On-line beam performance monitoring to improve laser reliability and performance

被引:5
|
作者
Green, LI [1 ]
机构
[1] Spiricon Inc, Logan, UT 84341 USA
来源
关键词
measurement; monitoring; laser performance; profiling; divergence; beam performance; M-2;
D O I
10.1117/12.469493
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Industrial Lasers must have high reliability and repeatability so that the process for which they are to be used is profitable and successful. Current methodology for measuring the performance of high power industrial lasers is incapable of real time data. We describe two new instruments; a new on-line, in-line laser beam performance monitoring system that not only calculates M-2 and divergence angle, but also provides real time beam profiling, and an at-line beam profiling system that can calculate beam widths and many other critical parameters in real time. The information obtained from these measurements allows the operator to monitor beam performance in real time, speed tuning and adjustment. more accurately predict maintenance intervals and aid in troubleshooting malfunctions. Actual examples of different lasers will show the value of these systems.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 50 条
  • [1] PUSHING PERFORMANCE WITH ON-LINE MONITORING.
    Moore, Taylor
    [J]. EPRI Journal, 1988, 13 (06): : 4 - 13
  • [2] On-line performance monitoring using OMIS
    Bubak, M
    Funika, W
    Iskra, K
    Maruszewski, R
    [J]. RECENT ADVANCES IN PARALLEL VIRTUAL MACHINE AND MESSAGE PASSING INTERFACE, 1998, 1497 : 3 - 10
  • [3] On-line monitoring of penetration depth in laser beam welding
    Beersiek, J
    Poprawe, R
    Schulz, W
    Gu, HP
    Mueller, RE
    Duley, WW
    [J]. LASER MATERIALS PROCESSING CONFERENCE, PTS 1 & 2: ICALEO '97, 1997, : C30 - C39
  • [4] On-line tracer system to improve enzyme performance
    Iogen Corp., Ottawa, Ont., Canada
    不详
    [J]. Pulp Pap Can, 2 (36-40):
  • [5] On-line tracer system to improve enzyme performance
    Tolan, JS
    Spence, M
    [J]. 82ND ANNUAL MEETING, TECHNICAL SECTION, CANADIAN PULP AND PAPER ASSOCIATION - CREATING AN ENVIRONMENT FOR THE FUTURE, PREPRINTS A, 1996, : A21 - A28
  • [6] On-line tracer system to improve enzyme performance
    Tolan, JS
    Spence, M
    [J]. PULP & PAPER-CANADA, 1997, 98 (02) : 36 - 40
  • [7] Industrial implementation of on-line performance monitoring tools
    Hägglund, T
    [J]. CONTROL ENGINEERING PRACTICE, 2005, 13 (11) : 1383 - 1390
  • [8] ON-LINE MONITORING OF THE BCDMS SPECTROMETER PERFORMANCE.
    Deiters, K.
    Fournier, J.P.
    Karzhavin, V.Y.
    Kazarinov, M.Y.
    Michau, J.C.
    Renardy, J.F.
    Staude, A.
    Strachota, J.
    Tiechert, K.M.
    [J]. Nuclear instruments and methods in physics research, 1988, A270 (2-3): : 477 - 480
  • [9] Boost turbine performance with on-line condenser monitoring
    不详
    [J]. POWER, 2002, 146 (01) : 18 - +
  • [10] On-line monitoring of keyhole instabilities during laser beam welding
    Beersiek, J
    [J]. ICALEO (R)'99: PROCEEDING OF THE LASER MATERIALS PROCESSING CONFERENCE, VOL 87, PTS 1 AND 2, 2000, 87 : D49 - D58