Maternal serum analyte levels in pregnancies with fetal Down syndrome resulting from translocations

被引:7
|
作者
Saller, DN
Canick, JA
Kellner, LH
Rose, NC
Garza, J
French, CA
Mooney, RA
机构
[1] UNIV ROCHESTER,STRONG MEM HOSP,SCH MED & DENT,DEPT PEDIAT,ROCHESTER,NY 14642
[2] UNIV ROCHESTER,STRONG MEM HOSP,SCH MED & DENT,DEPT PATHOL,ROCHESTER,NY 14642
[3] HOSP UNIV PENN,DEPT OBSTET & GYNECOL,PHILADELPHIA,PA 19104
[4] BROWN UNIV,WOMEN & INFANTS HOSP,DEPT PATHOL,PROVIDENCE,RI 02912
[5] MONTEFIORE MED CTR,ALBERT EINSTEIN COLL MED,DEPT OBSTET & GYNECOL,BRONX,NY 10467
关键词
alpha-fetoprotein; maternal serum screening; Down syndrome; Robertsonian translocation;
D O I
10.1016/S0002-9378(97)70287-4
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Our purpose was to determine whether pregnancies affected by fetal Down syndrome resulting from Robertsonian translocations are associated with second-trimester maternal serum analyte levels different from those resulting from fetal trisomy 21. STUDY DESIGN: Pregnancies with Down syndrome caused by Robertsonian translocations were identified through the cytogenetics laboratories at the participating institutions. Those with maternal serum screening values between 15 and 20 weeks were evaluated. RESULTS: Eleven cases of fetal Down syndrome caused by Robertsonian translocations were identified. The median alpha-fetoprotein, unconjugated estriol, and human chorionic gonadotropin levels were 0.68, 0.67, and 2.83 multiples of the median, respectively. These analyte levels are similar to those for fetal trisomy 21. CONCLUSIONS: These data suggest that Down syndrome resulting from either Robertsonian translocations or trisomy 21 will be detected in a similar percentage of cases because the second-trimester maternal serum analyte levels are similar.
引用
收藏
页码:879 / 881
页数:3
相关论文
共 50 条
  • [42] Down syndrome and cell-free fetal DNA in archived maternal serum
    Lee, T
    LeShane, ES
    Messerlian, GM
    Canick, JA
    Farina, A
    Heber, WW
    Bianchi, DW
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2002, 187 (05) : 1217 - 1221
  • [43] MATERNAL SERUM UNCONJUGATED ESTRIOL AND HUMAN CHORIONIC-GONADOTROPIN LEVELS IN TWIN PREGNANCIES - IMPLICATIONS FOR SCREENING FOR DOWN-SYNDROME
    WALD, N
    CUCKLE, H
    WU, TS
    GEORGE, L
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (09): : 905 - 908
  • [44] High levels of maternal serum human chorionic gonadotropin in Down syndrome pregnancies: The possible role of a transcription factor on chromosome 21
    Goshen, R
    Gonik, B
    Ariel, I
    Weiss, Y
    de-Groot, N
    Hochberg, A
    FETAL DIAGNOSIS AND THERAPY, 1999, 14 (02) : 106 - 111
  • [45] Fetal and maternal levels of lipid peroxides in term pregnancies
    Rogers, MS
    Mongelli, M
    Tsang, KH
    Wang, CC
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1999, 78 (02) : 120 - 124
  • [46] ABNORMAL MATERNAL SERUM CHORIONIC-GONADOTROPIN LEVELS IN PREGNANCIES WITH FETAL CHROMOSOME-ABNORMALITIES
    BOGART, MH
    PANDIAN, MR
    JONES, OW
    PRENATAL DIAGNOSIS, 1987, 7 (09) : 623 - 630
  • [47] Maternal serum alpha-fetoprotein levels in pregnancies with fetal cleft lip and palate.
    Deering, S
    Bienstock, J
    Blakemore, K
    Hueppchen, N
    AMERICAN JOURNAL OF HUMAN GENETICS, 2001, 69 (04) : 660 - 660
  • [48] Second trimester levels of maternal serum inhibin A in pregnancies affected by fetal neural tube defects
    Lambert-Messerlian, GM
    Palomaki, GE
    Canick, JA
    PRENATAL DIAGNOSIS, 2000, 20 (08) : 680 - 682
  • [49] The impact of fresh versus frozen-thawed embryos on maternal serum analyte levels in IVF singleton and twin pregnancies
    Alexandra Peyser
    Moti Gulersen
    David Krantz
    Xueying Li
    Eran Bornstein
    Burton Rochelson
    Christine Mullin
    Randi Goldman
    Journal of Assisted Reproduction and Genetics, 2024, 41 : 473 - 481
  • [50] SPONTANEOUS FETAL-MATERNAL HEMORRHAGE RESULTING IN HYDROPS AND ELEVATED MATERNAL SERUM ALPHA-FETOPROTEIN LEVELS
    GILBERT, WM
    SCIOSCIA, AL
    JOURNAL OF ULTRASOUND IN MEDICINE, 1991, 10 (11) : 645 - 648