Adequacy Assessment of Power Systems Containing Wind Farm Subjected to Expansion

被引:0
|
作者
Bashi, Mazaher Haji [1 ]
Ebrahimi, Akaber [1 ]
机构
[1] Isfahan Univ Technol, Dept Elect & Comp Engn, Esfahan, Iran
关键词
wind farm expansion; adequacy assessment; large scale wind farms; installation capacity; ENERGY;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
progressive interest of exploitation of wind energy will lead to the installation of GW rated wind farms (WF) in near feature. Large wind farms integration to the power system motivates the studies about the effectiveness of wind power on the ability of power system to supply the demand. An algorithm is proposed determining that to what extent increasing the wind farm installed capacity could improve the adequacy indices of power system. The effect of wind farm expansion on the adequacy indices is studied via an analytical approach. The profiles of adequacy indices for a test system will be studied while the installed wind farm is undergoing expansion and the characteristics of the improvement for these indices are compared with an expansion program for conventional generation system. The results strongly suggest that pure wind generation expansion is not adequate and power system shall need to conventional generation units for preserving the power system adequacy indices.
引用
收藏
页码:548 / 553
页数:6
相关论文
共 50 条
  • [1] Adequacy assessment of generating systems containing wind power considering wind speed correlation
    Gao, Y.
    Billinton, R.
    [J]. IET RENEWABLE POWER GENERATION, 2009, 3 (02) : 217 - 226
  • [2] Adequacy Evaluation of Wind Farm Integration in Power Generation and Transmission Systems
    Zhang, Shuo
    Li, Gengyin
    Zhou, Ming
    [J]. 2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1572 - 1578
  • [3] Adequacy Assessment Considerations in Wind Integrated Power Systems
    Billinton, Roy
    Karki, Rajesh
    Gao, Yi
    Huang, Dange
    Hu, Po
    Wangdee, Wijarn
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (04) : 2297 - 2305
  • [4] A Reliability Assessment Model of a Wind Farm for Generation Adequacy Studies of Wind Integrated Power System
    Roy, Asish
    Sahoo, Subhendu Sekhar
    Chatterjee, Kalyan
    [J]. 2017 THIRD INTERNATIONAL CONFERENCE ON SCIENCE TECHNOLOGY ENGINEERING & MANAGEMENT (ICONSTEM), 2017, : 566 - 570
  • [5] Assessment of wind power capacity in power systems to meet the adequacy indexes
    [J]. Li, Jinghua (happyjinghua@163.com), 1600, Power System Technology Press (38):
  • [6] Four Dimension Wind Speed Model for Adequacy Assessment of Power Systems with Wind Farms
    Wang, Peng
    Han, Xiaoqing
    Qu, Ying
    Yang, Junhu
    [J]. 2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [7] Generation Adequacy Assessment for Power Systems with Wind Turbine and Energy Storage
    Zheng, Ruimin
    Zhong, Jin
    [J]. 2010 INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2010,
  • [8] Risk Assessment of Power Systems Integrated with Wind Farm and SMES
    Chen, Zhen
    Xiao, Xian Yong
    Li, Chang Song
    [J]. 2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 171 - 172
  • [9] Four-Dimensional Wind Speed Model for Adequacy Assessment of Power Systems With Wind Farms
    Han, Xiaoqing
    Qu, Ying
    Wang, Peng
    Yang, Junhu
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) : 2978 - 2985
  • [10] A meteorological information mining-based wind speed model for adequacy assessment of power systems with wind power
    Guo, Yifei
    Gao, Houlei
    Wu, Qiuwei
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 93 : 406 - 413