Impairment of Iodine-123-Metaiodobenzylguanidine (123I-MIBG) Uptake in Patients with Pulmonary Artery Hypertension

被引:4
|
作者
Higo, Kenjuro [1 ]
Kubota, Kayoko [1 ]
Miyanaga, Sunao [1 ]
Miyata, Masaaki [1 ]
Nakajo, Masatoyo [2 ]
Jinguji, Megumi [2 ]
Ohishi, Mitsuru [1 ]
机构
[1] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Cardiovasc Med & Hypertens, 8-35-1 Sakuragaoka, Kagoshima 8908520, Japan
[2] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Radiol, Kagoshima, Japan
关键词
Pulmonary hypertension; 123I-MIBG scintigraphy; Endothelial dysfunction; CONNECTIVE-TISSUE DISEASE; GLYCATION END-PRODUCTS; REDUCED LUNG UPTAKE; ENDOTHELIAL DYSFUNCTION; SCINTIGRAPHIC ASSESSMENT; METABOLIC FUNCTION; RECENT PROGRESS; HEART-FAILURE; METAIODOBENZYLGUANIDINE; MANAGEMENT;
D O I
10.1536/ihj.16-629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
According to recent studies, lung uptake of iodine-123-metaiodobenzylguanidine (I-123-MIBG) is impaired in many lung diseases and low lung uptake of I-123-MIBG suggests endothelial dysfunction of the pulmonary artery. I-123-MIBG scintigraphy in patients with pulmonary hypertension (PH) has not yet been clinically evaluated. We hypothesized that the lung uptake of I-123-MIBG is reduced in patients with PH and differs among PH subtypes. The purpose of the present study was to analyze the lung uptake of 123I-MIBG in patients with PH and compare it with the data obtained by echocardiography or right heart catheterization. I-123-MIBG scintigraphy was performed in 286 consecutive patients from 2003 to 2014. We enrolled 21 patients with PH and 8 control patients. The 21 patients with PH were categorized into those with pulmonary artery hypertension (PAH, n = 12) and those with chronic thromboembolic pulmonary hypertension (CTEPH, n = 9). The mean pulmonary artery pressure was not significantly different between patients with CTEPH and PAH (37.7 +/- 6.8 versus 32.3 +/- 5.3 mmHg respectively; P = 0.054). There were no significant differences in any other hemodynamic parameters between the two groups. The lung uptake of I-123-MIBG in PAH patients (early image: 1.54 +/- 0.18, delayed image: 1.41 +/- 0.16) was significantly lower than that of CTEPH patients (early image: 2.17 +/- 0.25, P < 0.0001; delayed image: 1.99 +/- 0.20, P = 0.0001, adjusted for age and World Health Organization classification) and controls (early image: 2.32 +/- 0.27, P = 0.0007; delayed image: 1.92 +/- 0.19, P = 0.0007). In conclusion, we found for the first time that the lung uptake of 123I-MIBG in patients with PAH is lower than that in patients with CTEPH and controls.
引用
收藏
页码:112 / 119
页数:8
相关论文
共 50 条
  • [1] Myocardial iodine-123-metaiodobenzylguanidine (123I-MIBG) imaging in Brugada syndrome
    Furuhashi, M
    Uno, K
    Tsuchihashi, K
    [J]. CIRCULATION, 2002, 106 (13) : E59 - E59
  • [2] First steps in imaging the right ventricle with iodine-123-metaiodobenzylguanidine (123I-MIBG) and cadmium-zinc-telluride technology
    Anisiia Doytchinova
    Myron Gerson
    [J]. Journal of Nuclear Cardiology, 2021, 28 : 557 - 559
  • [3] First steps in imaging the right ventricle with iodine-123-metaiodobenzylguanidine (123I-MIBG) and cadmium-zinc-telluride technology
    Doytchinova, Anisiia
    Gerson, Myron
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (02) : 557 - 559
  • [4] Evaluation of 123I-MIBG uptake into the adrenal medulla in 123I-MIBG scintigraphy
    Abe, S.
    Kato, K.
    Odagawa, T.
    Fujita, N.
    Fujita, Y.
    Niwa, A.
    Naganawa, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S380 - S381
  • [5] Time to Resolution of Iodine 123 Metaiodobenzylguanidine (123I-MIBG) Avidity in Neuroblastoma Following Radiation Therapy
    Sodji, Q.
    Sandhu, N.
    Majzner, R.
    Nadel, H.
    Callejas, M.
    Donaldson, S. S.
    Hiniker, S. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E238 - E239
  • [6] Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washout
    Verberne, Hein J.
    Somsen, G. Aernout
    Povinec, Pavol
    van Eck-Smit, Berthe L. F.
    Jacobson, Arnold F.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (08) : 1322 - 1328
  • [7] Iodine-123-metaiodobenzylguanidine imaging and coronary artery disease in patients with NIDDM
    Kamado, K
    Gorogawa, S
    Kuroda, A
    Morozumi, T
    Nanto, S
    Nagata, M
    Shimonagata, T
    Fukuchi, M
    [J]. DIABETOLOGIA, 1997, 40 : 2268 - 2268
  • [8] Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washout
    Hein J. Verberne
    G. Aernout Somsen
    Pavol Povinec
    Berthe L. F. van Eck-Smit
    Arnold F. Jacobson
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1322 - 1328
  • [9] 123I-MIBG Thyroid Uptake
    Giubbini, Raffaele
    Campini, Riccardo
    Fracassi, Federica
    Milan, Elisa
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [10] Evaluation of sympathetic re-innervation in heterotopic cardiac transplants by iodine-123-metaiodobenzylguanidine (I-123-MIBG) imaging
    Yap, Kenneth S. K.
    Gould, Paul
    Kalff, Victor
    Kaye, David M.
    Esmore, Don
    Kelly, Michael J.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (08): : 977 - 980