Creatinine sensor based on a molecularly imprinted polymer-modified hanging mercury drop electrode

被引:83
|
作者
Lakshmi, Dhana [1 ]
Prasad, Bhim Bali [1 ]
Sharma, Piyush Sindhu [1 ]
机构
[1] Banaras Hindu Univ, Dept Chem, Analyt Div, Varanasi 221005, Uttar Pradesh, India
关键词
creatinine sensor; molecularly imprinted polymer; differential pulse cathodic stripping voltammetry; blood serum;
D O I
10.1016/j.talanta.2006.02.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecularly imprinted polymers (MIP) have been elucidated to work as artificial receptors. In our present study, a MIP was applied as a molecular recognition element to a chemical sensor. We have constructed a creatinine sensor based on a MIP layer selective for creatinine and its differential pulse, cathodic stripping voltammetric detection (DPCSV) on a hanging mercury drop electrode (HMDE). The creatinine sensor was fabricated by the drop coating of dimethylformamide (DMF) solution of a creatinine-imprinted polymer onto the surface of HMDE. The modified-HMDE, preanodised in neutral medium at +0.4 V versus Ag/AgCl for 120s, exhibited a marked enhancement in DPCSV current in comparison to the less anodised (<=+0.3 V) HMDE. The creatinine was preconcentrated and instantaneously oxidised in MIP layer giving DPCSV response in the concentration range of 0.0025-84.0 mu g mL(-1) [detection limit (3 sigma) 1.49 ng mL(-1)]. The sensor was found to be highly selective for creatinine without any response of interferents viz., NaCl, urea, creatine, glucose, phenylalanine, tyrosine, histidine and cytosine. The non-imprinted polymer-modified electrode did not show linear response to creatinine. The imprinting factor as high as 9.4 implies that the imprinted polymer exclusively acts as a recognition element of creatinine sensor. The proposed procedure can be used to determine creatinine in human blood serum without any preliminary treatment of the sample in an accurate, rapid and simple way. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 280
页数:9
相关论文
共 50 条
  • [1] Ascorbic acid sensor based on molecularly imprinted polymer-modified hanging mercury drop electrode
    Prasad, B. B.
    Srivastava, S.
    Tiwari, K.
    Sharma, P. S.
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (04): : 1082 - 1087
  • [2] Barbituric acid sensor based on molecularly imprinted polymer-modified hanging mercury drop electrode
    Prasad, BB
    Lakshmi, D
    [J]. ELECTROANALYSIS, 2005, 17 (14) : 1260 - 1268
  • [3] Development of uric acid sensor based on molecularly imprinted polymer-modified hanging mercury drop electrode
    Lakshmi, Dhana
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    [J]. ELECTROANALYSIS, 2006, 18 (09) : 918 - 927
  • [4] Development of Uracil and 5-Fluorouracil Sensors Based on Molecularly Imprinted Polymer-Modified Hanging Mercury Drop Electrode
    Prasad, Bhim Bali
    Srivastava, Shrinkhala
    Tiwari, Khushaboo
    Sharma, Piyush Sindhu
    [J]. SENSORS AND MATERIALS, 2009, 21 (06) : 291 - 306
  • [5] Atrazine sensor based on molecularly imprinted polymer-modified gold electrode
    Shoji, R
    Takeuchi, T
    Kubo, I
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (18) : 4882 - 4886
  • [6] Development of a Creatinine Sensor Based on a Molecularly Imprinted Polymer-Modified Sol-Gel Film on Graphite Electrode
    Patel, Amit Kumar
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    [J]. ELECTROANALYSIS, 2008, 20 (19) : 2102 - 2112
  • [7] Imprinted polymer-modified hanging mercury drop electrode for differential pulse cathodic stripping voltammetric analysis of creatine
    Lakshmi, Dhana
    Sharma, Piyush S.
    Prasad, Bhim B.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (12): : 3302 - 3308
  • [8] A Molecularly Imprinted Polymer-modified Potentiometric Sensor for the Detection of Glutathione
    Konishi, Atsuko
    Takegami, Shigehiko
    Kitade, Tatsuya
    [J]. ANALYTICAL SCIENCES, 2019, 35 (10) : 1111 - 1115
  • [9] A Molecularly Imprinted Polymer-modified Potentiometric Sensor for the Detection of Glutathione
    Atsuko Konishi
    Shigehiko Takegami
    Tatsuya Kitade
    [J]. Analytical Sciences, 2019, 35 : 1111 - 1115
  • [10] Voltammetric sensor for vanillylmandelic acid based on molecularly imprinted polymer-modified electrodes
    Blanco-López, MC
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (04): : 353 - 362