Influence of specimen thickness on the nanoindentation of hydrogels: Measuring the mechanical properties of soft contact lenses

被引:28
|
作者
Selby, Alastair [1 ]
Maldonado-Codina, Carole [2 ]
Derby, Brian [1 ]
机构
[1] Univ Manchester, Sch Mat, Manchester M13 9PL, Lancs, England
[2] Univ Manchester, Fac Life Sci, Eurolens Res, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
ELASTIC PROPERTIES; INDENTATION; MODULUS; MICROINDENTATION; RELAXATION; POLYMERS; ADHESION; FILMS; LOAD;
D O I
10.1016/j.jmbbm.2013.11.023
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nanoindentation offers a convenient method for the testing of thin hydrogel specimens, such as contact lenses, to directly assess their mechanical properties. Here we investigate the mechanical properties of poly(hydroxyethyl methacrylate) (pHEMA) specimens of a range of uniform thickness values and demonstrate that, with 50 and 100 mu m radius spherical indenters, a significant increase in apparent elastic modulus is seen when the specimen thickness is smaller than 500 mu m at indentation depths <1 mu m. This is a manifestation of the well known indentation thickness effect but occurring at larger critical thicknesses than seen with other materials. A simple empirical relation is determined for the variation in apparent elastic modulus with normalised thickness. The empirical thickness correction function obtained from pHEMA specimens was subsequently used to correct for the thickness variation within a range of contact lenses supplied by a number of different manufacturers fabricated from both pHEMA and silicone polymers, with a range of optical strengths and hence thickness profiles. The correction function is seen to compensate for the variation in apparent elastic modulus with lens thickness for all four contact lens types, irrespective of lens material. The measured Young's modulus of the contact lens material, corrected for thickness, was compared with that quoted by the manufacturers of the contact lenses, obtained by conventional bulk mechanical testing, to find good agreement. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 50 条
  • [1] POLYMERIC HYDROGELS FOR SOFT CONTACT-LENSES
    SINGH, J
    AGRAWAL, K
    RAY, AR
    SINGHAL, JP
    SINGH, H
    DADA, VK
    MEHTA, MR
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (09): : 1253 - 1257
  • [2] Obtaining full contact for measuring polydimethylsiloxane mechanical properties with flat punch nanoindentation
    De Paoli, Federico
    Volinsky, Alex A.
    METHODSX, 2015, 2 : 374 - 378
  • [3] Mechanical properties of contact lenses
    Winkless, Laurie
    MATERIALS TODAY, 2015, 18 (01)
  • [4] Critical issues in measuring the mechanical properties of hard films on soft substrates by nanoindentation techniques
    Hay, JC
    Pharr, GM
    THIN-FILMS - STRESSES AND MECHANICAL PROPERTIES VII, 1998, 505 : 65 - 70
  • [5] Non-contact AFM with a nanoindentation technique for measuring the mechanical properties of thin films
    Chowdhury, S
    Laugier, MT
    NANOTECHNOLOGY, 2004, 15 (08) : 1017 - 1022
  • [6] CORNEAL THICKNESS IN EXTENDED WEAR OF SOFT CONTACT-LENSES
    HIRJI, NK
    LARKE, JR
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1979, 63 (04) : 274 - 276
  • [7] Regional Changes in Corneal Thickness and Shape with Soft Contact Lenses
    Tyagi, Garima
    Collins, Michael
    Read, Scott
    Davis, Brett
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (08) : 567 - 575
  • [8] Static compression optical coherence elastography to measure the mechanical properties of soft contact lenses
    Quince, Zachery
    Alonso-Caneiro, David
    Read, Scott A.
    Collins, Michael J.
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (04) : 1821 - 1833
  • [9] INFLUENCE OF HARD AND SOFT HYDROPHILIC CONTACT-LENSES
    KILP, H
    ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1974, 190 (03): : 275 - 280
  • [10] A Nonintrusive Method of Measuring the Local Mechanical Properties of Soft Hydrogels Using Magnetic Microneedles
    Chippada, Uday
    Yurke, Bernard
    Georges, Penelope C.
    Langrana, Noshir A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (02):