Discrepancies in anthropometric parameters between different models affect intervertebral rotations when loading finite element models with muscle forces from inverse static analyses

被引:5
|
作者
Zhu, Rui [1 ,2 ]
Rohlmann, Antonius [1 ]
机构
[1] Charite, Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[2] Tongji Univ, Tongji Hosp, Sch Med, Dept Spine Surg, Shanghai 200065, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
finite element analysis; inverse static analysis; muscle forces; sensitivity; spine; LIGAMENTOUS LUMBAR SPINE; IN-VIVO; THORACOLUMBAR SPINE; EULER STABILITY; ORIENTATION; PREDICTION; VERTEBRAE; SHAPE;
D O I
10.1515/bmt-2013-0121
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In only a few published finite element (FE) simulations have muscle forces been applied to the spine. Recently, muscle forces determined using an inverse static (IS) model of the spine were transferred to a spinal FE model, and the effect of methodical parameters was investigated. However, the sensitivity of anthropometric differences between FE and IS models, such as body height and spinal orientation, was not considered. The aim of this sensitivity study was to determine the influence of those differences on the intervertebral rotations (IVRs) following the transfer of muscle forces from an IS model to a FE model. Muscle forces were estimated for 20 degrees flexion and 10 degrees extension of the upper body using an inverse static musculoskeletal model. These forces were subsequently transferred to a nonlinear FE model of the spino-pelvic complex, which includes 243 muscle fascicles. Deviations of body height (+/- 10 cm), spinal orientation in the sagittal plane (+/- 10 degrees), and body weight (+/- 10 kg) between both models were intentionally generated, and their influences on IVRs were determined. The changes in each factor relative to their corresponding reference value of the IS model were calculated. Deviations in body height, spinal orientation, and body weight resulted in maximum changes in the IVR of 19.2%, 26% and 4.2%, respectively, relative to T12-S1 IVR. When transferring muscle forces from an IS to a FE model, it is crucial that both models have the same spinal orientation and height. Additionally, the body weight should be equal in both models.
引用
收藏
页码:197 / 202
页数:6
相关论文
共 2 条
  • [1] Considerations when loading spinal finite element models with predicted muscle forces from inverse static analyses
    Zhu, Rui
    Zander, Thomas
    Dreischarf, Marcel
    Duda, Georg N.
    Rohlmann, Antonius
    Schmidt, Hendrik
    JOURNAL OF BIOMECHANICS, 2013, 46 (07) : 1376 - 1378
  • [2] The significance of using anthropometric parameters and postures of European drivers as a database for finite-element models when calculating spinal forces during whole-body vibration exposure
    Hinz, B.
    Seidel, H.
    Hofmann, J.
    Menzel, G.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2008, 38 (9-10) : 816 - 843