Size and Shape of Bruch's Membrane Opening in Relationship to Axial Length, Gamma Zone, and Macular Bruch's Membrane Defects

被引:59
|
作者
Zhang, Qi [1 ]
Xu, Liang [1 ]
Wei, Wen Bin [2 ]
Wang, Ya Xing [1 ]
Jonas, Jost B. [1 ,3 ]
机构
[1] Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Inst Ophthalmol, Beijing Tongren Hosp, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Key Lab Intraocular Tumor Diag & Treatmen, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr,Beijing Tongren Hosp, Beijing, Peoples R China
[3] Ruprecht Karis Univ, Med Fac Mannheim, Dept Ophthalmol, Mannheim, Germany
基金
中国国家自然科学基金;
关键词
Bruch's membrane opening; axial length; myopia; parapapillary gamma zone; macular Bruch's membrane defects; optical coherence tomography; optic nerve head; Beijing Eye Study; OPTIC-NERVE HEAD; DISC MARGIN ANATOMY; HIGHLY MYOPIC EYES; COHERENCE TOMOGRAPHY; GLAUCOMA; PREVALENCE; TILT; ULTRASTRUCTURE; CLASSIFICATION; ASSOCIATION;
D O I
10.1167/iovs.19-27331
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess axial elongation-associated characteristics in Bruch's membrane opening (BMO) as the inner optic nerve head lamella. METHODS. Participants of the population-based Beijing Eye Study without glaucoma underwent optical coherence tomography for measurement of the BMO size and shape. RESULTS. The study included 365 individuals (mean age, 61.0 +/- 8.7 years; range, 50-88 years; axial length, 24.45 +/- 1.99 mm; range, 21.32-30.88 mm). Larger horizontal (mean: 1.62 +/- 0.28 mm) and vertical (mean: 1.74 +/- 0.27 mm) BMO diameters were linearly associated with longer axial length beyond an axial length of 26.0 mm (horizontal diameter: P < 0.001; standardized regression coefficient beta: 0.66; nonstandardized regression coefficient B: 0.22; 95% confidence interval (CI): 0.16, 0.27; vertical diameter: P < 0.001; beta: 40; B: 0.12; 95% CI: 0.06, 0.18). In multivariable analysis, wider largest gamma zone was associated with larger intrapapillary Bruch's membrane (BM) overhanging on the side opposite to the largest gamma zone (P = 0.006; beta: 0.14; B: 0.35; 95% CI: 0.10, 0.60) and with longer horizontal BMO diameter (P < 0.001; beta: 0.46; B: 0.59; 95% CI: 0.46, 0.73). The widest BM overhanging location (superior to nasal) was inversely correlated with the widest gamma zone location (inferior to temporal). Within the axial length group of >= 28.0 mm, eyes with macular BM defects had a less markedly increased BMO than those without macular BM defects (2.27 +/- 0.18 vs. 2.71 +/- 0.41 mm; P = 0.019). The difference between horizontal BMO diameter minus horizontal gamma zone width decreased (P < 0.001) with longer axial length. CONCLUSIONS. Beyond 26.0 mm of axial length, horizontal and vertical BMO diameter increased by 0.21 mm (95% CI: 0.16, 0.27) and 0.12 mm (95% CI: 0.06, 0.18), respectively, for each millimeter of axial elongation. Gamma zone may develop due to an axial elongation-associated BMO enlargement (beta: 0.46) and, to a minor degree, a BMO shift in direction to the macula (b: 0.14). A large gamma zone may be protective against myopic macular BM defects.
引用
收藏
页码:2591 / 2598
页数:8
相关论文
共 50 条
  • [1] Macular Bruch's Membrane Defects and Axial Length: Association with Gamma Zone and Delta Zone in Peripapillary Region
    Jonas, Jost B.
    Ohno-Matsui, Kyoko
    Spaide, Richard F.
    Holbach, Leonard
    Panda-Jonas, Songhomitra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (02) : 1295 - 1302
  • [2] Bruch' s membrane thickness in relationship to axial length
    Bai, Hai Xia
    Mao, Ying
    Shen, Ling
    Xu, Xiao Lin
    Gao, Fei
    Zhang, Zhi Bao
    Li, Bin
    Jonas, Jost B.
    PLOS ONE, 2017, 12 (08):
  • [3] Myopic macular Bruch's membrane defects
    Panda-Jonas, Songhomitra
    Auffarth, Gerd U.
    Jonas, Jost B.
    Jonas, Rahul A.
    HELIYON, 2023, 9 (02)
  • [4] Macular Bruch's membrane defects in Hi
    Jonas, J.
    You, Q.
    Peng, X. Y.
    Xu, L.
    Wei, W. B.
    Wang, Y.
    Chen, C. X.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [5] Myopic macular Bruch's membrane defects
    Jonas, Jost
    Panda-Jonas, Songhomitra
    Jonas, Rahul
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [6] Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study
    Jonas, Jost B.
    Wang, Ya Xing
    Zhang, Qi
    Liu, Yi
    Xu, Liang
    Wei, Wen Bin
    PLOS ONE, 2015, 10 (08):
  • [7] Bruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane
    Kromer, Robert
    Spitzer, Martin Stephan
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [8] Photomelded Bruch's membrane patch grafts: A novel concept to treat Bruch's membrane defects in age-related macular degeneration
    Tezel, TH
    Del Priore, LV
    Kaplan, HJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U202 - U202
  • [9] Determinants and Characteristics of Bruch's Membrane Opening and Bruch's Membrane Opening-Minimum Rim Width in a Normal Japanese Population
    Araie, Makoto
    Iwase, Aiko
    Sugiyama, Kazuhisa
    Nakazawa, Toru
    Tomita, Goji
    Hangai, Masanori
    Yanagi, Yasuo
    Murata, Hiroshi
    Tanihara, Hidenobu
    Burgoyne, Claude F.
    Chauhan, Balwantray C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (10) : 4106 - 4113
  • [10] Macular Bruch's membrane defects and other myopic lesions in high myopia
    Li-Hui Meng
    Ming-Zhen Yuan
    Xin-Yu Zhao
    You-Xin Chen
    International Journal of Ophthalmology, 2022, 15 (03) : 466 - 473