Simplified methods of design, implementation, and characterization of a spectrometer-based FD-OCT

被引:2
|
作者
Meemon, Panomsak [1 ]
Palawong, Kunakorn [1 ]
Pongchalee, Pornthep [1 ]
机构
[1] Suranaree Univ Technol, Inst Sci, Sch Laser Technol & Photon, Nakhon Ratchasima 30000, Thailand
关键词
optical coherence tomography; spectrometer design; characterization; MTF measurement; calibration; OPTICAL COHERENCE TOMOGRAPHY;
D O I
10.1117/12.2036517
中图分类号
TH742 [显微镜];
学科分类号
摘要
In this work, we report simple optical design of a high speed and high spectral resolution spectrometer based on the first order calculation. The spectrometer was design and optimized for high speed detection of spectral interference signal to be used as a detection unit of our developed Frequency Domain Optical Coherence Tomography (FD-OCT). We then detailed the hardware implementation of both the spectrometer and the FD-OCT system in our laboratory at Suranaree University of Technology, Thailand, by utilizing only off-the-shelf optical components. The spectrometer is capable of capturing of the spectral interference fringes at up to the camera limit of 130,000 spectra per second, enabling crosssectional microscopic imaging of biological sample of more than 100 frames per second (for a 1000 depth scans per frame). In addition, we reported several simple yet robust techniques for characterization of the system performance in the context of FD-OCT 3D imaging, such as an effective lateral resolution, depth scale calibration, and depth penetration limit. The development of this high speed and high resolution spectrometer is part of our ultimate goal to develop a prototype of a research-grade FD-OCT system that provides better imaging speed and resolution in comparing to available commercial OCT systems at relatively lower cost. The design of low-cost, high performance FD-OCT system would make the technology widely accessible to other researchers in the field of biomedical research and related areas in Thailand in the next few years.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Optimum design of spectrometer in FD-OCT
    Hu, Zhilin
    Rollins, Andrew M.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [2] Design, Implementation, and Characterization of Spectrometer-Based Spectral Domain Optical Coherence Tomography
    Palawong, Kunakorn
    Pongchalee, Pornthep
    Chuamchaitrakool, Porntip
    Tachatraiphop, Sukanya
    Widjaja, Joewono
    Meemon, Panomsak
    INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS 2013 AND TWELFTH ASIAN CONFERENCE ON EXPERIMENTAL MECHANICS, 2014, 9234
  • [3] Numerical calibration method for a multiple spectrometer-based OCT system
    Miao, Yusi
    Song, Jun
    Hsu, Destiny
    Ng, Ringo
    Jian, Yifan
    Sarunic, Marinko, V
    Ju, Myeong Jin
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (03) : 1685 - 1701
  • [4] Single-Shot Full Complex Spectrum Spectrometer-Based OCT
    Gelikonov, Grigory V.
    Gelikonov, Valentin M.
    Shilyagin, Pavel A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [5] Image-based cross-calibration method for multiple spectrometer-based OCT
    Miao, Yusi
    Song, Jun
    Ju, Myeong Jin
    OPTICS LETTERS, 2022, 47 (19) : 5096 - 5100
  • [6] A new diagnostic model of primary open angle glaucoma based on FD-OCT parameters
    Zheng, Ya-Jie
    Pan, Ying-Zi
    Li, Xue-Ying
    Fang, Yuan
    Li, Mei
    Qiao, Rong-Hua
    Cai, Yu
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (06) : 951 - 957
  • [7] A new diagnostic model of primary open angle glaucoma based on FD-OCT parameters
    Ya-Jie Zheng
    Ying-Zi Pan
    Xue-Ying Li
    Yuan Fang
    Mei Li
    Rong-Hua Qiao
    Yu Cai
    International Journal of Ophthalmology, 2018, (06) : 951 - 957
  • [8] Experimental Investigation into High Speed FD-OCT Imaging based on Orthogonally Polarized Light
    Cheng, Hsu-Chih
    Shiu, Ming-Shiuan
    MECHATRONIC SYSTEMS AND AUTOMATION SYSTEMS, 2011, 65 : 315 - +
  • [9] Multimode Memory-Based FFT Processor for Wireless Display FD-OCT Medical Systems
    Tang, Song-Nien
    Jan, Fu-Chiang
    Cheng, Hui-Wen
    Lin, Ching-Kai
    Wu, Guo-Zua
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2014, 61 (12) : 3394 - 3406
  • [10] Comparison of uniform resampling and nonuniform sampling direct-reconstruction methods in k-space for FD-OCT
    Yang, Yanrong
    Dai, Yun
    Zhou, Yuehua
    Yang, Yaliang
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2023, 16 (05)