Standardization and harmonization in hematology: Instrument alignment, quality control materials, and commutability issue

被引:1
|
作者
Vidali, Matteo [1 ]
Carobene, Anna [2 ]
Apassiti Esposito, Sara [3 ]
Napolitano, Gavino [3 ]
Caracciolo, Alessandra [3 ]
Seghezzi, Michela [3 ]
Previtali, Giulia [3 ]
Lippi, Giuseppe [4 ]
Buoro, Sabrina [3 ]
机构
[1] Maggiore Carita Hosp, Clin Chem Unit, Novara, Italy
[2] Osped San Raffaele, Lab Med, Milan, Italy
[3] Hosp Papa Giovanni XXIII, Clin Chem Lab, Bergamo, Italy
[4] Univ Verona, Sect Clin Biochem, Verona, Italy
关键词
alignment; analytical quality; commutability; control material; hematologic analyzers; WORKING GROUP RECOMMENDATIONS; BLOOD-CELL COUNTS; BIOLOGICAL VARIATION; PARAMETERS; PERFORMANCE; HAEMIGLOBINCYANIDE; SPECIFICATIONS; VERIFICATION; LEUKOCYTES; PROTOCOL;
D O I
10.1111/ijih.13379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction In the hub and spoke laboratory network, the number of hematology analyzers (HAs) within each core center has increased, and the control of HAs alignment is becoming necessary requirement to ensure analytical quality. In this scenario, HA alignment can be assessed by analyzing the same control material used for internal quality control on multiple HAs, assuming its commutability. The aim of the study was to verify the applicability of a protocol for the alignment of HAs based on control material rather than on fresh whole-blood samples. Methods The alignment of five HAs was evaluated for red (RBC, Hb, MCV, RET), white (WBC, NE, LY, MO, EO, BA, IG), and platelet (PLT) series parameters, following a protocol by SIBioC, using human sample (HS) and quality control material (QC), after the verification of commutability, according to the IFCC protocol. Maximum bias was derived from biological variation data. Results A complete alignment between instruments was confirmed for the majority of the parameters investigated both for HS and QC material. Partial misalignments or inconcludent results were instead evident for MCV, MO, EO, BA, and IG. Interestingly, QC material was found to be not commutable for LY, MO, and BA. Conclusion The alignment of hematologic analyzers for main cell population parameters may be verified with both QC and HS, displaying consistent results and interpretation. The evaluation for some white series parameters (EO, BA, and IG) is critical, and particular attention must be paid to the values of the material used for the alignment.
引用
收藏
页数:8
相关论文
共 20 条
  • [1] Standardization and harmonization in hematology: Instrument alignment, quality control materials, and commutability issue
    Vidali, Matteo
    Carobene, Anna
    Esposito, Sara Apassiti
    Napolitano, Gavino
    Caracciolo, Alessandra
    Seghezzi, Michela
    Previtali, Giulia
    Lippi, Giuseppe
    Buoro, Sabrina
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (03) : 364 - 371
  • [2] Toward standardization of cardiac troponin I measurements part II: Assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays
    Christenson, Robert H.
    Duh, Show Hong
    Apple, Fred S.
    Bodor, Geza S.
    Bunk, David M.
    Panteghini, Mauro
    Welch, Michael J.
    Wu, Alan H. B.
    Kahn, Stephen E.
    CLINICAL CHEMISTRY, 2006, 52 (09) : 1685 - 1692
  • [3] Commutability and interchangeability of commercial quality control materials with feline plasma for common biochemical analytes
    Baral, Randolph M.
    Dhand, Navneet K.
    Freeman, Kathleen P.
    VETERINARY CLINICAL PATHOLOGY, 2016, 45 (02) : 300 - 310
  • [4] Commutability of control materials for external quality assessment of serum apolipoprotein A-I measurement
    Zeng, Jie
    Qi, Tianqi
    Wang, Shu
    Zhang, Tianjiao
    Zhou, Weiyan
    Zhao, Haijian
    Ma, Rong
    Zhang, Jiangtao
    Yan, Ying
    Dong, Jun
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (05) : 789 - 795
  • [5] Commutability of reference and control materials:an essential factor for assuring the quality of measurements in Laboratory Medicine
    Braga, Federica
    Panteghini, Mauro
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (07) : 967 - 973
  • [6] LACK OF COMMUTABILITY BETWEEN QUALITY CONTROL MATERIALS AND PLASMA SAMPLES IN A TROPONIN I ASSAY
    Candas-Estebanez, B.
    Cano-Corres, R.
    Dot-Bach, D.
    Valero-Politi, J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S713 - S713
  • [7] Evaluating Commutability of Control Materials in Three Nordic External Quality Assessment Schemes for Lipoproteins
    Norling, Anna
    Bokman, C. Fredrik
    Goransson, Emma
    Wande, Birgitta
    Pedersen, Morten M.
    Berghall, Heidi
    Svala, Emilia
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (06): : 1580 - 1591
  • [8] The study in whole blood quality control materials of hematology analyze
    Zhao, Lei
    Tang, Xiaoying
    Yan, Xiao
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 357 - 360
  • [9] PREPARATION OF QUALITY-CONTROL MATERIALS IN CLINICAL-CHEMISTRY AND HEMATOLOGY
    ANIDO, G
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1975, 68 (10): : 624 - 629
  • [10] ACCURATE ENZYME-ACTIVITY MEASUREMENTS - 2 DECADES OF DEVELOPMENT IN THE COMMUTABILITY OF ENZYME QUALITY-CONTROL MATERIALS
    REJ, R
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1993, 117 (04) : 352 - 364