SpO2, heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery - a single-centre study

被引:1
|
作者
Czeszynska, Maria Beata [1 ]
Sontowska, Agnieszka [1 ]
机构
[1] Pomeranian Med Univ, Dept Neonatol, Szczecin, Poland
关键词
neonates; pneumothorax; non-invasive ventilation; POSITIVE AIRWAY PRESSURE; RESPIRATORY-DISTRESS-SYNDROME; PRETERM INFANTS; OXYGEN-SATURATION; NASAL CANNULAE; CPAP; BIRTH; NEWBORNS; SUPPORT; HYPOTENSION;
D O I
10.5114/ait.2020.100574
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: SpO(2), heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units. Objective: to determine the relationship between the aforementioned parameters and the status of newborns depending on the outcome of the Infant Flow (I-F) therapy, and the development of complications in the form of pneumothorax. Methods: A retrospective single-centre study covering the years 2009-2014. A total of 182 neonates, with mean gestational age 34.1 weeks and mean body weight 2226 g, were analysed. The minimum and maximum values of the evaluated parameters were analysed statistically according to the therapy outcome noted as success or failure. Results: A successful outcome of I-F therapy (71.4%) was characterised by higher SpO(2) (93.3 +/- 7.28 vs. 85.9 +/- 14.77 at P < 0.001; 99.95 +/- 0.31 vs. 98.6 +/- 3.30 at P < 0.0001), lower heart rate (122.5 +/- 12.37 vs. 135.9 +/- 14.97 at P < 0.0001), and higher max systolic blood pressure (79.05 +/- 12.49 vs. 69.78 +/- 13.73 mm Hg at P < 0.0001), max diastolic blood pressure (57.03 +/- 9.31 vs. 50.41 +/- 13.82 mm Hg; P < 0.0003), and max as well as min mean arterial blood pressure (46.8 +/- 10.13 vs. 41.39 +/- 15.46 mm Hg; P < 0.001) (27.88 +/- 5.71 vs. 26.14 +/- 7.35 mm Hg; P < 0.02). Conclusions: In newborns suffering from respiratory failure and treated with I-F, higher SpO2 values, lower heart rate, and higher arterial blood pressure coincide with success of the I-F therapy.
引用
收藏
页码:304 / 311
页数:8
相关论文
共 24 条
  • [1] Non-Invasive Study: Monitoring the Heart Rate and SpO2 of the New Born using InfaWrap Device
    Rahim, Mohd Hanafi Abdul
    Adib, Mohd Azrul Hisham Mohd
    Baharom, Mohamad Zairi
    Sahat, Idris Mat
    Hasni, Nur Hazreen Mohd
    2020 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES 2020): LEADING MODERN HEALTHCARE TECHNOLOGY ENHANCING WELLNESS, 2021, : 212 - 217
  • [2] Non-invasive arterial blood pressure measurement and SpO2 estimation using PPG signal: a deep learning framework
    Yan Chu
    Kaichen Tang
    Yu-Chun Hsu
    Tongtong Huang
    Dulin Wang
    Wentao Li
    Sean I. Savitz
    Xiaoqian Jiang
    Shayan Shams
    BMC Medical Informatics and Decision Making, 23
  • [3] Non-invasive arterial blood pressure measurement and SpO2 estimation using PPG signal: a deep learning framework
    Chu, Yan
    Tang, Kaichen
    Hsu, Yu-Chun
    Huang, Tongtong
    Wang, Dulin
    Li, Wentao
    Savitz, Sean I. I.
    Jiang, Xiaoqian
    Shams, Shayan
    BMC MEDICAL INFORMATICS AND DECISION MAKING, 2023, 23 (01)
  • [4] STROKE VOLUME ASSESSMENT BY INVASIVE ARTERIAL BLOOD PRESSURE TRACING, SPO2 AND BIOREACTANCE: A COMPARATIVE STUDY
    Wylleman, Jasper
    Maes, Tina
    Cool, Roxane
    Vervoort, Michel
    Poelaert, Jan
    ANESTHESIA AND ANALGESIA, 2018, 126 (04): : 656 - 657
  • [5] Impact of non-invasive ventilation on microbial colonisation patterns in preterm infants: a single-centre study
    Luo, Feixiang
    Shi, Wei
    Fan, Xiaoyan
    Zhou, Mingming
    Shen, Fei
    Zhu, Haihong
    Zhu, Jihua
    Chen, Zheng
    BMJ PAEDIATRICS OPEN, 2024, 8 (01)
  • [6] Non-invasive Ventilation in the Third Wave of the COVID-19 Pandemic: a Single-centre Retrospective Study
    Gritsan, Alexey
    Avdeev, Nikolay
    Demko, Irina
    ANESTHESIA AND ANALGESIA, 2024, 139 (06): : 135 - 136
  • [7] Resource use, characteristics and outcomes of prolonged non-invasive ventilation: a single-centre observational study in China
    Duan, Jun
    Bai, Linfu
    Zhou, Lintong
    Han, Xiaoli
    Jiang, Lei
    Huang, Shicong
    BMJ OPEN, 2018, 8 (12):
  • [8] Consistency of the Non-Invasive Monitoring Preemie Car Seat (PreeCASE) Device in Assessing Heart Rate, SpO2 Level, and Body Temperature of the Infants
    Zin, Muhammad Afiq Firdaus Md
    Adib, Mohd Azrul Hisham Mohd
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2024, 21 (03) : 11569 - 11580
  • [9] Initiation of non-invasive ventilation in amyotrophic lateral sclerosis and clinical practice guidelines: Single-centre, retrospective, descriptive study in a national reference centre
    Georges, Marjolaine
    Golmard, Jean-Louis
    Llontop, Claudia
    Shoukri, Amr
    Salachas, Francois
    Similowski, Thomas
    Morelot-Panzini, Capucine
    Gonzalez-Bermejo, Jesus
    AMYOTROPHIC LATERAL SCLEROSIS AND FRONTOTEMPORAL DEGENERATION, 2017, 18 (1-2) : 46 - 52
  • [10] The application and reliability of continuous non-invasive arterial blood pressure monitoring in elderly patients during surgery
    Zhou, Shuzhi
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 668 - 668