A novel direct-conversion structure for non-contact vital sign detection system

被引:0
|
作者
Long, Jiang [1 ]
Gu, Changzhan [1 ]
Tao, Yong [1 ]
Huangfu, Jiangtao [1 ]
Qiao, S. [2 ]
Cui, W. Z. [3 ]
Ma, W. [3 ]
Ran, Lixin [1 ]
机构
[1] Zhejiang Univ, Dept Info Sci & Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Zhejiang Univ City Coll, Hangzhou 310027, Zhejiang, Peoples R China
[3] Xian Inst Space Radio Technol, Natl Key Lab Space Microwave Technol, Xian 710000, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, an analysis on non-contact vital sign detection system is presented. It is concluded that the null point and dc-offset are related, so that the associated problems can be solved. Based on this principle, a novel structure of direct-conversion transceiver, which contains a tuneable phase shifter, is proposed to achieve a better performance. Two sets of simulations are employed to demonstrate the new structure. With this structure, dc-offset and null point can be eliminated and it is very easy to reach the optimal detection.
引用
收藏
页码:1270 / +
页数:2
相关论文
共 50 条
  • [1] PXI-based Non-contact Vital Sign Detection System
    Banerjee, Sharmi
    Gu, Changzhan
    Li, Changzhi
    2014 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2014, : 4 - 6
  • [2] Non-contact Vital Sign Detection Using Gain Detection Technique
    Peng, Kang-Chun
    Sung, Meng-Che
    Wang, Fu-Kang
    Horng, Tzyy-Sheng
    2021 IEEE INTERNATIONAL SYMPOSIUM ON RADIO-FREQUENCY INTEGRATION TECHNOLOGY (RFIT), 2021,
  • [3] Design guidelines for radio frequency non-contact vital sign detection
    Li, Changzhi
    Xiao, Yanming
    Lin, Jenshan
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1651 - 1654
  • [4] Non-contact vital sign monitoring in the clinic
    Villarroel, Mauricio
    Jorge, Joao
    Pugh, Chris
    Tarassenko, Lionel
    2017 12TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION (FG 2017), 2017, : 278 - 285
  • [5] A Novel Microwave Measurement Technique for Non-contact Vital Sign Monitoring
    Sinharay, Arijit
    Das, Rajat
    Seth, Sayan
    2018 IEEE SENSORS, 2018, : 1515 - 1518
  • [6] Development of a novel infection screening system using non-contact vital sign monitoring technology
    Sun, Guanghao
    Matsuoka, Ayumu
    Miyata, Keisuke
    Vinh, Nguyen Quang
    Chen, Chris
    Ueda, Akiko
    Hakozaki, Yukiya
    Abe, Shigeto
    Kim, Seokjin
    Takei, Osamu
    Matsui, Takemi
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52
  • [7] Non-Contact Vital Sign Monitoring With a Metamaterial Surface
    Nguyen, Dat T.
    Zeng, Qihang
    Tian, Xi
    Ho, John S.
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 37 - 39
  • [8] Verification of a Non-Contact Vital Sign Monitoring System Using an Infant Simulator
    An, Yan
    Li, Changzhi
    Yu, Xiaogang
    Weiss, Michael D.
    Lin, Jenshan
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4836 - +
  • [9] System Level Integration of Handheld Wireless Non-Contact Vital Sign Detectors
    Yu, Xiaogang
    Li, Changzhi
    Lin, Jenshan
    RWS: 2009 IEEE RADIO AND WIRELESS SYMPOSIUM, 2009, : 487 - 490
  • [10] Bandwidth of non-contact vital sign detection with a noise suppression phase locked loop
    Xia, Zongyang
    Zhang, Ying
    NANOSENSORS, BIOSENSORS, AND INFO-TECH SENSORS AND SYSTEMS 2016, 2016, 9802