The Boston Keratoprosthesis: Comparing Corneal Epithelial Cell Compatibility with Titanium and PMMA

被引:33
|
作者
Ament, Jared D. [1 ,2 ]
Spurr-Michaud, Sandra J. [1 ]
Dohlman, Claes H. [1 ,2 ]
Gipson, Ilene K. [1 ]
机构
[1] Harvard Univ, Sch Med, Schepens Eye Res Inst, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Massachusetts Eye & Ear Infirm, Boston, MA 02114 USA
关键词
Boston Keratoprosthesis; biomaterials; titanium; corneal cell compatibility; INTRAOCULAR LENSES; RESIDUAL MONOMER; BIOMATERIALS; CYTOTOXICITY; PARTICLES; RESINS;
D O I
10.1097/ICO.0b013e31819670ac
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine in vitro whether titanium is superior corneal cell compatibility to standard polymethyl-methacryl ate (PMMA) for the Boston Keratoprosthesis (KPro). Methods: Human corneal-limbal epithelial (HCLE) cells were Cultured 24, 48, 72 96, 120, 144. or 168 hours in culture plates alone (controls) or with PMMA or titanium discs. Experiments were performed in triplicate and repeated (final n = 6). To determine if a Soluble, toxic factor is emitted from materials, concurrent experiments at 48 and 144 hours were performed with discs placed in Transwell Supports, with HCLE cells plated beneath. As an additional test for soluble factors, cells were incubated 24 hours with disc-conditioned media, and number of viable cells per well was quantified at each timepoint by proliferation assay. To determine if delayed cell proliferation was attributable to cell death, HCLE cell death was measured under all conditions and quantified at each timepoint by cytotoxicity assay. The effects of material on HCLE cell proliferation over time was determined by repeated measures ANOVA. P < 0.05 was statistically significant. Results: HCLE cell proliferation was greater in wells with titanium discs compared to PMMA. Differences between the test discs and control non-disc cocultures were statistically significant over time for both cell proliferation (P = 0.001) and death (P = 0.0025). No significant difference Was found using Transwells (P = 0.9836) or disc-conditioned media (P = 0.36). Conclusion: This in vitro HCLE cell model demonstrates significantly increased cell proliferation and decreased cell death with cell/titanium contact compared to cell/PMNA contact. Moreover, differences are unlikely attributable to a soluble factor. Prospective in vivo analysis of the two KPro biomaterials is indicated.
引用
收藏
页码:808 / 811
页数:4
相关论文
共 50 条
  • [1] Titanium Boston keratoprosthesis with corneal cell adhesive and bactericidal dual coating
    Gomez, Silvia Gonzalez
    Guillem-Marti, Jordi
    Martin-Gomez, Helena
    Mas-Moruno, Carlos
    Ginebra, Maria-Pau
    Gil, Francisco Javier
    Barraquer, Rafael Ignasi
    Manero, Jose Maria
    BIOMATERIALS ADVANCES, 2023, 154
  • [2] Biointegration of collagen hydrogel, as donor corneal substitute, on PMMA for Boston keratoprosthesis
    Riau, Andri K.
    Mondal, Debasish
    Yam, Gary Hin-Fai
    Liedberg, Bo
    Venkatraman, Subbu S.
    Mehta, Jodhbir S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Titanium to enhance biointegration of the Boston Keratoprosthesis with corneal tissue: a study in rabbits
    Culla, Borja Salvador
    Jeong, Kyung Jae
    Chiang, Homer H.
    Chodosh, James
    Dohlman, Claes H.
    Kohane, Daniel S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] Titanium Coating of the Boston Keratoprosthesis
    Salvador-Culla, Borja
    Jeong, Kyung Jae
    Kolovou, Paraskevi Evi
    Chiang, Homer H.
    Chodosh, James
    Dohlman, Claes H.
    Kohane, Daniel S.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (02):
  • [5] The Boston Keratoprosthesis in the Management of Corneal Limbal Stem Cell Deficiency
    Sejpal, Kunjal
    Yu, Fei
    Aldave, Anthony J.
    CORNEA, 2011, 30 (11) : 1187 - 1194
  • [6] A Review of Corneal Melting after Boston Keratoprosthesis
    Robert, Marie-Claude
    Dohlman, Claes H.
    SEMINARS IN OPHTHALMOLOGY, 2014, 29 (5-6) : 349 - 357
  • [7] Novel materials to enhance corneal epithelial cell migration on keratoprosthesis
    Karkhaneh, Akbar
    Mirzadeh, Hamid
    Ghaffariyeh, Alireza
    Ebrahimi, Abdolali
    Honarpisheh, Nazafarin
    Hosseinzadeh, Masud
    Heidari, Mohammad Hossein
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (03) : 405 - 409
  • [8] The Boston keratoprosthesis in the management of corneal blindness: Indications and limitations
    Stolowy, N.
    Callet, M.
    Beylerian, M.
    Hoffart, L.
    Yin, G. Ho Wang
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (07): : 642 - 649
  • [9] Global Corneal Blindness and the Boston Keratoprosthesis Type I
    Ament, Jared D.
    Todani, Amit
    Pineda, Roberto, II
    Shen, Tueng T.
    Aldave, Anthony J.
    Dohlman, Claes H.
    Chodosh, James
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (04) : 537 - 539
  • [10] Retroprosthetic Membrane Formation in Boston Keratoprosthesis: A Case-Control-Matched Comparison of Titanium Versus PMMA Backplate
    Talati, Rushi K.
    Hallak, Joelle A.
    Karas, Faris I.
    de la Cruz, Jose
    Cortina, M. Soledad
    CORNEA, 2018, 37 (02) : 145 - 150