Acute Hemoptysis Following Cryoballoon Pulmonary Vein Isolation A Multicenter Study

被引:6
|
作者
Vogler, Julia [1 ]
Fink, Thomas [1 ,2 ]
Sohns, Christian [3 ]
Sommer, Philipp [3 ]
Pott, Alexander [4 ]
Dahme, Tillman [4 ]
Rottner, Laura [2 ]
Sciacca, Vanessa [1 ,2 ]
Sieren, Malte Maria [5 ]
Jacob, Fabian [5 ]
Barkhausen, Joerg [5 ]
Sano, Makoto [1 ]
Eitel, Charlotte [1 ,6 ]
Metzner, Andreas [2 ]
Ouyang, Feifan [2 ,7 ]
Kuck, Karl-Heinz [1 ,2 ,6 ]
Tilz, Roland Richard [1 ,2 ,6 ]
Heeger, Christian-Hendrik [1 ,2 ,6 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Cardiol, Med Clin 2, Lubeck, Germany
[2] Asklepios Klin St Georg, Dept Cardiol, Hamburg, Germany
[3] Ruhr Univ Bochum, Heart & Diabet Ctr North Rhine Westphalia, Dept Electrophysiol, Bad Oeynhausen, Germany
[4] Ulm Univ, Dept Med 2, Med Ctr, Ulm, Germany
[5] Univ Hosp Schleswig Holstein, Dept Radiol, Lubeck, Germany
[6] German Ctr Cardiovasc Res DZHK, Lubeck, Germany
[7] Fuwai Hosp, Dept Cardiol, Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
关键词
atrial fibrillation; bronchial injury; catheter ablation; cryoballoon; hemoptysis; pulmonary vein isolation; PHRENIC-NERVE PALSY; ATRIAL-FIBRILLATION; 2ND-GENERATION CRYOBALLOON; BONUS-FREEZE; RADIOFREQUENCY ABLATION; PREVENTION; INJURY; CRYOABLATION; OUTCOMES; BRONCHI;
D O I
10.1016/j.jacep.2020.02.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to assess the incidence, procedural characteristics, contributing factors, and clinical outcome of cryoballoon-based pulmonary vein isolation (CB-PVI)-related hemoptysis in a multicenter study. BACKGROUND Hemoptysis has been described as a rare complication of CB-PVI. However, the precise mechanism and the etiology of this complication are poorly characterized. METHODS Consecutive patients undergoing CB-PVI for paroxysmal or persistent atrial fibrillation at 4 German hospitals were included in this observational analysis. RESULTS A total of 4,331 CB-PVI procedures were performed between 2006 and 2019. Fifteen patients (9 men, mean age 68.1 +/- 9.8 years) developed acute hemoptysis during or within 24 h after CB-PVI, resulting in a hemoptysis frequency of 0.35%. Hemoptysis occurred in 6 of 720 procedures using the first-generation CB (0.83%) and in 9 of 3,611 procedures using the second-, third-, or fourth-generation CB (0.25%) (p 0.015). Bronchoscopy was performed in 8 patients and showed bleeding exclusively due to mucosal injury or due to a coagutum at a bronchus adjacent to the ablation site. Hemoptysis resolved spontaneously without any tong-term sequelae in all patients, except for a 92-year-old patient who died 13 days after CB-PVI due to pneumonia. No specific endobronchial treatment was necessary. CONCLUSIONS Acute hemoptysis after CB-PVI is a rare but potentially life-threatening complication that is usually self-limiting. Direct thermal injury of bronchi adjacent to a pulmonary vein seems to be the most likely mechanism. (C) 2020 by the American College of Cardiology Foundation.
引用
收藏
页码:773 / 782
页数:10
相关论文
共 50 条
  • [1] Early Hemoptysis Following Cryoballoon Pulmonary Vein Isolation: A Single Centre Experience
    Olgun, Fatih Erkam
    Kilicaslan, Fethi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 : S21 - S22
  • [2] Hemoptysis After Pulmonary Vein Isolation with a Cryoballoon: An Analysis of the Potential Etiology
    Bhagwandien, Rohit
    Van Belle, Yves
    De Groot, Natasja
    Jordaens, Luc
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (09) : 1067 - 1069
  • [3] Bronchial erosion and hemoptysis after pulmonary vein isolation by cryoballoon ablation
    van Opstal, J. M.
    Timmermans, C.
    Blaauw, Y.
    Pison, L.
    HEART RHYTHM, 2011, 8 (09) : 1459 - 1459
  • [4] Cryoballoon temperature predicts acute pulmonary vein isolation
    Fuernkranz, Alexander
    Koester, Ilka
    Chun, K. R. Julian
    Metzner, Andreas
    Mathew, Shibu
    Konstantinidou, Melanie
    Ouyang, Feifan
    Kuck, Karl Heinz
    HEART RHYTHM, 2011, 8 (06) : 821 - 825
  • [5] Cryoballoon pulmonary vein isolation
    Insulander, P.
    Tabrizi, F.
    Kenneback, G.
    Schwieler, J.
    Bastani, H.
    Braunschweig, F.
    Sadigh, B.
    Drca, N.
    Jensen-Urstad, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 273 - 274
  • [6] Hemoptysis Deja Vu for Cryoballoon Use for Pulmonary Vein Isolation for Atrial Fibrillation Ablation
    Kumar, Narendra
    Timmermans, Carl
    Pison, Laurent
    Crijns, Harry
    CHEST, 2014, 145 (06) : 1435 - 1435
  • [7] Predictors of hemoptysis in the setting of pulmonary vein isolation using the second-generation cryoballoon
    Wei, Hui-Qiang
    Guo, Xiao-Gang
    Zhou, Gong-Bu
    Sun, Qi
    Yang, Jian-Du
    Luo, Bin
    Ma, Jian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (07) : 958 - 965
  • [8] Biophysical Indicators of Acute Pulmonary Vein Isolation With a Novel Cryoballoon
    Anic, Ante
    Martin, Andrew
    Breskovic, Toni
    Ouss, Alexandre
    Dekker, Lukas
    Sulkin, Matthew
    Binh Tran
    Yap, Sing-Chien
    Bhagwandien, Rohit E.
    Lever, Nigel
    Varma, Niraj
    CIRCULATION, 2020, 142
  • [9] Hemoptysis as a Side Effect of Cryoballoon Pulmonary Vein Isolation in Atrial Fibrillation - A Retrospective Case-control Study
    Bullert, Kevin
    Gutleben, Klaus-Jurgen
    Horstkotte, Dieter
    Molatta, Stephan
    Korber, Britta
    Noelker, Georg
    CIRCULATION, 2016, 134
  • [10] Hemoptysis as a Side Effect of Cryoballoon Pulmonary Vein Isolation in Atrial Fibrillation - A Retrospective Case-control Study
    Bullert, Kevin
    Gutleben, Klaus-Jurgen
    Horstkotte, Dieter
    Molatta, Stephan
    Korber, Britta
    Noelker, Georg
    CIRCULATION, 2016, 134