Detecting the quality of glycerol monolaurate: A method for using Fourier transform infrared spectroscopy with wavelet transform and modified uninformative variable elimination

被引:34
|
作者
Chen, Xiaojing [1 ,2 ]
Wu, Di [1 ]
He, Yong [1 ]
Liu, Shou [2 ]
机构
[1] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310029, Zhejiang, Peoples R China
[2] Xiamen Univ, Dept Phys, Xiamen 361005, Peoples R China
关键词
Fourier transform infrared spectroscopy; Glycerol monolaurate; Partial least squares; Wavelet transform; Uninformative information elimination; Simulated annealing; Nondestructive measurement; SUCCESSIVE PROJECTIONS ALGORITHM; PARTIAL LEAST-SQUARES; MULTIVARIATE CALIBRATION; SELECTION; CLASSIFICATION; OPTIMIZATION; SPECTROMETRY; REGRESSION; SPECTRA;
D O I
10.1016/j.aca.2009.02.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glycerol monolaurate (GML) products contain many impurities, such as lauric acid and glucerol. The GML content is an important quality indicator for GML production. A hybrid variable selection algorithm,which is a combination of wavelet transform (WT) technology and modified uninformative variable eliminate (MUVE) method, was proposed to extract useful information from Fourier transform infrared (FT-IR) transmission spectroscopy for the determination of GML content. FT-IR spectra data were compressed by WT first; the irrelevant variables in the compressed wavelet coefficients were eliminated by MUVE. In the MUVE process, simulated annealing (SA) algorithm was employed to search the optimal cutoff threshold. After the WT-MUVE process, variables for the calibration model were reduced front 7366 to 163. Finally, tire retained variables were employed as inputs of partial least squares (PLS) model to build the calibration model. For the prediction set, the correlation coefficient (r) of 0.9910 and root mean square error of prediction (RMSEP) of 4.8617 were obtained. The prediction result was better than the PLS model with full-spectra data. It was indicated that proposed WT-MUVE method Could not only make the prediction More accurate, but also make the calibration model more parsimonious. Furthermore, the reconstructed spectra represented the projection of the selected wavelet coefficients into the original domain, affording the chemical interpretation of the predicted results. It is Concluded that the FT-IR transmission spectroscopy technique with the proposed method is promising for the fast detection of GML content. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 50 条
  • [1] Rapid detection of the quality indicators in glycerol monolaurate products using Fourier transform infrared spectroscopy
    College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310029, China
    Guangxue Xuebao, 2008, 2 (326-330): : 326 - 330
  • [2] An Integration of Modified Uninformative Variable Elimination and Wavelet Packet Transform for Variable Selection
    Chen, Xiaojing
    Wu, Di
    He, Yong
    SPECTROSCOPY, 2011, 26 (04) : 42 - 47
  • [3] Determination of α-linolenic acid and linoleic acid in edible oils using near-infrared spectroscopy improved by wavelet transform and uninformative variable elimination
    Wu, Di
    Chen, Xiaojing
    Shi, Pinyan
    Wang, Sihan
    Feng, Fengqin
    He, Yong
    ANALYTICA CHIMICA ACTA, 2009, 634 (02) : 166 - 171
  • [4] A method for near-infrared spectral calibration of complex plant samples with wavelet transform and elimination of uninformative variables
    Xueguang Shao
    Fang Wang
    Da Chen
    Qingde Su
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1382 - 1387
  • [5] A method for near-infrared spectral calibration of complex plant samples with wavelet transform and elimination of uninformative variables
    Shao, XG
    Wang, F
    Chen, D
    Su, QD
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (05) : 1382 - 1387
  • [6] Determination of Apricot Fruit Quality Using Fourier Transform Infrared Spectroscopy
    Bureau, S.
    Reich, M.
    Gouble, B.
    Renard, C. M. G. C.
    Ruiz, D.
    Audergon, J. M.
    Bertrand, D.
    Lecomte, A.
    XIV INTERNATIONAL SYMPOSIUM ON APRICOT BREEDING AND CULTURE, 2010, 862 : 565 - 571
  • [7] Fourier transform infrared spectroscopy as a quality control tool
    Pandey, Girish C.
    Kulshreshtha, A.K.
    Process Control and Quality, 1993, 4 (02): : 109 - 123
  • [8] A rapid method for detecting bacterial polyhydroxyalkanoates in intact cells by Fourier transform infrared spectroscopy
    Hong, K
    Sun, S
    Tian, W
    Chen, GQ
    Huang, W
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1999, 51 (04) : 523 - 526
  • [9] VARIABLE FIELD OF VIEW FOURIER-TRANSFORM INFRARED SPECTROSCOPY
    HIRSCHFELD, T
    FATELEY, WG
    APPLIED SPECTROSCOPY, 1977, 31 (01) : 42 - 43
  • [10] A rapid method for detecting bacterial polyhydroxyalkanoates in intact cells by Fourier transform infrared spectroscopy
    K. Hong
    S. Sun
    W. Tian
    G. Q. Chen
    W. Huang
    Applied Microbiology and Biotechnology, 1999, 51 : 523 - 526