The CMS level-1 τ lepton and Vector Boson Fusion triggers for the LHC Run II

被引:0
|
作者
Perez, C. Martin [1 ]
机构
[1] Ecole Polytech, IN2P3, CNRS, Lab Leprince Ringuet, Palaiseau, France
基金
英国科学技术设施理事会;
关键词
Trigger; Calorimetry;
D O I
10.1016/j.nima.2018.11.008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CMS experiment implements a sophisticated two-level triggering system composed of a hardware Level-1 and a software High Level Trigger. A new Level-1 trigger architecture with improved performance is now being used to maintain high physics efficiency for the more challenging luminosity conditions experienced during Run II. In this paper, the upgrades to the calorimeter trigger are shown along with performance measured on 2017 collision data. The algorithms for the selection of final states with hadronically decaying r leptons are described. The implementation of the first dedicated Vector Boson Fusion trigger algorithm is presented as well, along with its performance on Higgs physics signals.
引用
收藏
页码:370 / 371
页数:2
相关论文
共 50 条
  • [1] The CMS Level-1 trigger for LHC Run II
    Tapper, A.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [2] The CMS Level-1 Calorimeter Trigger for the LHC Run II
    Zabi, A.
    Beaudette, F.
    Cadamuro, L.
    Davignon, O.
    Romanteau, T.
    Strebler, T.
    Cepeda, M.
    Sauvan, J. B.
    Wardle, N.
    Aggleton, R.
    Ball, F.
    Brooke, J.
    Newbold, D.
    Paramesvaran, S.
    Smith, D.
    Taylor, J.
    Foudas, C.
    Baber, M.
    Bundock, A.
    Breeze, S.
    Citron, M.
    Elwood, A.
    Hall, G.
    Iles, G.
    Laner, C.
    Penning, B.
    Rose, A.
    Shtipliyski, A.
    Tapper, A.
    Ojalvo, I.
    Durkin, T.
    Harder, K.
    Harper, S.
    Shepherd-Themistocleous, C.
    Thea, A.
    Williams, T.
    Dasu, S.
    Dodd, L.
    Forbes, R.
    Gorski, T.
    Klabbers, P.
    Levine, A.
    Ruggles, T.
    Smith, N.
    Smith, W.
    Svetek, A.
    Tikalsky, J.
    Vicente, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [3] The CMS Level-1 trigger system for LHC Run II
    Cadamuro, L.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [4] The CMS Level-1 Tau identification algorithm for the LHC Run II
    Mastrolorenzo, L.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 273 : 2518 - 2520
  • [5] The CMS Level-1 electron and photon trigger: for Run II of LHC
    Dev, N.
    Jessop, C.
    Meng, F.
    Marinelli, N.
    Taroni, S.
    Beaudette, F.
    Cadamuro, L.
    Davignon, O.
    Romanteau, T.
    Strebler, T.
    Zabi, A.
    Sauvan, J. B.
    Marrouche, J.
    Wardle, N.
    Aggleton, R.
    Ball, F.
    Brooke, J.
    Newbold, D.
    Paramesvaran, S.
    Smith, D.
    Taylor, J.
    Baber, M.
    Bundock, A.
    Citron, M.
    Elwood, A.
    Hall, G.
    Iles, G.
    Laner, C.
    Penning, B.
    Rose, A.
    Shtipliyski, A.
    Tapper, A.
    Durkin, T.
    Harder, K.
    Harper, S.
    Shepherd-Themistocleous, C.
    Thea, A.
    Williams, T.
    Neu, C.
    Sinthuprasith, T.
    Xia, F.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [6] Level-1 Muon Triggers for the CMS Experiment at the HL-LHC
    Folgueras, Santiago
    EUROPEAN PHYSICAL SOCIETY CONFERENCE ON HIGH ENERGY PHYSICS, EPS-HEP2019, 2020,
  • [7] The level-1 global trigger for the CMS experiment at LHC
    Jeitler, M.
    Taurok, A.
    Bergauer, H.
    Deldicque, C.
    Eroe, J.
    Ghete, M.
    Glaser, P.
    Kastner, K.
    Mikulec, I.
    Noebauer, T.
    Neuherz, B.
    Padrta, M.
    Rohringer, H.
    Schreiner, T.
    Strauss, J.
    Wulz, C. -E.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [8] Moving NN triggers to level-1 at LHC rates
    Prévotet, JC
    Denby, B
    Garda, P
    Granado, B
    Kiesling, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 502 (2-3): : 511 - 512
  • [9] CMS Level-1 trigger Data Scouting firmware prototyping for LHC Run-3 and CMS Phase-2
    Ardino, Rocco
    Deldicque, Christian
    Dobson, Marc
    Gigi, Dominique
    Giorgetti, Sabrina
    James, Thomas Owen
    Miotto, Giovanna Lazzari
    Meschi, Emilio
    Migliorini, Matteo
    Petrucciani, Giovanni
    Rabady, Dinyar
    Racz, Attila
    Sakulin, Hannes
    Zejdl, Petr
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [10] Run 2 upgrades to the CMS Level-1 calorimeter trigger
    Kreis, B.
    Berryhill, J.
    Cavanaugh, R.
    Mishra, K.
    Rivera, R.
    Uplegger, L.
    Apanasevich, L.
    Zhang, J.
    Marrouche, J.
    Wardle, N.
    Aggleton, R.
    Ball, F.
    Brooke, J.
    Newbold, D.
    Paramesvaran, S.
    Smith, D.
    Baber, M.
    Bundock, A.
    Citron, M.
    Elwood, A.
    Hall, G.
    Iles, G.
    Laner, C.
    Penning, B.
    Rose, A.
    Tapper, A.
    Foudas, C.
    Beaudette, F.
    Cadamuro, L.
    Mastrolorenzo, L.
    Romanteau, T.
    Sauvan, J. B.
    Strebler, T.
    Zabi, A.
    Barbieri, R.
    Cali, I. A.
    Innocenti, G. M.
    Lee, Y. -J.
    Roland, C.
    Wyslouch, B.
    Guilbaud, M.
    Li, W.
    Northup, M.
    Tran, B.
    Durkin, T.
    Harder, K.
    Harper, S.
    Shepherd-Themistocleous, C.
    Thea, A.
    Williams, T.
    JOURNAL OF INSTRUMENTATION, 2016, 11