Effects of Impression Material, Impression Tray Type, and Type of Partial Edentulism on the Fit of Cobalt-Chromium Partial Denture Frameworks on Initial Clinical Insertion: A Retrospective Clinical Evaluation

被引:4
|
作者
Baig, Mirza Rustum [1 ]
Akbar, Jaber Hussain [1 ]
Qudeimat, Muawia [2 ]
Omar, Ridwaan [1 ]
机构
[1] Kuwait Univ, Fac Dent, Dept Restorat Sci Prosthodont, Kuwait, Kuwait
[2] Kuwait Univ, Fac Dent, Dept Dev & Prevent Sci, Kuwait, Kuwait
关键词
D O I
10.11607/ijp.5495
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the effects of impression material, impression tray type, and type of partial edentulism (ie, Kennedy class) on the accuracy of fit of cobalt-chromium (Co-Cr) partial removable dental prostheses (PRDP) in terms of the number of fabricated frameworks required until the attainment of adequate fit. Materials and Methods: Electronic case documentations of 120 partially edentulous patients provided with Co-Cr PRDP treatment for one or both arches were examined. Statistical analyses of data were performed using analysis of variance and Tukey honest significant difference test to compare the relationships between the different factors and the number of frameworks that needed to be fabricated for each patient (alpha = .05). Results: Statistical analysis of data derived from 143 records (69 maxillary and 74 mandibular) revealed no significant correlation between impression material, tray type, or Kennedy class and the number of construction attempts for the pooled or individual arch data (f >= .05). Conclusion: In PRDP treatment, alginate can be chosen as a first-choice material, and metal stock trays can be a preferred option for making final impressions to fabricate Co-Cr frameworks.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 6 条
  • [1] Fit and Retention of Cobalt-Chromium Removable Partial Denture Frameworks Fabricated with Selective Laser Melting
    Rues, Stefan
    Tasaka, Akinori
    Fleckenstein, Isabella
    Yamashita, Shuichiro
    Rammelsberg, Peter
    Boehm, Sophia
    Schwindling, Franz Sebastian
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (08)
  • [2] Comparative Evaluation of the Effects of Implant Position, Impression Material, and Tray Type on Implant Impression Accuracy
    Gokcen-Rohlig, Bilge
    Ongul, Deger
    Sancakli, Erkan
    Sermet, Bulent
    IMPLANT DENTISTRY, 2014, 23 (03) : 283 - 288
  • [3] An Investigation into the Accuracy of Two Currently Available Dental Impression Materials in the Construction of Cobalt-Chromium Frameworks for Removable Partial Dentures
    Dubal, Rajesh Kumar
    Friel, Tim
    Dtaylor, Philip
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2015, 23 (01): : 16 - 28
  • [4] Association of fit of partial denture metal framework with various framework design features using alginate as a final impression material: A prospective clinical study
    Baig, Mirza Rustum
    Omar, Ridwaan
    JOURNAL OF DENTISTRY, 2021, 107
  • [5] A clinical evaluation of cobalt-chromium metal-ceramic fixed partial dentures an crowns: A three- to seven-year retrospective study
    Eliasson, Alf
    Arnelund, Carl-Fredrik
    Johansson, Anders
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (01): : 6 - 16
  • [6] A Clinical Retrospective Study of Distal Extension Removable Partial Denture with Implant Surveyed Bridge or Stud Type Attachment
    Bae, Eun-Bin
    Kim, Seong-Jong
    Choi, Jae-Won
    Jeon, Young-Chan
    Jeong, Chang-Mo
    Yun, Mi-Jung
    Lee, So-Hyoun
    Huh, Jung-Bo
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017