On-line PD detection in XLPE power cable based on fractal theory

被引:0
|
作者
Luo, Junhua [1 ]
Ten, Letian [2 ]
Zhu, Haigang [3 ]
机构
[1] Wuhan High Voltage Res Inst, 143 Luoyu Rd, Wuhan 430074, Hubei, Peoples R China
[2] Shanghai Power Supply Co Ltd, Shanghai 200122, Peoples R China
[3] East Shanghai Power Supply Co Ltd, Shanghai 200122, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Based on variety of fractal dimension scale and principle of self-similarity, this paper presents a new digital analysis system for partial discharge (PD) signal detecting, recognizing and processing. Aplifleation of fractal character calculating, detecting PD pulse signal of XLPE power cable approach very high frequency (VHF) using high-frequency and wide-band electromagnetism coupling is able to restrain noise interfering and pick up PD signal key eigenvalue effectively. The technique for on-fine detection of partial discharge in XLPE power cable have been improved in this paper.
引用
收藏
页码:592 / +
页数:2
相关论文
共 50 条
  • [1] Recent experiences with on-line PD testing of MV XLPE and EPR cable
    Fenger, Mark
    Sedding, Howard
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 42 - +
  • [2] The study of on-line PD detector in power cable
    Wang, W
    Zhao, S
    Cang, B
    Liu, EH
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 177 - 180
  • [3] Study of on-line monitoring of XLPE power cable by earth line current method
    Luo, Huayu
    Guan, Genzhi
    Yi, Xiaoyu
    Gaodianya Jishu/High Voltage Engineering, 2005, 31 (11): : 63 - 65
  • [4] On-line partial discharge monitor system of XLPE power cable based on virtual instrument
    Cheng, YH
    Chen, XL
    Zhang, SF
    Lv, YH
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 207 - 210
  • [5] Development of on-line partial discharge monitor system for XLPE power cable
    Tang, Zhong
    Zou, Yunping
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 640 - +
  • [6] Comparison of on-line partial discharge detection methods for XLPE cable joints
    Williams, GM
    Lewin, PL
    Davies, AE
    Sutton, SJ
    Swingler, SG
    QRM 2002: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, AND MAINTENANCE, 2002, : 319 - 322
  • [7] Study of on-line Monitoring of XLPE Cable's Device and Assessment by Fuzzy Theory
    Ye, Juwei
    Qin, Qinghuan
    Luo, Chen
    Li, Shufang
    Su, Kai
    Bao, Yineng
    Zhang, Zhanglong
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION (IFEEA 2015), 2016, 54 : 96 - 105
  • [8] On-line PD System and PD Locator for XLPE Cables
    Sakoda, Tatsuya
    Yamasaki, Yuhei
    Nakanose, Soichiro
    Hayashi, Noriyuki
    Miyake, Takuma
    Miyagawa, Koji
    Kawano, Wataru
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 222 - 225
  • [9] On-line time domain reflectometry measurements of temperature variations of an XLPE power cable
    Dubickas, V.
    Edin, H.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 47 - 50
  • [10] Analysis of 3-d partial discharge patterns in XLPE power cable based on fractal theory
    Luo, JH
    Zhu, HG
    Jiang, F
    Yuan, H
    CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 116 - 118