Diagnostic value of Flash dual-source CT coronary artery imaging combined with dual-energy myocardial perfusion imaging for coronary heart disease

被引:15
|
作者
Zhao, Rui-Ping [1 ]
Hao, Zhi-Ru [1 ]
Song, Zhi-Jun [2 ]
机构
[1] Cent Hosp Baotou, Dept Cardiol, Baotou 014040, Inner Mongolia, Peoples R China
[2] Cent Hosp Baotou, Dept Surg Oncol, Baotou 014040, Inner Mongolia, Peoples R China
关键词
coronary artery imaging; myocardial perfusion; dual-source CT; coronary heart disease; CARDIAC COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; CLINICAL CARDIOLOGY; INITIAL-EXPERIENCE; NUCLEAR-CARDIOLOGY; ANGIOGRAPHY; ISCHEMIA; STRESS; COMMITTEE; ACCURACY;
D O I
10.3892/etm.2014.1541
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The present study aimed to investigate the diagnostic value of Flash dual-source CT coronary angiography (DS-CTA) combined with dual-energy myocardial perfusion imaging (DS-CTP) for coronary heart disease (CHD), as a single-stage examination. A total of 60 patients with CHD underwent DS-CT examination, as well as coronary angiography (CAG), as the reference standard. The patients were divided into <50% and >= 50% stenosis groups based on their coronary angiograms. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the method for diagnosing stenosis of >= 50% were evaluated via DS-CTA combined with DS-CTP. Of the 60 patients, 59 showed satisfactory results that conformed to the diagnostic requirements. Using CAG as the reference standard, the sensitivity, specificity and positive and negative predictive values of the Flash DS-CT results in the >= 50% vascular stenosis group were 83.7, 92.7, 88.9 and 89.1%, respectively. The respective values for DS-CTA combined with DS-CTP for diagnosing CHD were 94.2, 91.1, 88.0 and 95.8%. Therefore, the results obtained indicate that DS-CTA combined with DS-CTP has a high diagnostic value for CHD. DS-CT is advantageous for diagnosing and prognosticating CHD.
引用
收藏
页码:865 / 868
页数:4
相关论文
共 50 条
  • [1] Diagnostic accuracy of coronary CT angiography combined with dual-energy myocardial perfusion imaging for detection of myocardial infarction
    Han, Ruijuan
    Sun, Kai
    Lu, Bin
    Zhao, Ruiping
    Li, Kuncheng
    Yang, Xinchun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (01) : 207 - 213
  • [2] Value of Dual-energy Lung Perfusion Imaging Using a Dual-source CT System for the Pulmonary Embolism
    Zhang, Jinshan
    Cai, Jing
    Liu, Shulan
    Zhang, Xianmei
    OPEN LIFE SCIENCES, 2018, 13 (01): : 107 - 111
  • [3] Dual-energy CT and coronary imaging
    Kay, Fernando Uliana
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (04) : 1090 - 1107
  • [4] Diagnostic value of quantitative parameters for myocardial perfusion assessment in patients with suspected coronary artery disease by single- and dual-energy computed tomography myocardial perfusion imaging
    Ruiz-Munoz, Aroa
    Valente, Filipa
    Dux-Santoy, Lydia
    Guala, Andrea
    Teixido-Tura, Gisela
    Galian-Gay, Laura
    Gutierrez, Laura
    Fernandez-Galera, Ruben
    Casas, Guillem
    Gonzalez-Alujas, Teresa
    Ferreira-Gonzalez, Ignacio
    Evangelista, Arturo
    Rodriguez-Palomares, Jose
    IJC HEART & VASCULATURE, 2021, 32
  • [5] Dual-energy CT might be a better way for optimising myocardial and coronary artery imaging
    Pan, Cunxue
    Azhati, Gulina
    Xing, Yan
    Liu, Wenya
    Li, Jingjing
    Ma, Haiting
    Xiao, Hu
    Wang, Haitao
    Dang, Jun
    Yang, Wen
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 215 : 62 - 64
  • [6] The comprehensive evaluation of Coronary artery anatomy and myocardial perfusion imaging using dual-source computed tomography of the heart: comparison with conventional coronary angiography
    Qin Ling
    Wang Yining
    Han Yechen
    Yang Ming
    Zeng Yong
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C124 - C124
  • [7] Analysis on clinical value of dual-source CT coronary angiography combined with SPECT in assessing correlation between myocardial perfusion abnormality and coronary artery stenosis
    Feng, Haixia
    Xun, Jing
    Gu, Long
    Wang, Yanhui
    Li, Yan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (05): : 4842 - 4850
  • [8] Pancreatic dual-source dual-energy CT: Is it time to discard unenhanced imaging?
    Mileto, Achille
    Mazziotti, Silvio
    Gaeta, Michele
    Bottari, Antonio
    Zimbaro, Fabrizio
    Giardina, Claudio
    Ascenti, Giorgio
    CLINICAL RADIOLOGY, 2012, 67 (04) : 334 - 339
  • [9] Quantitative imaging of chemical composition using dual-energy, dual-source CT
    Liu, Xin
    Primak, Andrew N.
    Yu, Lifeng
    McCollough, Cynthia H.
    Morin, Richard L.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [10] THE DIAGNOSTIC VALUE OF DUAL-SOURCE CT IN PATIENTS SUSPECTED OF CORONARY ARTERY DISEASE: A META-ANALYSIS
    Li Min
    Zhang Xiaona
    Ma Shaohui
    Zhang Ming
    HEART, 2010, 96 : A217 - A217