Performance of Legiolert Test vs. ISO 11731 to Confirm Legionella pneumophila Contamination in Potable Water Samples

被引:20
|
作者
Scaturro, Maria [1 ]
Buffoni, Matteo [1 ]
Girolamo, Antonietta [1 ]
Cristino, Sandra [2 ]
Girolamini, Luna [2 ]
Mazzotta, Marta [2 ]
Sabattini, Maria Antonietta Bucci [3 ]
Zaccaro, Cristina Maria [3 ]
Chetti, Leonarda [3 ]
Bella, Antonino [1 ]
Rota, Maria Cristina [1 ]
Ricci, Maria Luisa [1 ]
机构
[1] Natl Inst Hlth, Dept Infect Dis, Viale Regina Elena 299, I-00161 Rome, Italy
[2] Univ Bologna, Dept Biol Geol & Environm Sci, Via San Giacomo 12, I-40126 Bologna, Italy
[3] Hlth Protect Agcy Bologna, Reference Lab Environm Control, Via Trachini 17, I-40138 Bologna, Italy
[4] Hlth Protect Agcy, Reference Lab Environm Control, Viale Roma 7-E, I-28100 Rome, Italy
来源
PATHOGENS | 2020年 / 9卷 / 09期
关键词
Legionella; Legiolert; ISO; 11731; plate culture; potable water samples; LEGIONNAIRES-DISEASE; MONITORING LEGIONELLA; OUTBREAK; PCR; ACCURACY; DIAGNOSIS; CULTURE;
D O I
10.3390/pathogens9090690
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Detection and enumeration of Legionella in water samples is of great importance for risk assessment analysis. The plate culture method is the gold standard, but has received several well-known criticisms, which have induced researchers to develop alternative methods. The purpose of this study was to compare Legionella counts obtained by the analysis of potable water samples through the plate culture method and through the IDEXX liquid culture Legiolert method. Legionella plate culture, according to ISO 11731:1998, was performed using 1 L of water. Legiolert was performed using both the 10 mL and 100 mL Legiolert protocols. Overall, 123 potable water samples were analyzed. Thirty-seven (30%) of them, positive for L. pneumophila, serogroups 1 or 2-14 by plate culture, were used for comparison with the Legiolert results. The Legiolert 10 mL test detected 34 positive samples (27.6%) and the Legiolert 100 mL test detected 37 positive samples, 27.6% and 30% respectively, out of the total samples analyzed. No significant difference was found between either the Legiolert 10 mL and Legiolert 100 mL vs. the plate culture (p = 0.9 and p = 0.3, respectively) or between the Legiolert 10 mL and Legiolert 100 mL tests (p = 0.83). This study confirms the reliability of the IDEXX Legiolert test for Legionella pneumophila detection and enumeration, as already shown in similar studies. Like the plate culture method, the Legiolert assay is also suitable for obtaining isolates for typing purposes, relevant for epidemiological investigations.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 16 条
  • [1] Comparison of the Legiolert™/Quanti-Tray® MPN test for the enumeration of Legionella pneumophila from potable water samples with the German regulatory requirements methods ISO 11731-2 and ISO 11731
    Spies, Kirsten
    Pleischl, Stefan
    Lange, Bernd
    Langer, Bettina
    Huebner, Iris
    Jurzik, Lars
    Luden, Katrin
    Exner, Martin
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2018, 221 (07) : 1047 - 1053
  • [2] Concordance between IDEXX Legiolert® (liquid culture assay) and plate culture (ISO 11731:2017) for the detection and quantification of Legionella pneumophila in water samples
    Karia, K.
    Yui, S.
    Muzslay, M.
    Ali, S.
    JOURNAL OF HOSPITAL INFECTION, 2024, 150 : 163 - 168
  • [3] Evaluation of Legiolert for Quantification of Legionella pneumophila from Non-potable Water
    Melanie M. Rech
    Brian M. Swalla
    Jason K. Dobranic
    Current Microbiology, 2018, 75 : 1282 - 1289
  • [4] Evaluation of Legiolert for Quantification of Legionella pneumophila from Non-potable Water
    Rech, Melanie M.
    Swalla, Brian M.
    Dobranic, Jason K.
    CURRENT MICROBIOLOGY, 2018, 75 (10) : 1282 - 1289
  • [5] Evaluation of Legiolert for Quantification of Legionella pneumophila from Bath Water Samples
    Inoue, Hiroaki
    Baba, Masumi
    Tayama, Seina
    BIOCONTROL SCIENCE, 2020, 25 (03) : 179 - 182
  • [6] Comparison of two culture methods for the enumeration of Legionella pneumophila from potable water samples
    Boczek, Laura A.
    Tang, Min
    Formal, Casey
    Lytle, Darren
    Ryu, Hodon
    JOURNAL OF WATER AND HEALTH, 2021, 19 (03) : 468 - 477
  • [7] The use of BCYE medium for the detection of Legionella in environmental water samples: an appropriate update to ISO 11731:2017 standard?
    Ditommaso, Savina
    Giacomuzzi, Monica
    Memoli, Gabriele
    Garlasco, Jacopo
    Zotti, Carla M.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2022, 102 (02)
  • [8] Comparison of culture media for the detection of Legionella spp. in sanitary water samples: Adaptation to ISO 11731:2017
    Mayordomo, Marta Jimenez
    Vila, Mari Carmen Breso
    Cardona, Concepcion Gimeno
    Mochon, Maria Dolores Ocete
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2024, 42 (07): : 373 - 376
  • [9] Evaluation of a most probable number method for the enumeration of Legionella pneumophila from potable and related water samples
    Sartory, D. P.
    Spies, K.
    Lange, B.
    Schneider, S.
    Langer, B.
    LETTERS IN APPLIED MICROBIOLOGY, 2017, 64 (04) : 271 - 275
  • [10] Recovery of Legionella species from water samples using an internal method based on ISO 11731: suggestions for revision and implementation
    Ditommaso, Savina
    Gentile, Marino
    Giacomuzzi, Monica
    Zotti, Carla Maria
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2011, 70 (02) : 200 - 206