An investigation on the radiation sensitivity of DNA conformations to 60Co gamma rays by using Geant4 toolkit

被引:15
|
作者
Semsarha, F. [1 ]
Goliaei, B. [1 ]
Raisali, G. [2 ]
Khalafi, H. [2 ]
Mirzakhanian, L. [3 ]
机构
[1] Univ Tehran, Inst Biochem & Biophys IBB, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Radiat Applicat Res Sch, Tehran, Iran
[3] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
关键词
Geant4; DNA conformation; DNA damage; Microdosimetric quantities; Radiation sensitivity; TRACK STRUCTURE CALCULATIONS; MONTE-CARLO-SIMULATION; LOW-ENERGY ELECTRONS; X-RAYS; STRAND BREAKS; LIQUID WATER; CROSS-SECTIONS; TARGET MODEL; IN-VITRO; A-DNA;
D O I
10.1016/j.nimb.2014.01.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To investigate the impact of conformational properties of genetic material of living cells on radiation-induced DNA damage, single strand breaks (SSB), double strand breaks (DSB) and some microdosimetric quantities of A, B and Z-DNA conformations caused by Co-60 gamma rays, have been calculated. Based on a previous B-DNA geometrical model, models of A and Z forms have been developed. Simple 34 base pairs segments of each model repeated in high number and secondary electron spectrum of Co-60 gamma rays have been simulated in a volume of a typical animal cell nucleus. All simulations in this study have been performed by using the Geant4 (GEometry ANd Tracking 4)-DNA extension of the Geant4 toolkit. The results showed that, B-DNA has the lowest yield of simple strand breaks with 2.23 x 10(-10) Gy(-1) Da(-1) and 1.0 x 10(-11) Gy(-1) Da(-1) for the SSB and DSB damage yield, respectively. The A-DNA has the highest SSB yield with 3.59 x 10(-1) Gy(-1) Da(-1) and the Z-DNA has the highest DSB yields with 1.8 x 10(-11) Gy(-1) Da(-1). It has been concluded that there is a direct correlation between the hit probability, mean specific imparted energy and SSB yield in each model of DNA. Moreover, there is a direct correlation between the DSB yield and both the mean lineal energy and topological characteristics of each model. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [1] Calculation of direct effects of 60Co gamma rays on the different DNA structural levels: A simulation study using the Geant4-DNA toolkit
    Tajik, Marjan
    Rozatian, Amir S. H.
    Semsarha, Farid
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 346 : 53 - 60
  • [2] Cytogenetic analysis of 60Co γ-radiation-induced chromosome damage and simulations using the Geant4 Monte Carlo toolkit
    Fourie, H.
    Newman, R. T.
    Slabbert, J. P.
    Beukes, P.
    PROCEEDINGS OF SAIP2013: THE 58TH ANNUAL CONFERENCE OF THE SOUTH AFRICAN INSTITUTE OF PHYSICS, 2013, : 248 - 253
  • [3] Application of a GEANT4 Simulation to a 60Co Therapy Unit
    Shin, Jae Won
    Hong, Seung-Woo
    Lee, Cung-Il
    Suh, Tae-Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (01) : 12 - 19
  • [4] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Chen, Jun-Liang
    Yun, Su-Jun
    Dong, Tie-Kuang
    Ren, Zhong-Zhou
    Zhang, Xiao-Ping
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (01)
  • [5] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Jun-Liang Chen
    Su-Jun Yun
    Tie-Kuang Dong
    Zhong-Zhou Ren
    Xiao-Ping Zhang
    Nuclear Science and Techniques, 2022, 33
  • [6] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Jun-Liang Chen
    Su-Jun Yun
    Tie-Kuang Dong
    Zhong-Zhou Ren
    Xiao-Ping Zhang
    NuclearScienceandTechniques, 2022, 33 (01) : 122 - 132
  • [7] RADIATION QUALITY OF TRITIUM: A COMPARISON WITH 60Co GAMMA RAYS
    Chen, Jing
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (03) : 372 - 375
  • [8] Simulation of ultrasoft X-rays induced DNA damage using the Geant4 Monte Carlo toolkit
    Tajik, Marjan
    Rozatian, Amir S. H.
    Semsarha, Farid
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 342 : 258 - 265
  • [9] Impact of Cobalt-60 Gamma Radiation Source on Electronic Devices using Geant4
    Zakaria, Abd Hafiz
    Mustafah, Yasir M.
    Abdullah, Jaafar
    Khair, Nahrul
    Ithnin, Hanafi
    2016 IEEE INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS (IRIS 2016), 2017, 105 : 40 - 45
  • [10] Proton Therapy Range Verification Using Prompt Gamma Rays: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2013, 40 (06)