Hip-Knee-Ankle (HKA) angle modification during gait in healthy subjects

被引:11
|
作者
Clement, Julien [1 ,2 ]
Blakeney, William [1 ]
Hagemeister, Nicola [2 ]
Desmeules, Francois [1 ]
Mezghani, Neila [2 ,3 ]
Lowry, Veronique [1 ]
Vendittoli, Pascal-Andre [1 ]
机构
[1] Univ Montreal, Hop Maisonneuve Rosemt, 541-5 Blvd Assompt, Montreal, PQ H1T 2M4, Canada
[2] Ctr Hosp Univ Montreal, Ecole Technol Super, Ctr Rech, Lab Rech Imagerie & Orthopedie, Tour Viger,900 Rue St Denis,Local R11-322, Montreal, PQ H2X 0A9, Canada
[3] Univ TELUQ, Ctr Rech LICEF, 5800,Rue St Denis,Bur 1105, Montreal, PQ H2S 3L5, Canada
关键词
Healthy subjects; 3D knee kinematics; Dynamic hip-knee-angle; KneeKG (TM) system; MECHANICAL AXIS ALIGNMENT; JOINT LINE; ADDUCTION MOMENT; FOLLOW-UP; KINEMATICS; SURVIVAL; LOAD; SYSTEM; TKA;
D O I
10.1016/j.gaitpost.2019.05.025
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Achieving a neutral static Hip-Knee-Ankle angle (sHKA) measured on radiographs has been considered a factor of success for total knee arthroplasty (TKA). However, recent studies have shown that sHKA seems to have no effect on TKA survivorship. sHKA is not representative of the dynamic loading occurring during gait, unlike the dynamic HKA (dHKA). Research question: The primary objective was to see if the sHKA is predictive of the dynamic HKA (dHKA). A secondary objective was to document to what degree the dHKA changes during gait. Methods: We analysed 3D knee kinematics during gait of a cohort of 90 healthy individuals with the KneeKG (TM) system. dHKA was calculated and compared with sHKA. Knees were considered "Stable" if the dHKA remained in valgus or varus for greater than 95% of the corresponding phase, and "Changer" otherwise. Patient characteristics of the Stable and Changer knees were compared to find associated factors. Results: Absolute variation of dHKA during gait was 10.9 +/- 5.3 degrees for the whole cohort. The variation was less for the varus knees (10.3 +/- 4.8 degrees), than for the valgus knees (12.8 +/- 6.1 degrees, p = 0.008). We found low to moderate correlations (r = 0.266 to 0.553, p < 0.001) between sHKA and dHKA values for varus knees and no significant correlation for valgus knees. Twenty two percent (36/165) of the knees were considered Changers. The proportion of knees that were Changers was 15% of the varus versus 39% of the valgus (p < 0.001). Significance: Lower limb radiographic measures of coronal alignment have limited value for predicting dynamic measures of alignment during gait.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [1] A Comparison of Dynamic and Static Hip-Knee-Ankle Angle during Gait in Knee Osteoarthritis Patients and Healthy Individuals
    Zhang, Li
    Liu, Geng
    Han, Bing
    Yan, Yuzhou
    Fei, Junhua
    Ma, Jianbing
    Zhang, Yunfei
    APPLIED BIONICS AND BIOMECHANICS, 2021, 2021
  • [2] A Comparison of Dynamic and Static Hip-Knee-Ankle Angle during Gait in Knee Osteoarthritis Patients and Healthy Individuals
    Zhang, Li
    Liu, Geng
    Han, Bing
    Yan, Yuzhou
    Fei, Junhua
    Ma, Jianbing
    Zhang, Yunfei
    Applied Bionics and Biomechanics, 2021, 2021
  • [3] Comparison of accuracy for hip-knee-ankle (HKA) angle by X-ray and knee motion analysis system and the relationships between HKA and gait posture
    Zhang, Hui
    Chen, Yanan
    Jiang, Huiquan
    Yan, Wenqing
    Ouyang, Yuanming
    Wang, Wei
    Liu, Yaru
    Zhou, Ying
    Gu, Shiyi
    Wan, Hong
    He, Axiang
    Mao, Yanjie
    Liu, Wanjun
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [4] Comparison of accuracy for hip-knee-ankle (HKA) angle by X-ray and knee motion analysis system and the relationships between HKA and gait posture
    Hui Zhang
    Yanan Chen
    Huiquan Jiang
    Wenqing Yan
    Yuanming Ouyang
    Wei Wang
    Yaru Liu
    Ying Zhou
    Shiyi Gu
    Hong Wan
    Axiang He
    Yanjie Mao
    Wanjun Liu
    BMC Musculoskeletal Disorders, 24
  • [5] A hip-knee-ankle exoskeleton emulator for studying gait assistance
    Bryan, Gwendolyn M.
    Franks, Patrick W.
    Klein, Stefan C.
    Peuchen, Robert J.
    Collins, Steven H.
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2021, 40 (4-5): : 722 - 746
  • [6] Arithmetic hip-knee-ankle angle and stressed hip-knee-ankle angle: equivalent methods for estimating constitutional lower limb alignment in kinematically aligned total knee arthroplasty
    Tarassoli, Payam
    Wood, Jil A.
    Chen, Darren B.
    Griffiths-Jones, Will
    Bellemans, Johan
    MacDessi, Samuel J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (09) : 2980 - 2990
  • [7] Arithmetic hip-knee-ankle angle and stressed hip-knee-ankle angle: equivalent methods for estimating constitutional lower limb alignment in kinematically aligned total knee arthroplasty
    Payam Tarassoli
    Jil A. Wood
    Darren B. Chen
    Will Griffiths-Jones
    Johan Bellemans
    Samuel J. MacDessi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 2980 - 2990
  • [8] Reliability and validity of OpenPose for measuring hip-knee-ankle angle in patients with knee osteoarthritis
    Saiki, Yoshitomo
    Kabata, Tamon
    Ojima, Tomohiro
    Kajino, Yoshitomo
    Inoue, Daisuke
    Ohmori, Takaaki
    Yoshitani, Junya
    Ueno, Takuro
    Yamamuro, Yuki
    Taninaka, Atsushi
    Kataoka, Tomoyuki
    Kubo, Naoyuki
    Hayashi, Seigaku
    Tsuchiya, Hiroyuki
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] Knee thrust prevalence and normative hip-knee-ankle angle deviation values among healthy individuals across the lifespan
    Palad, Y. Y.
    Leaver, A. M.
    McKay, M. J.
    Baldwin, J. N.
    Lunar, F. R. M.
    Caube, F. D. M.
    Burns, J.
    Simic, M.
    OSTEOARTHRITIS AND CARTILAGE, 2018, 26 (10) : 1326 - 1332
  • [10] Reliability and validity of OpenPose for measuring hip-knee-ankle angle in patients with knee osteoarthritis
    Yoshitomo Saiki
    Tamon Kabata
    Tomohiro Ojima
    Yoshitomo Kajino
    Daisuke Inoue
    Takaaki Ohmori
    Junya Yoshitani
    Takuro Ueno
    Yuki Yamamuro
    Atsushi Taninaka
    Tomoyuki Kataoka
    Naoyuki Kubo
    Seigaku Hayashi
    Hiroyuki Tsuchiya
    Scientific Reports, 13