A NOVEL NON-INVASIVE METHOD FOR ESTIMATING ARTERIAL COMPLIANCE WITH TREADMILL EXERCISE TEST

被引:0
|
作者
Sato, T. [1 ]
Yamada, Y. [1 ]
Kohama, Y. [1 ]
Hirata, T. [1 ]
Kamishima, K. [1 ]
Ikeda, H. [1 ]
Okada, H. [1 ]
Sugiura, R. [1 ]
Oka, T. [1 ]
机构
[1] Seirei Hamamatsu Gen Hosp, Hamamatsu, Shizuoka, Japan
关键词
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
引用
收藏
页码:S94 / S94
页数:1
相关论文
共 50 条
  • [1] A novel magnetic plethysmograph for non-invasive evaluation of arterial compliance
    Chandrasekhar, Anand
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1169 - 1172
  • [2] Non-invasive estimation of arterial compliance
    Joseph, Jayaraj
    Venkataraman, Jayashankar
    Kumar, Jagadeesh, V
    Suresh, S.
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 480 - 484
  • [3] NON-INVASIVE DETERMINATION OF ARTERIAL COMPLIANCE
    CHAI, SD
    NING, XH
    CHOU, CN
    CHOU, ZM
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (04) : 424 - 429
  • [4] Jacketed telemetry in rats: a novel non-invasive method for cardiorespiratory phenotyping during treadmill exercise
    Tanguy, Stephane
    Cambier, Agathe
    Fontana-Pires, Leandro
    Flenet, Timothe
    Eynard, Charles
    Fontecave-Jalon, Julie
    Gumery, Pierre-Yves
    Boucher, Francois
    LABORATORY ANIMALS, 2024,
  • [5] A non-invasive pulse pressure method for the estimation of total arterial compliance
    Segers, P
    Stergiopulos, N
    Verdonck, P
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 171 - 174
  • [6] The pulse pressure method for non-invasive evaluation of total arterial compliance
    Carlier, S
    Segers, P
    De Backer, T
    Stergiopoulos, N
    Thomas, J
    JOURNAL OF HYPERTENSION, 2000, 18 : S197 - S197
  • [7] A Novel Non-Invasive Method of Estimating Pulmonary Vascular Resistance in Patients With Pulmonary Arterial Hypertension
    Haddad, Francois
    Zamanian, Roham
    Beraud, Anne-Sophie
    Schnittger, Ingela
    Feinstein, Jeffrey
    Peterson, Tyler
    Yang, Phil
    Doyle, Ramona
    Rosenthal, David
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (05) : 523 - 529
  • [8] Method of non-invasive assessment of myocardial compliance
    Hu, W. C.
    Liu, C. P.
    Hus, T. J.
    Shyu, L. Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3419 - +
  • [9] A Non-invasive Radial Arterial Compliance Measuring Method using Bio-Impedance
    Tang, Xiaochen
    Jankovic, Matija
    Jafari, Roozbeh
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 2330 - 2334
  • [10] Non-invasive measurement of arterial pressure-dependent compliance
    Liu, Changchun
    Xin, Sun
    Liu, Chengyu
    Gu, Jason J.
    Yu, Mengsun
    2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 590 - 593