Lack of correlation between coronary blood flow and carotid intima media thickness

被引:11
|
作者
Arbel, Yaron [1 ]
Szekely, Yishay [1 ]
Berliner, Shlomo [2 ]
Hallevi, Hen [2 ]
Halkin, Amir [1 ]
Herz, Itzhak [1 ]
Keren, Gad [1 ]
Bazan, Shmuel [1 ]
Bornstein, Natan [2 ]
Banai, Shmuel [1 ]
Finkelstein, Ariel [1 ]
机构
[1] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sackler Sch Med, Dept Cardiol, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sackler Sch Med, IL-69978 Tel Aviv, Israel
关键词
Normal coronary arteries; coronary flow; TIMI frame count; carotid intima-media thickness; smoking; slow flow; ACUTE MYOCARDIAL-INFARCTION; CARDIAC SYNDROME-X; TIMI FRAME COUNT; ANGINA-PECTORIS; SLOW-FLOW; ARTERY INTIMA; SMOKING-CESSATION; DISEASE; OUTCOMES; ATHEROSCLEROSIS;
D O I
10.3233/CH-141808
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The phenomenon of slow coronary flow (SCF) in the presence of normal coronary arteries may indicate endothelial dysfunction, which is characteristic of an early stage in the development of atherosclerosis. Measurement of the Carotid Intima-Media Thickness (CIMT) allows identification of early stages of atherosclerosis. CIMT might offer a non-invasive method of diagnosing SCF patients. Previous studies demonstrated conflicting results regarding the relationship between these two phenomena. In the present study, we examined the association between coronary flow velocity and the degree of CIMT in patients with angiographically normal coronary arteries. METHODS: Coronary arterial blood flow velocity was measured using two methods - Corrected Thrombolysis in Myocardial Infarction (TIMI) Frame Count (CTFC) and Coronary Clearance Frame Count (CCFC). In addition, we measured the level of the CIMT using a special automated computerized software. RESULTS: Seventy Five consecutive patients were prospectively recruited. No correlation was found between CIMT and mean CTFC (r=-0.08, p=NS) or mean CCFC (r=-0.07, p=NS). In addition, CIMT values did not differ between the SCF and the Normal coronary flow (NCF) groups (0.796mm vs. 0.805 mm, respectively, p=0.733). Patients with SCF had higher levels of hematocrit (39.9% vs. 36.1%, p < 0.001), LDL cholesterol (101.1 mg/dl vs. 85.8 mg/dl, p=0.01) and higher rate of current smokers (28.9% vs. 10.8%, p=0.05). CONCLUSIONS: Patients with angiographically normal coronary arteries and SCF do not have increased CIMT values. However, current smoking, higher LDL cholesterol and hematocrit levels are all related to slower coronary blood flow.
引用
收藏
页码:371 / 381
页数:11
相关论文
共 50 条
  • [1] Relationship between the slow coronary flow and carotid artery intima-media thickness
    Avsar, Oezuer
    Demir, Ibrahim
    Ekiz, Oezguer
    Altekin, R. Emre
    Yalcinkaya, Selim
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2007, 7 (01): : 19 - 23
  • [2] Correlation between carotid intima media thickness and syntax score
    Ghany, Mohamed Abdel
    Wakeel, Mohamed Abdel
    Roushdy, Salwa
    Hasan-Ali, Hosam
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2017, 19 (0F) : F3 - F4
  • [3] CORRELATION BETWEEN ESSENTIAL HYPERTENSION AND CAROTID INTIMA MEDIA THICKNESS IN CHILDREN
    Popovici, Bianca
    Brumaru, O.
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2011, 115 (01): : 85 - 90
  • [4] Apolipoproteins: Correlation with carotid intima-media thickness and coronary artery disease
    Vladimirova-Kitova, L.
    ATHEROSCLEROSIS SUPPLEMENTS, 2006, 7 (03) : 258 - 258
  • [5] Correlation between SYNTAX score and carotid intima-media thickness in patients with chronic coronary syndrome
    Djuric, P.
    Obradovic, S.
    Spasic, M.
    Prokic, D. J.
    Mladenovic, Z.
    Jovic, Z.
    Subota, V
    Kocijancic, J. Maric
    Djuric, D.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1262 - 1262
  • [6] Association between Blood Pressure and Carotid Intima-Media Thickness
    Lim, Sun Min
    Kim, Hyeon Chang
    Lee, Hoon Sang
    Lee, Joo Young
    Suh, Mina
    Ahn, Song Vogue
    JOURNAL OF PEDIATRICS, 2009, 154 (05): : 667 - 671
  • [7] Correlation between coronary calcium score and intima-media thickness at carotid arteries in patients with coronary artery disease
    Pasowicz, M
    Kablak-Ziembicka, A
    Konieczynska, M
    Klimeczek, P
    Banys, R
    Przewlocki, T
    Podolec, P
    EUROPEAN HEART JOURNAL, 2002, 23 : 696 - 696
  • [8] The correlation of irregularities in carotid arterial intima-media thickness with coronary artery disease
    Ishizu, T
    Ishimitsu, T
    Kamiya, H
    Seo, Y
    Moriyama, N
    Obara, K
    Watanabe, S
    Yamaguchi, I
    HEART AND VESSELS, 2002, 17 (01) : 1 - 6
  • [9] CORRELATION BETWEEN CAROTID INTIMA MEDIA THICKNESS AND NEWLY DIAGNOSED HYPERTENSIVE PATIENTS
    Bhuyan, Rupak
    Das, Gaurav Chayan
    Mandal, Arabinda
    Pegu, David
    Deori, Indrani
    Ujawane, Sumit
    Pohlong, Stephenson
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (75): : 13049 - 13056
  • [10] Is there a correlation between OSAS duration/severity and carotid intima-media thickness?
    Ciccone, M. M.
    Scicchitano, P.
    Zito, A.
    Gesualdo, M.
    Damiani, M. F.
    Caputo, P.
    Bulzis, G.
    Riccardi, R.
    Resta, O.
    Carratu, P.
    EUROPEAN HEART JOURNAL, 2012, 33 : 133 - 133