Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study

被引:62
|
作者
Richter, M
Amiot, LP
Neller, S
Kluger, P
Puhl, W
机构
[1] Univ Ulm, Dept Orthopaed & Spinal Cord Injury, D-89081 Ulm, Germany
[2] Univ Montreal, Hop Sacre Coeur, Dept Orthopaed, Montreal, PQ, Canada
[3] Univ Ulm, Dept Orthopaed Res & Biomech, D-89081 Ulm, Germany
关键词
computer-assisted surgery; cervical spine; posterior instrumentation; in vitro;
D O I
10.1007/PL00010024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Transarticular C1/2 screws are widely used in posterior cervical spine instrumentation. The use of pedicle screws in the cervical spine remains uncommon. Due to superior biomechanical stability compared to lateral mass screws, pedicle screws can be used, especially for patients with poor bone quality or defects in the anterior column. Nevertheless there are potential risks of iatrogenic damage to the spinal cord, nerve roots or the vertebral artery associated with both posterior cervical spine instrumentation techniques. Therefore, the aim of this study was to evaluate whether C1/2 transarticular screws as well as transpedicular screws in C3 and C4 can be applied safely and with high accuracy using a computer-assisted surgery (CAS) system. We used 13 human cadaver C0-C5 spine segments. We installed 1.4-mm Kirschner wires transarticular in C1/2, using a specially designed guide, and drilled 2.5-mm pedicle holes in C3 and C3 with the assistance of the CAS system. Hole positions were evaluated by palpation, CT and dissection. Forty-eight (92%) of the 52 drilled pedicles were correctly positioned after palpation, imaging and dissection. The vertebral artery was not injured in any specimen. All of the 26 C1/2 Kirschner wires were placed properly after imaging and dissection evaluations. No injury to vascular or bony structures was observed. C1/2 transarticular screws as well as transpedicular screws in the cervical spine can be applied safely and with high accuracy using a CAS system in vitro. Therefore, this technique may be used in a clinical setting, as it offers improved accuracy and reduced radiation dose for the patient and the medical staff. Nevertheless, users should take note of known sources of possible faults causing inaccuracies in order to prevent iatrogenic damage. Small pedicles, with a diameter of less than 4.0 mm, may not be suitable for pedicle screws.
引用
收藏
页码:S65 / S70
页数:6
相关论文
共 50 条
  • [1] Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study
    M. Richter
    L.-P. Amiot
    S. Neller
    P. Kluger
    W. Puhl
    European Spine Journal, 2000, 9 : S065 - S070
  • [2] Computer-assisted surgery in dorsal instrumentation of the cervical spine: an in vitro study
    Richter, M
    Amiot, LP
    Puhl, W
    ORTHOPADE, 2002, 31 (04): : 372 - 377
  • [3] Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
    Richter, M
    Mattes, T
    Cakir, B
    EUROPEAN SPINE JOURNAL, 2004, 13 (01) : 50 - 59
  • [4] Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
    Marcus Richter
    Thomas Mattes
    Balkan Cakir
    European Spine Journal, 2004, 13 : 50 - 59
  • [5] Computer-assisted spine surgery
    Schlenzka, D
    Laine, T
    Lund, T
    EUROPEAN SPINE JOURNAL, 2000, 9 (Suppl 1) : S57 - S64
  • [6] Computer-assisted spine surgery
    D. Schlenzka
    T. Laine
    T. Lund
    European Spine Journal, 2000, 9 : S057 - S064
  • [7] Feasibility study of a computer-assisted radioguided surgery system
    Massari, R.
    Trotta, C.
    Trinci, G.
    Sala, R.
    Basso, A.
    Zappa, E.
    Scopinaro, F.
    Soluri, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (2-3): : 360 - 365
  • [8] EFFECTS OF POSTERIOR INSTRUMENTATION ON AXIAL ROTATION OF THE LUMBAR SPINE - AN IN-VITRO BIOMECHANICAL STUDY
    GUNZBURG, R
    HUTTIN, WC
    JOURNAL OF SPINAL DISORDERS, 1995, 8 (02): : 103 - 110
  • [9] Clinical feasibility of the augmented reality computer-assisted spine surgery system for percutaneous vertebroplasty
    Ming-Hsien Hu
    Chiu-Ching Chiang
    Min-Liang Wang
    Nai-Yuan Wu
    Pei-Yuan Lee
    European Spine Journal, 2020, 29 : 1590 - 1596
  • [10] Clinical feasibility of the augmented reality computer-assisted spine surgery system for percutaneous vertebroplasty
    Hu, Ming-Hsien
    Chiang, Chiu-Ching
    Wang, Min-Liang
    Wu, Nai-Yuan
    Lee, Pei-Yuan
    EUROPEAN SPINE JOURNAL, 2020, 29 (07) : 1590 - 1596