Synthetic aperture imaging using a semi-analytic model for the transmit beams

被引:0
|
作者
Nikolov, Svetoslav Ivanov [1 ]
Hansen, Jens Munk [1 ]
机构
[1] BK Ultrasound, DK-2730 Herlev, Denmark
关键词
D O I
10.1109/ULTSYM.2015.0073
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Many modern high-end scanners use some form for coherent synthesis of image lines by combining beams acquired with different transmissions such as retrospective dynamic transmit focusing (Acuson / Siemens), nSIGHT (Philips), and Zone imaging (Zonare). To synthesize the final image, beams acquired by different transmissions are coherently summed. The inter-beam delays and interpolation function vary across implementations. There are two major strategies described in literature to calculate the inter-beam delays and to uniformly focus both transmit and receive beams throughout the field of view - using virtual sources, and by applying spatial matched filtration. The virtual source model is precise, when the transmit is either strongly focused (f-number 1, 2) or images are formed using circular or spherical waves. The model becomes inadequate for higher f-numbers. The spatial matched filtration can be used both for strongly and weakly focused transmissions, but requires the measurement and storage of the response of point targets within the limits of the transmit beam. This paper presents a semi-analytic model for the transmitted field, which can be applied to synthetic transmit imaging. The model is more precise than the virtual source concept, does not require the measurement of the transmit field as matched filtration methods do, and can be applied to both strongly and weakly focused transmissions. Furthermore, the model is applicable to tissue harmonic and contrast enhanced ultrasound imaging. The paper presents the development of the model using the principles of diffraction, and its validation using computer simulations and measurements on a phantom.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Synthetic aperture imaging using a semi-analytic model for the transmit beams
    Hansen, Jens Munk
    Nikolov, Svetoslav Ivanov
    MEDICAL IMAGING 2015: ULTRASONIC IMAGING AND TOMOGRAPHY, 2015, 9419
  • [2] Investigation on synthetic aperture imaging using focused transmit beams for cardiac ultrasonography
    Sugioka, Kotaro
    Mozumi, Michiya
    Omura, Masaaki
    Nagaoka, Ryo
    Hasegawa, Hideyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2023, 62 (SJ)
  • [3] Investigation on synthetic aperture imaging using focused transmit beams for cardiac ultrasonography
    Graduate School of Science and Engineering, University of Toyama, Toyama
    930-8555, Japan
    不详
    930-8555, Japan
    Jpn. J. Appl. Phys., 1600, SJ
  • [4] SEMI-ANALYTIC METHODS FOR ROTATING TIMOSHENKO BEAMS
    STAFFORD, RO
    GIURGIUTIU, V
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 1975, 17 (11-1) : 719 - 727
  • [5] Synthetic Transmit Aperture in Ultrasound Imaging
    Trots, Ihor
    Nowicki, Andrzej
    Lewandowski, Marcin
    ARCHIVES OF ACOUSTICS, 2009, 34 (04) : 685 - 695
  • [6] Multielement synthetic transmit aperture imaging using temporal encoding
    Gammelmark, KL
    Jensen, JA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (04) : 552 - 563
  • [7] A semi-analytic model for oligarchic growth
    Chambers, J
    ICARUS, 2006, 180 (02) : 496 - 513
  • [8] Semi-analytic AMR element model
    Teyber, R.
    Trevizoli, P. V.
    Christiaanse, T. V.
    Govindappa, P.
    Niknia, I.
    Rowe, A.
    APPLIED THERMAL ENGINEERING, 2018, 128 : 1022 - 1029
  • [9] A semi-analytic model of halo dynamics
    Taylor, JE
    Babul, A
    NEW ERA IN COSMOLOGY, 2002, 283 : 334 - 336
  • [10] Synthetic transmit aperture imaging using orthogonal Golay coded excitation
    Chiao, RY
    Thomas, LJ
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1677 - 1680