Role of Internal Jugular Vein Ultrasound Measurements in the Assessment of Central Venous Pressure in Spontaneously Breathing Patients: A Systematic Review

被引:9
|
作者
Parenti, Nicola [1 ]
Scalese, Marco [2 ]
Palazzi, Carmela [1 ]
Agrusta, Federica [1 ]
Cahill, Jane [3 ]
Agnelli, Giancarlo [4 ]
机构
[1] Univ Modena & Reggio Emilia, Largo Pozzo 71, I-41125 Modena, MO, Italy
[2] Italian Natl Res Council IFC CNR, Inst Clin Physiol, Pisa, Italy
[3] Univ Leeds, Sch Healthcare, Leeds, W Yorkshire, England
[4] Univ Perugia, Cardiovasc Dis, Perugia, Italy
基金
英国惠康基金; 美国国家卫生研究院;
关键词
systematic review; internal jugular vein ultrasound; reliability; validity; INFERIOR VENA-CAVA; RIGHT ATRIAL PRESSURE; PREDICTING FLUID RESPONSIVENESS; ULTRASONOGRAPHIC MEASUREMENT; SONOGRAPHIC MEASUREMENTS; INTERRATER RELIABILITY; NONINVASIVE ESTIMATION; RESPIRATORY VARIATION; DIAMETER; VOLUME;
D O I
10.6705/j.jacme.201906_9(2).0001
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Few studies have tested the role of the internal jugular vein (IJV) ultrasonographic (US) diameters in the assessment of central venous pressure (CVP) in spontaneously breathing patients. No review or meta-analysis is currently available on the role of IJV assessment in this setting. The aim of this systematic review is to check the reliability and accuracy of IJV US diameters in predicting CVP and to evaluate its correlation with CVP in spontaneously breathing patients. Methods: This systematic review was based on the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. We included studies on the accuracy and reliability of the UV ultrasound measures and studies exploring its correlation with CVP in adult spontaneously breathing patients. The studies' report quality was assessed by Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 scales. Results: A total of five studies was eligible for final analysis. The studies on IJV ultrasound measures showed a good quality in reporting. The anterior-posterior diameter maximum of UV (AP-IJV Dmax) showed the best correlation with the CVP with a good inter-rater reliability and validity in predicting CVP. All measures showed good inter-rater reliability and validity in predicting CVP, but only the AP-IJV Dmax showed good correlation with CVP. Conclusions: The AP-IJV Dmax could be a potential surrogate of CVP because of its good reliability and validity in predicting CVP value and its fair-moderate correlation with CVP. Anyway, further research should confirm these conclusions.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 50 条
  • [1] Ultrasound imaging and central venous pressure in spontaneously breathing patients: a comparison of ultrasound-based measures of internal jugular vein and inferior vena cava
    Parenti, Nicola
    Bastiani, Luca
    Tripolino, Cesare
    Bacchilega, Igor
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2022, 54 (02) : 150 - 155
  • [2] Estimation of central venous pressure by ultrasound of the internal jugular vein
    Lipton, B
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2000, 18 (04): : 432 - 434
  • [3] Correlation of sonographic measurements of the internal jugular vein with central venous pressure
    Donahue, Sean P.
    Wood, Joseph P.
    Patel, Bhavesh M.
    Quinn, James V.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (07): : 851 - 855
  • [4] Diagnostic accuracy of internal jugular vein ultrasound in quantification of the central venous pressure for hemodialysis patients
    Ahmed Abd Alrahman Baz
    Amro Abdulrahim Ibrahim
    Hussein Saeed El-Fishawy
    Abo El-Magd Mohamed Al-Bohy
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [5] Diagnostic accuracy of internal jugular vein ultrasound in quantification of the central venous pressure for hemodialysis patients
    Baz, Ahmed Abd Alrahman
    Ibrahim, Amro Abdulrahim
    El-Fishawy, Hussein Saeed
    Al-Bohy, Abo El-Magd Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [6] Central venous pressure estimation with force-coupled ultrasound of the internal jugular vein
    Alex Jaffe
    Ivan Goryachev
    Charles Sodini
    Brian W. Anthony
    Scientific Reports, 13
  • [7] Central venous pressure estimation with force-coupled ultrasound of the internal jugular vein
    Jaffe, Alex
    Goryachev, Ivan
    Sodini, Charles
    Anthony, Brian W.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [8] The sensitivity and specificity of ultrasound estimation of central venous pressure using the internal jugular vein
    Siva, Brian
    Hunt, Austin
    Boudville, Neil
    JOURNAL OF CRITICAL CARE, 2012, 27 (03)
  • [9] Could internal jugular vein ultrasound be useful in the assessment of patients with heart failure? A systematic review
    Parenti, Nicola
    Palazzi, Carmela
    Parenti, Matilde
    D'Addato, Sergio
    ITALIAN JOURNAL OF MEDICINE, 2024, 18 (02)
  • [10] Ultrasonographic assessment of the internal jugular vein for the estimation of central venous pressure in hemodialysis patients: A preliminary study
    Kerleroux, Basile
    Pasco, Jeremy
    Dupuis, Mathieu
    Eustache, Marine
    Lemrabott, Ahmed
    Jouzel, Charlotte
    Albert, Catherine
    Janot, Kevin
    Morel, Baptiste
    Pruna, Andre
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (04) : 253 - 258