3D Intraventricular Flow Mapping from Colour Doppler Images and Wall Motion

被引:0
|
作者
Gomez, Alberto [1 ]
de Vecchi, Adelaide [1 ]
Pushparajah, Kuberan [1 ]
Simpson, John [1 ]
Giese, Daniel [1 ]
Schaeffter, Tobias [1 ]
Penney, Graeme [1 ]
机构
[1] Kings Coll London, Div Imaging Sci, London WC2R 2LS, England
关键词
Colour Doppler Echocardiography; 3D Velocity Reconstruction; Flow Patterns; Cardiac Motion; Multiple Views; and Registration;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We propose a new method to recover 3D time-resolved velocity vectors within the left ventricle (LV) using a combination of multiple registered 3D colour Doppler images and LV wall motion. Incorporation of wall motion, calculated from 3D B-Mode images, and the use of a multi-scale reconstruction framework allow recovery of 3D velocity over the entire ventricle, even in regions where there is little or no Doppler data. Our method is tested on the LV of a paediatric patient and is compared to 2D and 3D flow Magnetic Resonance Imaging (MRI). Use of wall motion information increased stroke volume accuracy by 14%, and enabled full 3D velocity mapping within the ventricle. Velocity distribution showed good agreement with respect to MRI, and vortex formation during diastole was successfully reconstructed.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 50 条
  • [1] Intraventricular vector flow mapping 3-D by triplane Doppler echocardiography
    Vixege, F.
    Courand, P. Y.
    Blanc-Benon, P.
    Mendez, S.
    Nicoud, F.
    Vray, D.
    Garcia, D.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 : S300 - S302
  • [2] Analysis of cardiac wall motion from multi-phase 3D images
    Xu, Zhen-hai
    Wang, W. -L.
    Guan, Qiu
    Chen, S. Y.
    TENCON 2006 - 2006 IEEE REGION 10 CONFERENCE, VOLS 1-4, 2006, : 1375 - +
  • [3] The effect of the vessel wall motion on color flow mapping images
    Zhang, Qinghui
    Zhang, Yufeng
    Zhou, Yi
    Gao, Lian
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON MEASUREMENT, INSTRUMENTATION AND AUTOMATION (ICMIA 2016), 2016, 138 : 361 - 365
  • [4] Estimation of wall motion from 3D echocardiography
    Alessandro, S
    Federico, F
    Claudio, L
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 2311 - 2313
  • [5] 3D Articulated motion estimation from images
    Zhang, XY
    Liu, YC
    2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 1, PROCEEDINGS, 2005, : 308 - 314
  • [6] Transforming 3D colour histograms of images
    Morovic, J
    Sun, PL
    CGIV'2002: FIRST EUROPEAN CONFERENCE ON COLOUR IN GRAPHICS, IMAGING, AND VISION, CONFERENCE PROCEEDINGS, 2002, : 104 - 108
  • [7] Noninvasive assessment of systolic intraventricular pressure gradient using 2-D colour Doppler images
    Donal, E
    Coisne, D
    Bergeron, C
    Thibault, H
    Loufouat, J
    Blouin, P
    Ovize, M
    Derumeau, G
    EUROPEAN HEART JOURNAL, 2004, 25 : 504 - 504
  • [8] Colour Doppler ultrasound mapping of chest wall lesions
    Görg, C
    Bert, T
    Görg, K
    Heinzel-Gutenbrunner, M
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (928): : 303 - 307
  • [9] Design Flow of Motion Based Single Camera 3D Mapping
    Yang, Guojun
    Zhou, Zhen
    Gonnot, Thomas
    Saniie, Jafar
    2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY (EIT), 2015, : 341 - 345
  • [10] Conformal mapping of carotid vessel wall and plaque thickness measured from 3D ultrasound images
    Choi, Gary P. T.
    Chen, Yimin
    Lui, Lok Ming
    Chiu, Bernard
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (12) : 2183 - 2195