Individual and simultaneous voltammetric determination of ascorbic acid, uric acid and folic acid by using a glassy carbon electrode modified with gold nanoparticles linked to bentonite via cysteine groups

被引:26
|
作者
Yadav, Dharmendra Kumar [1 ]
Gupta, Rupali [1 ]
Ganesan, Vellaichamy [1 ]
Sonkar, Piyush Kumar [1 ]
机构
[1] Banaras Hindu Univ, Inst Sci, Dept Chem, Varanasi 221005, Uttar Pradesh, India
关键词
X-ray photoelectron spectroscopy; Energy dispersive X-ray analysis; X-ray diffraction; Cyclic voltammetry; Differential pulse voltammetry; Ion-exchange; CLAY-MODIFIED ELECTRODES; ELECTROCHEMICAL SENSING PLATFORM; AMINO-ACID; DOPAMINE; NANOCOMPOSITE; BIOSENSORS; COMPOSITE; NITRITE; NITROBENZENE; PEPTIDE;
D O I
10.1007/s00604-017-2186-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A voltammetric sensor for both the individual and the simultaneous determination of ascorbic acid (AA), uric acid (UA) and folic acid (FA) is described. It is based on a glassy carbon electrode (GCE) that was modified with bentonite (Bnt) that was first functionalized with cysteine (Cys) to which gold nanoparticles were linked. The resulting material (referred to as Au-Cys-Bnt) and the other materials were characterized by UV-vis spectroscopy, powder X-ray diffraction (XRD), scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray analysis and electrochemical methods. The XRD peak positions of bentonite and Cys-functionalized bentonite prove the incorporation of Cys into bentonite. The XPS spectrum of Au-Cys-Bnt confirms the interaction of gold nanoparticles with the thiol group of Cys. The modified GCE displays high electrocatalytic activity for the oxidation of AA, UA and FA, typically at 0.19, 0.41, and 0.73 V (vs. SCE), respectively. Differential pulse voltammetric data show a linear response that covers the 1 mu M to 25 mM concentration range for AA, the 1 to 200 mu M concentration range for UA, and two linear ranges for FA, one from 5 to 100 mu M and one from 100 mu M to 1.5 mM. The sensor was applied to the determination of AA, UA and FA in (spiked) multi-vitamin syrup, bird serum and milk samples.
引用
收藏
页码:1951 / 1957
页数:7
相关论文
共 50 条
  • [1] Individual and simultaneous voltammetric determination of ascorbic acid, uric acid and folic acid by using a glassy carbon electrode modified with gold nanoparticles linked to bentonite via cysteine groups
    Dharmendra Kumar Yadav
    Rupali Gupta
    Vellaichamy Ganesan
    Piyush Kumar Sonkar
    Microchimica Acta, 2017, 184 : 1951 - 1957
  • [2] Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode
    Liu, Ai-Lin
    Zhang, Shao-Bo
    Chen, Wei
    Lin, Xin-Hua
    Xia, Xing-Hua
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (10): : 1488 - 1495
  • [3] Electrocatalytic oxidation and simultaneous determination of uric acid and ascorbic acid on the gold nanoparticles-modified glassy carbon electrode
    Hu, Guangzhi
    Ma, Yonggen
    Guo, Yong
    Shao, Shijun
    ELECTROCHIMICA ACTA, 2008, 53 (22) : 6610 - 6615
  • [4] Modified Glassy Carbon Electrode with Polypyrrole Nanocomposite for the Simultaneous Determination of Ascorbic acid, Dopamine, Uric acid, and Folic Acid
    Ghanbari, Khadijeh
    Bonyadi, Sepideh
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01) : 68 - 83
  • [5] Glassy Carbon Electrode Modified with Gold Nanoparticles and DNA for the Simultaneous Determination of Uric Acid and Norepinephrine under Coexistence of Ascorbic Acid
    Liping Lu
    Xiangqin Lin
    Analytical Sciences, 2004, 20 : 527 - 530
  • [6] Glassy carbon electrode modified with gold nanoparticles and DNA for the simultaneous determination of uric acid and norepinephrine under coexistence of ascorbic acid
    Lu, LP
    Lin, XQ
    ANALYTICAL SCIENCES, 2004, 20 (03) : 527 - 530
  • [7] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092
  • [8] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502
  • [9] Simultaneous Voltammetric Determination of Ascorbic Acid, Dopamine and Uric Acid Using Polybromothymol Blue Film-Modified Glassy Carbon Electrode
    Xu, Xiongwei
    Lin, Qihuang
    Liu, Ailin
    Chen, Wei
    Weng, Xiuhua
    Wang, Changlian
    Lin, Xinhua
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (06) : 788 - 793
  • [10] Electrochemical sensor for simultaneous determination of ascorbic acid, uric acid and folic acid based on Mn-SnO2 nanoparticles modified glassy carbon electrode
    Lavanya, N.
    Fazio, E.
    Neri, F.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    Sekar, C.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 770 : 23 - 32