Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout

被引:109
|
作者
Huppertz, Alexander [1 ,2 ]
Hermann, Kay-Geert A. [1 ]
Diekhoff, Torsten [1 ]
Wagner, Moritz [1 ]
Hamm, Bernd [1 ,2 ]
Schmidt, Wolfgang A. [3 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
[2] Imaging Sci Inst Charite, D-10115 Berlin, Germany
[3] Immanuel Krankenhaus Berlin Buch, Med Ctr Rheumatol, D-13125 Berlin, Germany
关键词
Gout; Crystal deposition arthropathy; Dual-energy computed tomography; Ultrasonography; Polarisation microscopy; URIC-ACID; DIAGNOSIS; ULTRASONOGRAPHY; DISEASE; ARTHRITIS; INSIGHTS; JOINT; HYPERURICEMIA; INVOLVEMENT; MANAGEMENT;
D O I
10.1007/s00296-014-2979-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective of the study is to compare the diagnostic accuracy for detecting monosodium urate crystal deposits between dual-energy CT (DECT) and ultrasound (US). Sixty consecutive patients (49 men, mean age 62 years) with clinically suspected gout were included in this case-control study. DECT and US of feet, knees, hands and elbows were performed in all patients. Polarisation microscopy of synovial fluid or a score incorporating serum uric acid level, first MTP joint involvement, gender, previous patient-reported arthritis attack, cardiovascular diseases, joint redness and onset within 1 day was used as standard of reference. Standard of reference classified 39 patients as gout positive. Sixteen patients had gout and a concomitant rheumatic disease. Sensitivities for diagnosis of gout disease were 84.6 % (33/39) for DECT and 100 % (39/39) for US. Specificities were 85.7 % (18/21) for DECT and 76.2 % (16/21) for US. Positive and negative predictive values were 91.7 % (33/36) and 75.0 % (18/24) for DECT, 88.6 % (39/44) and 100 % (16/16) for US, respectively. Urate crystals were detected most frequently in MTP1 joints (DECT 20/78, US 58/78), any other toe joints (DECT 25/78, US 62/78) and knees (DECT 41/78, US 31/78). The volumetry of DECT computed a mean urate crystal deposit load of 2.1 cm(3) (SD 9.6 cm(3)). A mean effective dose of a parts per thousand currency sign0.5 mSv was estimated. DECT is more specific for the diagnosis of gout than US. However, it fails to detect small urate crystal deposits. It might be particularly useful for patients with ambivalent findings, concomitant rheumatic diseases and with non-conclusive joint aspiration.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 50 条
  • [1] Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout
    Alexander Huppertz
    Kay-Geert A. Hermann
    Torsten Diekhoff
    Moritz Wagner
    Bernd Hamm
    Wolfgang A. Schmidt
    Rheumatology International, 2014, 34 : 763 - 771
  • [2] Systematic Staging For Uric Acid Deposits With Dual-Energy Computed Tomography and Ultrasound In Suspected Gout.
    Schmidt, Wolfgang A.
    Huppertz, Alexander
    ARTHRITIS AND RHEUMATISM, 2013, 65 : S88 - S88
  • [3] Presence of monosodium urate crystal deposition by dual-energy CT in patients with gout treated with allopurinol
    Dalbeth, Nicola
    Nicolaou, Savvas
    Baumgartner, Scott
    Hu, Jia
    Fung, Maple
    Choi, Hyon K.
    ANNALS OF THE RHEUMATIC DISEASES, 2018, 77 (03) : 364 - 370
  • [4] Identification of monosodium urate crystal deposits in patients with asymptomatic hyperuricemia using dual-energy CT
    Wang, Penny
    Smith, Stacy E.
    Garg, Rajesh
    Lu, Fengxin
    Wohlfahrt, Alyssa
    Campos, Anarosa
    Vanni, Kathleen
    Yu, Zhi
    Solomon, Daniel H.
    Kim, Seoyoung C.
    RMD OPEN, 2018, 4 (01):
  • [5] Dual-Energy Computed Tomography Detection of Cardiovascular Monosodium Urate Deposits in Patients With Gout
    Klauser, Andrea Sabine
    Halpern, Ethan J.
    Strobl, Sylvia
    Gruber, Johann
    Feuchtner, Gudrun
    Bellmann-Weiler, Rosa
    Weiss, Guenter
    Stofferin, Hannes
    Jaschke, Werner
    JAMA CARDIOLOGY, 2019, 4 (10) : 1019 - 1028
  • [6] Patterns of Monosodium Urate Deposition on Dual-Energy CT in Gout Patients on Urate-Lowering Therapy
    Yokose, Chio
    Zhang, Yuqing
    Dalbeth, Nicola
    Wei, Jie
    Nicolaou, Savvas
    Baumgartner, Scott
    Hu, Jia
    Fung, Maple
    Choi, Hyon K.
    ARTHRITIS & RHEUMATOLOGY, 2018, 70
  • [7] Dual-Energy CT of Urate Deposits in Costal Cartilage and Intervertebral Disks of Patients With Tophaceous Gout and Age-Matched Controls
    Carr, Alexander
    Doyle, Anthony J.
    Dalbeth, Nicola
    Aati, Opetaia
    McQueen, Fiona M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (05) : 1063 - 1067
  • [8] Identification of Urate Deposits in Patients with Asymptomatic Hyperuricemia Using a Dual-Energy CT Scan
    Wang, Penny
    Smith, Stacy
    Garg, Rajesh
    Lu, Fengxin
    Wohlfahrt, Alyssa
    Campos, Anarosa
    Vanni, Kathleen
    Yu, Zhi
    Solomon, Daniel H.
    Kim, Seoyoung C.
    ARTHRITIS & RHEUMATOLOGY, 2017, 69
  • [9] Vascular Monosodium Urate Crystal Deposition in Gout: A Dual-energy CT and Microscopy Study of Cadaveric Donors
    Dalbeth, Nicola
    Alhilali, Mariam
    Riordan, Peter
    Narang, Ravi
    Chhana, Ashika
    McGlashan, Sue
    Doyle, Anthony
    Andres, Mariano
    ARTHRITIS & RHEUMATOLOGY, 2021, 73 : 3288 - 3289
  • [10] Comparision of Urate Burden in Well and Poorly Controlled Gout Patients: A Dual-Energy CT Study
    Chung, Min Kyung
    Hyun, Hyeran
    Hwang, Ji Young
    Lee, Jisoo
    ARTHRITIS & RHEUMATOLOGY, 2018, 70