Novel Uric Acid Sensor Based on Enzyme Electrode Modified by ZnO Nanoparticles and Multiwall Carbon Nanotubes

被引:30
|
作者
Wang, Yiting [2 ]
Yu, Lei [2 ]
Zhu, Ziqiang [1 ]
Zhang, Jian [1 ]
Zhu, Jianzhong [1 ]
机构
[1] E China Normal Univ, Sch Informat Sci & Technol, Shanghai 200062, Peoples R China
[2] E China Normal Univ, Adv Res Ctr NBIC Integrated Drug Discovery & Dev, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
Biosensors; multiwall carbon nanotubes; uric acid sensor; uricase; ZnO nanoparticles; GOLD NANOPARTICLES; GLUCOSE-OXIDASE; BIOSENSOR; IMMOBILIZATION;
D O I
10.1080/00032710802677159
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we report the development of a highly sensitive and stable uric acid sensor based on the synergic action of multiwalled carbon nanotubes (MWNTs) and ZnO nanoparticles. MWNTs were first cast on pyrolytic graphite (PG) wafers. ZnO nanoparticles were then decorated onto the negatively charged MWNTs via the Vapor Liquid Solid (VLS) growth. Uricase was immobilized on the ZnO nanoparticles surface because of their large differences in the isoelectric point (IEP). Last, a cationic polydiallyldimethylammonium chloride (PDDA) layer was coated onto the uricase-contained ZnO nanoparticle layer and resulted in the PDDA/uricase/ZnO/MWNTs multilayer structure. The unique multilayer structure provides a favorable microenvironment to keep the bioactivity of uricase, which led to rapid amperometric response toward uric acid. Amperometric detection of uric acid was carried out at 320mV (vs. SCE) in 0.05mol/L (M) phosphate buffer solution (pH 6.8). For the sensor, a wide linear response range of 5.0M to 1mM with a linear sensitivity of 393mA cm-2M-1, a detection limit of 2.0M (3), and a long-term stability of 160 days can be obtained by using differential pulse voltammetry (DPV). Testing results in human urine obtained from the sensors were also compared with the data obtained by spectrometry. For five samples with different concentrations of urine, the relative deviations between them were smaller than 3.8%. The recovery was between 96.5 and 104.0%.
引用
收藏
页码:775 / 789
页数:15
相关论文
共 50 条
  • [1] A novel L-lactate sensor based on enzyme electrode modified with ZnO nanoparticles and multiwall carbon nanotubes
    Wang, Y. T.
    Yu, L.
    Wang, J.
    Lou, L.
    Du, W. J.
    Zhu, Z. Q.
    Peng, H.
    Zhu, J. Z.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (01) : 8 - 12
  • [2] A Novel L-Lactate Sensor Based on Enzyme Electrode Modified with ZnO Nanoparticles and Multiwall Carbon Nanotubes
    Wang, Y. T.
    Bao, Y. J.
    Lou, L.
    Li, J. J.
    Du, W. J.
    Zhu, Z. Q.
    Peng, H.
    Zhu, J. Z.
    [J]. 2010 IEEE SENSORS, 2010, : 33 - 37
  • [3] A uric acid sensor based on electrodeposition of nickel hexacyanoferrate nanoparticles on an electrode modified with multi-walled carbon nanotubes
    Bin Fang
    Yuehua Feng
    Guangfeng Wang
    Cuihong Zhang
    Aixia Gu
    Min Liu
    [J]. Microchimica Acta, 2011, 173 : 27 - 32
  • [4] A uric acid sensor based on electrodeposition of nickel hexacyanoferrate nanoparticles on an electrode modified with multi-walled carbon nanotubes
    Fang, Bin
    Feng, Yuehua
    Wang, Guangfeng
    Zhang, Cuihong
    Gu, Aixia
    Liu, Min
    [J]. MICROCHIMICA ACTA, 2011, 173 (1-2) : 27 - 32
  • [5] Cefixime detection by a novel electrochemical sensor based on glassy carbon electrode modified with surface imprinted polymer/multiwall carbon nanotubes
    Karimian, N.
    Gholivand, M. B.
    Malekzadeh, Gh.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 771 : 64 - 72
  • [6] Enantioselective Recognition of Mandelic Acid Based on Hemoglobin and Multiwall Carbon Nanotubes Modified Electrode
    Zhang, Qing
    Wang, Yonghua
    Han, Qian
    Guo, Liju
    Huang, Yihan
    Fu, Yingzi
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (11) : B213 - B217
  • [7] An electrochemical sensor for creatinine based on carbon nanotubes/folic acid/silver nanoparticles modified electrode
    Fekry, A. M.
    Abdel-Gawad, S. A.
    Tammam, R. H.
    Zayed, M. A.
    [J]. MEASUREMENT, 2020, 163
  • [8] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid at Pt Nanoparticles Decorated Multiwall Carbon Nanotubes Modified GCE
    Dursun, Zekerya
    Gelmez, Buket
    [J]. ELECTROANALYSIS, 2010, 22 (10) : 1106 - 1114
  • [9] Sodium dodecyl sulfate modified carbon nanotubes paste electrode as a novel sensor for the simultaneous determination of dopamine, ascorbic acid, and uric acid
    Manjunatha, Jamballi G.
    Deraman, Mohamad
    Basri, Nur Hamizah
    Nor, Najah Syahirah Mohd
    Abu Talib, Ibrahim
    Ataollahi, Narges
    [J]. COMPTES RENDUS CHIMIE, 2014, 17 (05) : 465 - 476
  • [10] Electrochemical Sensor Based on Single-Walled Carbon Nanotubes-Modified Gold Electrode for Uric Acid Detection
    Kurniawan, Fredy
    Al Kiswiyah, Nur Shofwah
    Madurani, Kartika A.
    Tominaga, Masato