imaging
    Vetter, K
    Mihailescu, L
    Ziock, K
    Burks, M
    Cork, C
    Fabris, L
    Hull, E
    Madden, N
    Pehl, R
    [J]. UNATTENDED RADIATION SENSOR SYSTEMS FOR REMOTE APPLICATIONS, 2002, 632 : 129 - 134
  • [9] Intelligent gamma-ray spectroscopy using 3-D position-sensitive detectors
    Lehner, CE
    He, Z
    Knoll, GE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 1090 - 1097
  • [10] Intelligent gamma-ray spectroscopy using 3D position-sensitive detectors
    Lehner, CE
    He, Z
    Knoll, GF
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 411 - 415