Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery

被引:5
|
作者
Zhang, Jing [1 ]
He, Fanglin [1 ]
Liu, Yan [1 ]
Fan, Xianqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Key Lab Orbital Dis & Ocular Oncol, Shanghai Peoples Hosp 9, Dept Ophthalmol,Sch Med, 639 Zhi Zao Ju Rd, Shanghai 200011, Peoples R China
关键词
implantable collamer lens with a central hole; visual quality; residual refractive error; PHAKIC INTRAOCULAR-LENS; IN-SITU KERATOMILEUSIS; LOW-TO-MODERATE; OPTICAL-QUALITY; OCULAR ABERRATIONS; MYOPIA; LASIK; VISION; ENHANCEMENT; HYPEROPIA;
D O I
10.3892/etm.2020.9289
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The present study aimed to assess the visual and refractive outcomes of an implantable collamer lens with a central hole (ICL V4c) for residual refractive error correction after corneal refractive surgery in individuals with myopia. A total of 16 eyes of eight consecutive patients with myopia undergoing ICL V4c implantation after corneal refractive surgery were investigated. The uncorrected visual acuity (VA) and best-corrected VA were examined prior to surgery and at 1, 3 and 6 months after surgery. The post-operative values of the modulation transfer function (MTF) cutoff frequency, Strehl ratio (SR), objective scattering index (OSI) and Optical Quality Analysis System (OQAS) values (OVs) were quantitatively assessed using an OQAS. At 6 months after surgery, the mean uncorrected LogMAR VA was 0.06 +/- 0.10 and the values had improved in 100% of the eyes. The mean MTF cutoff frequency, SR, OSI, OV 100%, OV 20% and OV 9%, were 31.294 +/- 4.321 cycles/degree, 0.187 +/- 0.039, 1.399 +/- 0.274, 1.066 +/- 0.261, 0.748 +/- 0.287 and 0.509 +/- 0.229, respectively. In conclusion, ICL V4c implantation for the correction of residual refractive error after corneal refractive surgery appeared feasible and safe and also had an excellent optical performance. However, long-term changes in visual quality require further investigation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Implantable collamer lens for residual refractive error after corneal refractive surgery
    Chen, Xun
    Wang, Xiao-Ying
    Zhang, Xi
    Chen, Zhi
    Zhou, Xing-Tao
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (10) : 1421 - 1426
  • [2] Implantable collamer lens for residual refractive error after corneal refractive surgery
    Xun Chen
    Xiao-Ying Wang
    Xi Zhang
    Zhi Chen
    Xing-Tao Zhou
    International Journal of Ophthalmology, 2016, (10) : 1421 - 1426
  • [3] Piggyback implantable collamer lens implantation for the correction of residual refractive errors after cataract surgery: a multicenter study
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kitazawa, Yoshihiro
    Kojima, Takashi
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    ACTA OPHTHALMOLOGICA, 2019, 97 (06) : E946 - E947
  • [4] Correction of Residual Refractive Error in Pseudophakic Eyes With the Use of a Secondary Piggyback Toric Implantable Collamer Lens
    Kojima, Takashi
    Horai, Rie
    Hara, Shuya
    Nakamura, Hideki
    Nakamura, Tomoaki
    Satoh, Yuya
    Ichikawa, Kazuo
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (10) : 766 - 769
  • [5] Surgical Correction of Presbyopic Ametropia With Non-refractive Transparent Corneal Inlay and an Implantable Collamer Lens
    Gutierrez Amoros, Carlos
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (12) : 852 - 854
  • [6] Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Montes-Mico, Robert
    Valcarcel, Beatriz
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (02) : 244 - 250
  • [7] Add-on Implantable Collamer Lens in complex eyes with refractive surprise after cataract surgery
    van der Vossen, M. J. B.
    van der Meulen, I. J. E.
    Lapid-Gortzak, R.
    ACTA OPHTHALMOLOGICA, 2023, 101 : 7 - 7
  • [8] Refractive enhancements for residual refractive error after cataract surgery
    Moshirfar, Majid
    Thomson, Andrew C.
    Thomson, Robert J.
    Martheswaran, Tanisha
    McCabe, Shannon E.
    CURRENT OPINION IN OPHTHALMOLOGY, 2021, 32 (01) : 54 - 61
  • [9] REFRACTIVE CORNEAL SURGERY - THE USE OF IMPLANTABLE ALLOPLASTIC LENS MATERIAL
    WERBLIN, TP
    BLAYDES, JE
    FRYCZKOWSKI, A
    PEIFFER, R
    AUSTRALIAN JOURNAL OF OPHTHALMOLOGY, 1983, 11 (04): : 325 - 331
  • [10] Corneal or lens refractive surgery?
    Neuhann, T