Desert-Based Absolute Calibration of Successive Geostationary Visible Sensors Using a Daily Exoatmospheric Radiance Model

被引:33
|
作者
Bhatt, Rajendra [1 ]
Doelling, David R. [2 ]
Morstad, Daniel [1 ]
Scarino, Benjamin R. [1 ]
Gopalan, Arun [1 ]
机构
[1] Sci Syst & Applicat Inc, Hampton, VA 23666 USA
[2] NASA, Langley Res Ctr, Climate Sci Branch, Hampton, VA 23681 USA
来源
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING | 2014年 / 52卷 / 06期
基金
美国国家航空航天局;
关键词
Geostationary visible imager calibration; pseudoinvariant calibration targets; spectral band adjustment factor (SBAF); CHANNELS; DEGRADATION; METEOSAT;
D O I
10.1109/TGRS.2013.2274594
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A desert daily exoatmospheric radiance model (DERM) based on a well-calibrated (reference) geostationary Earth orbit (GEO) satellite visible sensor can be used to transfer the calibration to a (target) GEO sensor located at the same equatorial longitude location. The DERM is based on the reference GEO daily radiances observed over a single pseudoinvariant calibration site (PICS) being that the daily angular conditions are repeated annually for any historical or successive colocated GEO. The GEO-specific PICSs used in the study are first inspected using the well-calibrated Aqua-MODerate Resolution Imaging Spectroradiometer (MODIS) exoatmospheric reflectances for stability. The Libyan Desert site was found to be stable within 1% over ten years. The average clear-sky daily local-noon interannual variability based on Meteosat-9 0.65-mu m top-of-atmosphere radiances over the Libyan Desert is 0.74%, which implies that the combined surface and atmospheric column is invariant. A spectral band adjustment factor, based on Scanning Imaging Absorption Spectrometer for Atmospheric Cartography spectral radiances, is used to account for sensor spectral response function (SRF) differences between the reference and target GEO. The GEO reference calibration was based on the GEO/Aqua-MODIS ray-matched radiance intercalibration transfer technique. The reference Meteosat-9 DERM and ray-matched calibration consistency was within 0.4% and 1.9% for Meteosat-8 and Meteosat-7, respectively. Similarly, GOES-10 and GOES-15 were calibrated based on the GOES-11 DERM using the Sonoran Desert and were found to have a consistency within 1% and 3%, respectively.
引用
收藏
页码:3670 / 3682
页数:13
相关论文
共 10 条
  • [1] DESERT BASED ABSOLUTE CALIBRATION OF VISIBLE SENSORS
    Bhatt, Rajendra
    Doelling, David R.
    Scarino, Benjamin R.
    Morstad, Daniel L.
    2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 7015 - 7018
  • [2] Evaluation of ISCCP Multisatellite Radiance Calibration for Geostationary Imager Visible Channels Using the Moon
    Stone, Thomas C.
    Rossow, William B.
    Ferrier, Joseph
    Hinkelman, Laura M.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03): : 1255 - 1266
  • [3] Absolute radiance calibration in the UV and visible spectral range using atmospheric observations during twilight
    Wagner, Thomas
    Pukite, Janis
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (01) : 277 - 297
  • [4] REFLECTANCE-BASED AND RADIANCE-BASED METHODS FOR THE IN-FLIGHT ABSOLUTE CALIBRATION OF MULTISPECTRAL SENSORS
    SLATER, PN
    BIGGAR, SF
    HOLM, RG
    JACKSON, RD
    MAO, Y
    MORAN, MS
    PALMER, JM
    YUAN, B
    REMOTE SENSING OF ENVIRONMENT, 1987, 22 (01) : 11 - 37
  • [5] CROSS-CALIBRATION OF IMAGING SENSORS USING MODEL-BASED, SI-TRACEABLE PREDICTIONS OF AT-SENSOR RADIANCE
    Thome, Kurtis
    McCorkel, Joel
    EARTH OBSERVING SYSTEMS XVII, 2012, 8510
  • [6] Calibration Framework based on Bluetooth Sensors for Traffic State Estimation using a Velocity based Cell Transmission Model
    Allstrom, Andreas
    Bayen, Alexandre M.
    Fransson, Magnus
    Gundlegard, David
    Patire, Anthony D.
    Rydergren, Clas
    Sandin, Mats
    17TH MEETING OF THE EURO WORKING GROUP ON TRANSPORTATION, EWGT2014, 2014, 3 : 972 - 981
  • [7] Absolute vicarious calibration of OCM2 and AWiFS sensors using a reflectance-based method over land sites in the Rann of Kutch, Gujarat
    Sridhar, V. N.
    Mehta, Kaushal B.
    Prajapati, R. P.
    Babu, K. N.
    Suthar, N. M.
    Shukla, A. K.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2013, 34 (16) : 5690 - 5708
  • [8] Robust, Model-Based External Calibration of Multi-Channel Airborne SAR Sensors Using Range Compressed Raw Data
    Jaeger, Marc
    Scheiber, Rolf
    Reigber, Andreas
    REMOTE SENSING, 2019, 11 (22)
  • [9] Daily-Scale Runoff Simulation of Shanxi Drinking Water Based on SWAT Model, Using Separation Dry and Wet Season Calibration Method
    Liu, Yuanyuan
    Xing, Fang
    Zhou, Peipei
    Sun, Chao
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2023, 32 (03): : 2221 - 2230
  • [10] High-resolution spatially explicit land surface model calibration using field-scale satellite-based daily evapotranspiration product
    Yang, Yi
    Guan, Kaiyu
    Peng, Bin
    Pan, Ming
    Jiang, Chongya
    Franz, Trenton E.
    JOURNAL OF HYDROLOGY, 2021, 596