Routine microbiological sampling and analysis of ground meat for quality control purposes - practical experience and statistical conclusions

被引:0
|
作者
Gerhardt, T [1 ]
Hildebrandt, G [1 ]
机构
[1] Free Univ Berlin, Fachbereich Vet Med, Inst Lebensmittelhyg, D-14163 Berlin, Germany
来源
ARCHIV FUR LEBENSMITTELHYGIENE | 2000年 / 51卷 / 01期
关键词
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The microbiological status of ground beef was routinely assessed at two production facilities over a period of at least one year. Five re-plicate samples were tested per day in accordance with European meat hygiene directives. In light of the high workload it was of great interest to decide whether the sample number could be reduced by combining the 5 single samples per lot to a pool sample without causing a significance loss of information. Concerning the "aerobic total plate count" as the main criterion the findings showed that: Analysing a pool sample and using 3m reads in 129 of 131 lots of producer A to the same decision (acceptance/rejection) as 5 random samples in connection with the official 3-class-sampling plan (3(m)/c(m) = 2; M/c(M) = 0). In the case of producer B there have been 3 opposite decisions in 319 lots despite of a very heterogeneous structure of the microbiological counts. More defective lots were observed on Mondays. No other trends could be observed. Obviously the microbiological results of 5 samples/day are only used for documentation and not for corrective actions or improvement of the hygienic status, ii there are no severe objections against the bacteriological quality. Because the relatively poor information does not justify the analytical workload a modification of the official sampling plan is proposed: Following the principles of moving sum procedure the 5 random samples of minced meat per lot are combined to a pool sample and tested against the limit 3m as long as no more than 2 plate counts exceed the limit 3m in the last 11 days of production.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 10 条
  • [1] Quality control of routine sampling in chemical analysis
    Ramsey, M. H.
    ANALYTICAL METHODS, 2012, 4 (06) : 1482 - 1483
  • [2] Handheld NIRS analysis for routine meat quality control: Database transfer from at-line instruments
    Zamora-Rojas, E.
    Perez-Marin, D.
    De Pedro-Sanz, E.
    Guerrero-Ginel, J. E.
    Garrido-Varo, A.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2012, 114 : 30 - 35
  • [3] Application of multivariate statistical analysis to quality control systems. Relevance of the stages in poultry meat production
    Escudero-Gilete, M. L.
    Gonzalez-Miret, M. L.
    Heredia, F. J.
    FOOD CONTROL, 2014, 40 : 243 - 249
  • [4] ROUTINE QA/QC TESTING AND AUTOMATED STATISTICAL QUALITY-CONTROL OF THERMOSET MATERIALS USING DIELECTRIC ANALYSIS
    SENTURIA, TA
    SHEPARD, DD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 139 - PMSE
  • [5] ROUTINE QA-QC TESTING AND AUTOMATED STATISTICAL QUALITY-CONTROL OF THERMOSET MATERIALS USING DIELECTRIC ANALYSIS
    SHEPARD, D
    SENTURIA, T
    AMERICAN LABORATORY, 1993, 25 (17) : 38 - &
  • [6] ROUTINE QUANTITATIVE GAS-CHROMATOGRAPHIC ANALYSIS OF PESTICIDES FOR QUALITY AND PRODUCTION CONTROL USING CAPILLARY COLUMNS AND ON-COLUMN (SYRINGE) SAMPLING
    PROSKE, MG
    BENDER, M
    SCHOMBURG, G
    HUBINGER, E
    JOURNAL OF CHROMATOGRAPHY, 1982, 240 (01): : 95 - 106
  • [7] Practical application of the sigma-metric run size nomogram for multistage bracketed statistical quality control analysis of eight enzymes
    Zeng, Yuping
    He, He
    Qin, Ken
    Zhang, Mei
    An, Zhenmei
    Huang, Hengjian
    CLINICA CHIMICA ACTA, 2019, 492 : 57 - 61
  • [8] BIAS TO ROUTINE SEMEN ANALYSIS BY UNCONTROLLED CHANGES IN LABORATORY ENVIRONMENT - DETECTION BY LONG-TERM SAMPLING OF MONTHLY MEANS FOR QUALITY-CONTROL
    KNUTH, UA
    NEUWINGER, J
    NIESCHLAG, E
    INTERNATIONAL JOURNAL OF ANDROLOGY, 1989, 12 (05): : 375 - 383
  • [9] Time-series analysis statistical techniques for quality control:: A practical example using the cortisol assay performed with ACS 180 Plus®.
    Genta, VM
    Daugherty, R
    Ordonez, L
    Ascher, KS
    Judge, K
    CLINICAL CHEMISTRY, 2000, 46 (06) : A118 - A119
  • [10] COMPARISON OF SHORT TERM IMPRECISIONS OF RAPIDLAB 400 AND RADIOMETER 800 BLOOD GAS SYSTEMS DERIVED FROM THE STATISTICAL ANALYSIS OF ROUTINE QUALITY CONTROL DATA
    Cembrowski, G.
    Tran, D.
    Wiley, C.
    Halvorson, T.
    Schifman, R.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S716 - S716