DEVELOPMENT OF SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETERS: THE NESCOFI@BTF PROJECT

被引:14
|
作者
Bedogni, R. [1 ]
Gomez-Ros, J. M. [1 ,2 ]
Bortot, D. [1 ,3 ]
Pola, A. [3 ]
Introini, M. V. [3 ]
Esposito, A. [1 ]
Gentile, A. [1 ]
Mazzitelli, G. [1 ]
Buonomo, B. [1 ]
机构
[1] IFNF LNF, I-00044 Rome, Italy
[2] CIEMAT, E-28040 Madrid, Spain
[3] Politecn Milan, Dipartimento Energia, I-20133 Milan, Italy
基金
欧盟第七框架计划;
关键词
FIELDS;
D O I
10.1093/rpd/nct286
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
NESCOFI@BTF is a 3-y project (2011-13) supported by the Scientific Commission 5 of INFN (Italy). The target is the development of neutron spectrometers similar to the Bonner spheres, in terms of response energy interval and accuracy, but able to determine the neutron spectrum in only one exposure. These devices embed multiple (10 to 30) thermal neutron detectors (TNDs) within a single moderator. Two prototypes, called SPherical SPectrometer (SP2) and cylindrical spectrometer (CYSP), have been set up. Whilst SP2 has spherical geometry and nearly isotropic response, the CYSP has cylindrical geometry and is intended to be used as a directional spectrometer. Suitable active TNDs will be embedded in the final version of the devices. The resulting instruments could be used as real-time neutron spectrometers in neutron-producing facilities. This communication describes the design criteria, numerical analysis, experimental issues, state-of-the-art and future developments connected with the development of these instruments.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 8 条
  • [1] A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING
    Bedogni, R.
    Bortot, D.
    Buonomo, B.
    Esposito, A.
    Gomez-Ros, J. M.
    Introini, M. V.
    Mazzitelli, G.
    Moraleda, M.
    Pola, A.
    Romero, A. M.
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 326 - 330
  • [2] TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING
    Gomez-Ros, J. M.
    Bedogni, R.
    Bortot, D.
    Domingo, C.
    Esposito, A.
    Introini, M. V.
    Lorenzoli, M.
    Mazzitelli, G.
    Moraleda, M.
    Pola, A.
    Sacco, D.
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 104 - 110
  • [3] SINGLE-EXPOSURE NEUTRON TOMOGRAPHY OF 2-PHASE FLOW
    HUSSEIN, EMA
    MENELEY, DA
    BANERJEE, S
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1986, 12 (01) : 1 - 34
  • [4] A Review on the Development of Single-Moderator-Based Neutron Spectrometers
    Tursinah, Rasito
    Permana, Sidik
    Su'ud, Zaki
    Maulana, Alan
    Sukmabuana, Putu
    NUCLEAR TECHNOLOGY, 2025, 211 (04) : 635 - 644
  • [5] Single-exposure elemental differentiation and texture-sensitive phase-retrieval imaging with a neutron-counting microchannel-plate detector
    Arhatari, Benedicta D.
    Paganin, David M.
    Kirkwood, Henry
    Tremsin, Anton S.
    Gureyev, Timur E.
    Korsunsky, Alexander M.
    Kockelmann, Winfried
    Hofmann, Felix
    Huwald, Eric
    Zhang, Shu-Yan
    Kelleher, Joe
    Abbey, Brian
    PHYSICAL REVIEW A, 2024, 109 (05)
  • [6] Development of a new multi-walled carbon nanotube (MWCNT) aerosol generation and exposure system and confirmation of suitability for conducting a single-exposure inhalation study of MWCNT in rats
    Kasai, Tatsuya
    Gotoh, Kaoru
    Nishizawa, Tomoshi
    Sasaki, Toshiaki
    Katagiri, Taku
    Umeda, Yumi
    Toya, Tadao
    Fukushima, Shoji
    NANOTOXICOLOGY, 2014, 8 (02) : 169 - 178
  • [7] INSTAR DEVELOPMENT AND DISENGAGEMENT RATE OF ENGORGED FEMALE WINTER TICKS, DERMACENTOR-ALBIPICTUS (ACARI, IXODIDAE), FOLLOWING SINGLE-EXPOSURE AND TRICKLE-EXPOSURE OF MOOSE (ALCES-ALCES)
    DREW, ML
    SAMUEL, WM
    EXPERIMENTAL & APPLIED ACAROLOGY, 1989, 6 (03): : 189 - 196
  • [8] Dual-Source Single-Energy Multidetector CT Used to Obtain Multiple Radiation Exposure Levels within the Same Patient: Phantom Development and Clinical Validation
    Bellini, Davide
    Ramirez-Giraldo, Juan Carlos
    Bibbey, Alex
    Solomon, Justin
    Hurwitz, Lynne M.
    Farjat, Alfredo
    Mileto, Achille
    Samei, Ehsan
    Marin, Daniele
    RADIOLOGY, 2017, 283 (02) : 526 - 537