Morphological and clinical feasibility of C3 pedicle screw instrumentation in patients with congenital C2-3 fusion

被引:4
|
作者
Xiu, Peng [1 ,2 ]
Wang, Qing [2 ]
Wang, Gaoju [2 ]
Wang, Song [2 ]
Dai, Guidong [3 ]
Lan, Yongshu [3 ]
机构
[1] Peking Univ, Hosp 3, Dept Orthoped, Beijing 100871, Peoples R China
[2] Luzhou Med Coll, Affiliated Hosp, Dept Spinal Surg, Luzhou 646000, Peoples R China
[3] Luzhou Med Coll, Affiliated Hosp, Dept Radiol, Luzhou 646000, Peoples R China
关键词
Congenital C2-3 fusion; Atlantoaxial dislocation; Pedicle screw; Three-dimensional CT; Occipitocervical fixation; HUMAN CERVICAL PEDICLES; KLIPPEL-FEIL PATIENT; ANATOMIC CONSIDERATION; VERTEBRAL ARTERY; PLACEMENT; FIXATION; PROJECTION; JUNCTION; SPINE; AXIS;
D O I
10.1007/s00586-014-3397-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Congenital C2-3 fusion (C2-3CF) is often involved in patients with atlantoaxial dislocation, and posterior occipitocervical fixation surgery is usually required. Hypoplasia of C2 pedicle is common in such patients, making C2 pedicle screws (PS) instrumentation inapplicable. Because of congenital fusion, C3PS instrumentation would be an ideal alternative for it will not sacrifice an additional motion segment; however, the morphological and clinical feasibility has not been previously reported. We included 42 C2-3CF patients to this study and evaluated pedicle trajectories of C2 and C3 using a three-dimensional CT. Clinical applications of C3PS instrumentation were evaluated and followed. Among the 42 patients, 23 (54.8 %) and 8 (19.0 %) had C2 and C3 pedicle trajectory diameters < 4.0 mm, respectively. The bisection line of the fused C2-3 lamina was used to represent the superior border of C3 articular mass; the entry point of C3 pedicle was located at 3 mm inferior to the assumed superior border and 3.2 mm medial to the lateral border. Bilateral C3PS instrumentations were successfully adopted in 22 patients. No spinal cord or vertebral artery injury occurred; postoperative CT showed a trajectory breach rate of 17.4 % for C3PS. After mean of 3.6-year follow-up, no implant failure was documented. C3PS instrumentation is morphologically and clinically feasible for a large proportion of patients with C2-3CF and can serve as another reliable alternative for C2PS instrumentation. Preoperative evaluation of pedicle trajectory of C2-3CF with three-dimensional CT is highly valuable in the choice of proper fixation methods.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 50 条
  • [1] Morphological and clinical feasibility of C3 pedicle screw instrumentation in patients with congenital C2–3 fusion
    Peng Xiu
    Qing Wang
    Gaoju Wang
    Song Wang
    Guidong Dai
    Yongshu Lan
    European Spine Journal, 2014, 23 : 1730 - 1736
  • [2] Cable-Strengthened C2 Pedicle Screw Fixation in the Treatment of Congenital C2-3 Fusion, Atlas Occipitalization, and Atlantoaxial Dislocation
    Wang, Shenglin
    Wang, Chao
    Leng, Huijie
    Zhao, Weidong
    Yan, Ming
    Zhou, Haitao
    NEUROSURGERY, 2012, 71 (05) : 976 - 984
  • [3] Cable-Strengthened C2 Pedicle Screw Fixation in the Treatment of Congenital C2-3 Fusion, Atlas Occipitalization, and Atlantoaxial Dislocation COMMENT
    Than, Khoi D.
    La Marca, Frank
    NEUROSURGERY, 2012, 71 (05) : 984 - 984
  • [4] Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2-3 fusion patients?
    Wang, Shenglin
    Wang, Chao
    Passias, Peter G.
    Yan, Ming
    Zhou, Haitao
    EUROPEAN SPINE JOURNAL, 2010, 19 (08) : 1306 - 1311
  • [5] FAMILIAL C2-3 FUSION
    GUNDERSON, CH
    LUBS, HA
    NEUROLOGY, 1964, 14 (03) : 272 - &
  • [6] Pedicle Screw Combined With Lateral Mass Screw Fixation in the Treatment of Basilar Invagination and Congenital C2-C3 Fusion
    Wang, Shenglin
    Wang, Chao
    Leng, Huijie
    Zhao, Weidong
    Yan, Ming
    Zhou, Haitao
    CLINICAL SPINE SURGERY, 2016, 29 (10): : 448 - 453
  • [7] C2 translaminar screw as the optimal choice for atlantoaxial dislocation with C2–C3 congenital fusion
    Fengjin Zhou
    Bin Ni
    Songkai Li
    Jian Yang
    Xiang Guo
    Zhuangchen Zhu
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1505 - 1509
  • [8] In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation
    Reddy, Chandan
    Ingalhalikar, Aditya V.
    Channon, Scott
    Lim, Tae-Hong
    Torner, James
    Hitchon, Patrick W.
    JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (04) : 414 - 418
  • [9] A screw algorithm for congenital C2-3 fusion with high-riding vertebral arteries: feasibilities and clinical outcomes of five different fixation techniques
    Jian, Qiang
    Hou, Zhe
    Zhao, Xingang
    Wang, Yinqian
    Liang, Cong
    Fan, Tao
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [10] The predictive ability of occipital to C3 angle for dysphagia after occipitocervical fusion in patients with combined C2-3 Klippel-Feil syndrome
    Zou, Qiang
    Wang, Linnan
    Yang, Xi
    Song, Yueming
    Liu, Limin
    Wang, Lei
    Zhou, Zhongjie
    Hu, Bowen
    Chen, Taiyong
    Liu, Hao
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)