Temporally and Spatially Constrained ICA of fMRI Data Analysis

被引:14
|
作者
Wang, Zhi [1 ,2 ,3 ]
Xia, Maogeng [1 ,2 ,3 ]
Jin, Zhen [5 ]
Yao, Li [1 ,2 ,3 ,4 ]
Long, Zhiying [1 ,2 ,3 ]
机构
[1] Beijing Normal Univ, State Key Lab Cognit Neurosci & Learning, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, IDG McGovern Inst Brain Res, Beijing 100875, Peoples R China
[3] Beijing Normal Univ, Ctr Collaborat & Innovat Brain & Learning Sci, Beijing 100875, Peoples R China
[4] Beijing Normal Univ, Sch Informat Sci & Technol, Beijing 100875, Peoples R China
[5] Beijing 306 Hosp, Lab Magnet Resonance Imaging, Beijing, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 04期
基金
中国国家自然科学基金;
关键词
INDEPENDENT COMPONENT ANALYSIS; FIXED-POINT ALGORITHMS; GENERAL LINEAR-MODEL; BLIND SEPARATION; PROJECTION;
D O I
10.1371/journal.pone.0094211
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Constrained independent component analysis (CICA) is capable of eliminating the order ambiguity that is found in the standard ICA and extracting the desired independent components by incorporating prior information into the ICA contrast function. However, the current CICA method produces constraints that are based on only one type of prior information (temporal/spatial), which may increase the dependency of CICA on the accuracy of the prior information. To improve the robustness of CICA and to reduce the impact of the accuracy of prior information on CICA, we proposed a temporally and spatially constrained ICA (TSCICA) method that incorporated two types of prior information, both temporal and spatial, as constraints in the ICA. The proposed approach was tested using simulated fMRI data and was applied to a real fMRI experiment using 13 subjects who performed a movement task. Additionally, the performance of TSCICA was compared with the ICA method, the temporally CICA (TCICA) method and the spatially CICA (SCICA) method. The results from the simulation and from the real fMRI data demonstrated that TSCICA outperformed TCICA, SCICA and ICA in terms of robustness to noise. Moreover, the TSCICA method displayed better robustness to prior temporal/spatial information than the TCICA/SCICA method.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Temporally constrained ICA with threshold and its application to fMRI data
    Long, Zhiying
    Wang, Zhi
    Zhang, Jing
    Zhao, Xiaojie
    Yao, Li
    [J]. BMC MEDICAL IMAGING, 2019, 19 (1)
  • [2] Temporally constrained ICA with threshold and its application to fMRI data
    Zhiying Long
    Zhi Wang
    Jing Zhang
    Xiaojie Zhao
    Li Yao
    [J]. BMC Medical Imaging, 19
  • [3] Constrained Spatiotemporal ICA and Its Application for fMRI Data Analysis
    Rasheed, Tahir
    Lee, Young-Koo
    Kim, Tae-Seong
    [J]. 13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 555 - +
  • [4] Fixed-point algorithms for constrained ICA and their applications in fMRI data analysis
    Wang, Ze
    [J]. MAGNETIC RESONANCE IMAGING, 2011, 29 (09) : 1288 - 1303
  • [5] A Sparse and Spatially Constrained Generative Regression Model for fMRI Data Analysis
    Oikonomou, Vangelis P.
    Blekas, Konstantinos
    Astrakas, Loukas
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (01) : 58 - 67
  • [6] A spatially robust ICA algorithm for multiple fMRI data sets
    Lukic, AS
    Wernick, MN
    Hansen, LK
    Anderson, J
    Strother, SC
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 839 - 842
  • [7] SCTICA: Sub-packet constrained temporal ICA method for fMRI data analysis
    Shi, Yuhu
    Zeng, Weiming
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 102 : 75 - 85
  • [8] Evaluation of ICA methods for fMRI data analysis
    Caprihan, A
    Anderson, LK
    [J]. NEUROIMAGE, 2001, 13 (06) : S89 - S89
  • [9] Spatially local and temporally smooth PCA for fMRI
    Ulfarsson, Magnus O.
    Solo, Victor
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 2853 - +
  • [10] Temporally constrained ICA: An application to artifact rejection in electromagnetic brain signal analysis
    James, CJ