Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types

被引:22
|
作者
Sagheb, Keyvan [1 ]
Kumar, Vinay V. [1 ,3 ]
Azaripour, Adriano [2 ]
Walter, Christian [1 ]
Al-Nawas, Bilal [1 ]
Kaemmerer, Peer W. [4 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Oral & Maxillofacial Surg, Augustuspl 2, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Conservat Dent, Mainz, Germany
[3] Narayana Hlth, Mazumdar Shaw Med Ctr, Dept Head & Neck Surg, Bangalore, Karnataka, India
[4] Univ Rostock, Univ Med Ctr, Dept Oral & Maxillofacial Surg, Rostock, Germany
关键词
biomechanics; bone quality; bone implant interactions; piezosurgery; surgical techniques; ULTRASOUND TRANSMISSION VELOCITY; PRIMARY STABILITY; CUT BONE; SURGERY; QUALITY; OSSEOINTEGRATION; DENSITY; CHISEL;
D O I
10.1111/clr.12783
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveThe aim of this exvivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methodsFresh exvivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectroscopy. The primary implant stability after osteotomy was measured using resonance frequency analysis (RFA) and extrusion torque (ET). ANOVA with post hoc Tukey test was carried out to compare the values for the three different groups. ResultsThe UTV values strongly correlated with the density of the bone samples. There was a significant increase in time (threefold, P<0.05 [302s vs. 122s in cortical bone]) but no difference in the temperature for the piezo group (similar to 37 degrees C in cortical bone). Regardless of the osteotomy technique, there was a statistically significant increase in RFA and ET values in implants inserted in cancellous bone (RFA: piezo 77, drill 76; ET: piezo 22, drill 21), mixed bone (RFA: piezo 85, drill 86; ET: piezo 105, drill 61), and cortical bone (RFA: piezo 90, drill 87; ET piezo 184, drill 79) samples, respectively (P<0.05). In between the different osteotomy groups, there was no difference in the RFA values but significant higher ET values in mixed/cortical bone samples in favor for the piezosurgery group. ConclusionPiezosurgery and conventional implant bed drilling procedure do have similar mechanical outcomes regarding primary stability with high RFA values, but the preparation does need more time for piezosurgery group, so that piezosurgery might be a valuable tool in only very specific cases for implant bed preparation.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 50 条
  • [1] Implant primary stability depending on protocol and insertion mode — an ex vivo study
    Henning Staedt
    Peer W. Kämmerer
    Elisabeth Goetze
    Daniel G. E. Thiem
    Bilal Al-Nawas
    Diana Heimes
    [J]. International Journal of Implant Dentistry, 6
  • [2] Implant primary stability depending on protocol and insertion mode - an ex vivo study
    Staedt, Henning
    Kaemmerer, Peer W.
    Goetze, Elisabeth
    Thiem, Daniel G. E.
    Al-Nawas, Bilal
    Heimes, Diana
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [3] A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables
    Lee, Su-Young
    Piao, Chunmei
    Heo, Seong-Joo
    Koak, Jai-Young
    Lee, Joo-Hee
    Kim, Tae-Hyung
    Kim, Myung-Joo
    Kwon, Ho-Beom
    Kim, Seong-Kyun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 148 - 153
  • [4] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study
    Jacek Matys
    Rafał Flieger
    Gianluca Tenore
    Kinga Grzech-Leśniak
    Umberto Romeo
    Marzena Dominiak
    [J]. Lasers in Medical Science, 2018, 33 : 489 - 495
  • [5] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study
    Matys, Jacek
    Flieger, Rafa
    Tenore, Gianluca
    Grzech-Lesniak, Kinga
    Romeo, Umberto
    Dominiak, Marzena
    [J]. LASERS IN MEDICAL SCIENCE, 2018, 33 (03) : 489 - 495
  • [6] Piezosurgery versus Reciprocating Saw: Qualitative Comparison of the Morphology of Cutting Surfaces in Ex Vivo Human Bone
    Anesi, Alexandre
    Negrello, Sara
    Checchi, Marta
    Di Bartolomeo, Mattia
    Salvatori, Roberta
    Cavani, Francesco
    Palumbo, Carla
    Ferretti, Marzia
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (05):
  • [7] The effect of load on heat production, thermal effects and expenditure of time during implant site preparation - an experimental ex vivo comparison between piezosurgery and conventional drilling
    Stelzle, Florian
    Frenkel, Carsten
    Riemann, Max
    Knipfer, Christian
    Stockmann, Philipp
    Nkenke, Emeka
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : E140 - E148
  • [8] Different laser wavelengths comparison in the second-stage implant surgery: an ex vivo study
    Fornaini, Carlo
    Merigo, Elisabetta
    Vescovi, Paolo
    Bonanini, Mauro
    Antonietti, Walter
    Leoci, Luca
    Lagori, Giuseppe
    Meleti, Marco
    [J]. LASERS IN MEDICAL SCIENCE, 2015, 30 (06) : 1631 - 1639
  • [9] Different laser wavelengths comparison in the second-stage implant surgery: an ex vivo study
    Carlo Fornaini
    Elisabetta Merigo
    Paolo Vescovi
    Mauro Bonanini
    Walter Antonietti
    Luca Leoci
    Giuseppe Lagori
    Marco Meleti
    [J]. Lasers in Medical Science, 2015, 30 : 1631 - 1639
  • [10] Ex vivo gene therapy to produce bone using different cell types
    Musgrave, DS
    Bosch, P
    Lee, JY
    Pelinkovic, D
    Ghivizzani, SC
    Whalen, J
    Niyibizi, C
    Huard, J
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (378) : 290 - 305