Characterization of the exradin W1 plastic scintillation detector for small field applications in proton therapy

被引:18
|
作者
Hoehr, C. [1 ,2 ]
Lindsay, C. [1 ,2 ]
Beaudry, J. [3 ]
Penner, J. [3 ,4 ]
Strgar, V [3 ]
Lee, R. [3 ]
Duzenli, C. [3 ,5 ]
机构
[1] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada
[2] Univ Victoria, Victoria, BC, Canada
[3] BC Canc, Vancouver, BC, Canada
[4] Natl Univ Ireland, Galway, Ireland
[5] Univ British Columbia, Vancouver, BC, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 09期
关键词
plastic scintillation dosimeter; proton therapy; small field dosimetry; small proton fields; ocular proton therapy; OPTIC; ENERGY BEAM DOSIMETRY; VIVO SKIN DOSIMETRY; MED; PHYS; 42; OPTICAL-FIBERS; RADIOTHERAPY; MELANOMA; ELECTRON; OUTCOMES; CENTERS; PHOTON;
D O I
10.1088/1361-6560/aabd2d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate dosimetry in small field proton therapy is challenging, particularly for applications such as ocular therapy, and suitable detectors for this purpose are sought. The Exradin W1 plastic scintillating fibre detector is known to out-perform most other detectors for determining relative dose factors for small megavoltage photon beams used in radiotherapy but its potential in small proton beams has been relatively unexplored in the literature. The 1 mm diameter cylindrical geometry and near water equivalence of the W1 makes it an attractive alternative to other detectors. This study examines the dosimetric performance of the W1 in a 74 MeV proton therapy beam with particular focus on detector response characteristics relevant to relative dose measurement in small fields suitable for ocular therapy. Quenching of the scintillation signal is characterized and demonstrated not to impede relative dose measurements at a fixed depth. The background cable-only (cerenkov and radio-fluorescence) signal is 4 orders of magnitude less than the scintillation signal, greatly simplifying relative dose measurements. Comparison with other detectors and Monte Carlo simulations indicate that the W1 is useful for measuring relative dose factors for field sizes down to 5 mm diameter and shallow spread out Bragg peaks down to 6 mm in depth.
引用
收藏
页数:12
相关论文
共 33 条
  • [1] Proton Beam Entrance Dosimetry with the Exradin W1 Plastic Scintillation Detector
    Wootton, L.
    Holmes, C.
    Sahoo, N.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3727 - 3727
  • [2] Study On the Magnetic Field Effect On the Exradin W1 Plastic Scintillation Detector
    Wen, Z.
    Therriault-Proulx, F.
    Owens, C.
    Ibbott, G.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3417 - 3417
  • [3] Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy
    Alsanea, Fahed
    Wootton, Landon
    Sahoo, Narayan
    Kudchadker, Rajat
    Mahmood, Usama
    Beddar, Sam
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 47 : 58 - 63
  • [4] In Vivo Skin Dosimetry Using the Exradin W1 Plastic Scintillation Detector for Passively Scattered Proton Beam Therapy
    Alsanea, F.
    Wootton, L.
    Kudchadker, R.
    Usama, M.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3446 - 3446
  • [5] Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry
    Galavis, Paulina E.
    Hu, Lei
    Holmes, Shannon
    Das, Indra J.
    [J]. MEDICAL PHYSICS, 2019, 46 (05) : 2468 - 2476
  • [6] Quality Assurance for Gamma Knife Perfexion Using the Exradin W1 Plastic Scintillation Detector
    Pino, R.
    Therriault-Proulx, F.
    Yang, J.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 336 - 336
  • [7] Characterization of Exradin W1 plastic scintillator for output factors measurements in small field photon beams
    Petrucci, A.
    Consorti, R.
    Mangiacotti, F. P.
    Pressello, M. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S744 - S744
  • [8] Quality assurance for Gamma Knife Perfexion using the Exradin W1 plastic scintillation detector and Lucy phantom
    Therriault-Proulx, Francois
    Pino, Ramiro
    Yang, James N.
    Beddar, A. Sam
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [9] Patients in vivo skin dosimetry using the Exradin W1 plastic scintillator for proton therapy
    Alsanea, F.
    Wootton, L.
    Sahoo, N.
    Beddar, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S383 - S384
  • [10] On the accuracy of the Exradin W1 and the spectrum calibration method in scintillation dosimetry for small fields
    Papaconstadopoulos, P.
    Archambault, L.
    Seuntjens, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S71 - S72