Flow cytometric aberrancies in plasma cell myeloma and MGUS - correlation with laboratory parameters

被引:7
|
作者
Gupta, Sarika [1 ]
Karandikar, Nitin J. [1 ]
Ginader, Timothy [2 ]
Bellizzi, Andrew M. [1 ]
Holman, Carol J. [1 ]
机构
[1] Univ Iowa, Dept Pathol, Iowa City, IA 52242 USA
[2] Univ Iowa, Holden Comprehens Canc Ctr, Iowa City, IA 52242 USA
关键词
plasma cell myeloma; monoclonal gammopathy; immunophenotyping; flow cytometry; MINIMAL RESIDUAL DISEASE; MONOCLONAL GAMMOPATHY; MULTIPLE-MYELOMA; BONE-MARROW; UNDETERMINED SIGNIFICANCE; RISK-FACTOR; PROGRESSION; EXPRESSION; CRITERIA; DIAGNOSIS;
D O I
10.1002/cyto.b.21624
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BackgroundMultiparametric flow cytometry is a useful tool for diagnosis of plasma cell (PC) dyscrasias and assessment of minimal residual disease in plasma cell myeloma (PCM). However, the immunophenotypic differences between the clonal PCs of PCM and those of monoclonal gammopathy of undetermined significance (MGUS) as well as the correlation of these flow cytometric markers with pertinent laboratory parameters have not been evaluated. MethodsWe retrospectively identified all newly diagnosed treatment-naive PCM and MGUS patients between 09/2014 and 06/2015 who underwent 10-color flow-cytometric evaluation: CD45, CD38, CD138, cKappa, cLambda, CD19, CD27, CD28, CD56, CD117. FACSDiva analysis was used to identify antigenic aberrancies and associations with pertinent laboratory parameters were evaluated. ResultsAll cases demonstrated at least two aberrancies. There was a trend toward a greater number of aberrancies in PCM, with 68% showing >/= 4 aberrancies compared with 44% in MGUS (P=0.11). The only marker more frequently aberrant in one disease class was CD19, aberrant in 68% of PCM and 25% of MGUS (P<0.01). In PCM, significant associations were found for CD56 non-aberrancy (P=0.05) and the presence of amyloid and CD27 aberrancy and normal serum albumin (P=0.05). In MGUS, CD117 expression was associated with normal hemoglobin (P=0.03). ConclusionsThe PCs of PCM show a trend toward more antigenic aberrancy than those of MGUS. There is significant association between the antigenic profiles of PCM/MGUS and clinical parameters including amyloidosis, albumin level, and hemoglobin. (c) 2018 International Clinical Cytometry Society
引用
收藏
页码:500 / 508
页数:9
相关论文
共 50 条
  • [1] Cytologic and flow cytometric evaluation of bone lesions in plasma cell myeloma
    Momtahen, S
    Yared, M
    Glenn, R
    Gokden, M
    LABORATORY INVESTIGATION, 2006, 86 : 67A - 67A
  • [2] Cytologic and flow cytometric evaluation of bone lesions in plasma cell myeloma
    Momtahen, S
    Yared, M
    Glenn, R
    Gokden, M
    MODERN PATHOLOGY, 2006, 19 : 67A - 67A
  • [3] Plasma Cell Myeloma Evaluation by Flow Cytometric lmmunophenotyping: Aberrant Antigen Expression and Correlation with Cytogenetic/FISH Abnormalities
    Husman, A. L.
    Toscano, M.
    Chandler, K. L.
    Lonial, S.
    Kaufman, J. L.
    Mann, K. P.
    LABORATORY INVESTIGATION, 2012, 92 : 342A - 342A
  • [4] Plasma Cell Myeloma Evaluation by Flow Cytometric Immunophenotyping: Aberrant Antigen Expression and Correlation with Cytogenetic/FISH Abnormalities
    Husman, A. L.
    Toscano, M.
    Chandler, K. L.
    Lonial, S.
    Kaufman, J. L.
    Mann, K. P.
    MODERN PATHOLOGY, 2012, 25 : 342A - 342A
  • [5] Flow-cytometric detection of phenotypic aberrancies in canine small clear cell lymphoma
    Martini, V.
    Poggi, A.
    Riondato, F.
    Gelain, M. E.
    Aresu, L.
    Comazzi, S.
    VETERINARY AND COMPARATIVE ONCOLOGY, 2015, 13 (03) : 281 - 287
  • [6] Flow Cytometric Ploidy Analysis in Acute Lymphoblastic Leukemia and Plasma Cell Myeloma
    Bommannan, Karthik
    INDIAN JOURNAL OF MEDICAL AND PAEDIATRIC ONCOLOGY, 2023, 44 (05) : 525 - 533
  • [7] Review of phenotypic markers used in flow cytometric analysis of MGUS and MM, and applicability of flow cytometry in other plasma cell disorders
    Raja, Karthick R. M.
    Kovarova, Lucie
    Hajek, Roman
    BRITISH JOURNAL OF HAEMATOLOGY, 2010, 149 (03) : 334 - 351
  • [8] Flow cytometric (FC) evaluation of the bone marrow plasma cell (BMPC) clones in patients with multiple myeloma (MM), monoclonal gammopathy of uncertain significance (MGUS) and normal plasmacytosis (polyPC)
    Mazzone, C.
    Vigna, E.
    Gentile, M.
    Lucia, E.
    Caruso, N.
    Greco, R.
    Dodaro, G.
    Cavallaro, E.
    Morelli, R.
    Iorio, C.
    Qualtieri, G.
    Naccarato, M.
    Bisconte, M. G.
    Gentile, C.
    Cavalcanti, S.
    Morabito, F.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 : 140 - 141
  • [9] Flow Cytometric Determination of Circulating Plasma Cells in Newly Diagnosed Myeloma
    Mohapatra, P. N.
    Iqbal, S.
    Kumar, R.
    Sharma, A.
    Raina, V.
    CLINICAL LYMPHOMA & MYELOMA, 2009, 9 : S88 - S88
  • [10] Four-color flow cytometric analysis of myeloma plasma cells
    Kobayashi, Shoichi
    Hyo, Rie
    Amitani, Yukiko
    Tanaka, Masatsugu
    Hashimoto, Chizuko
    Sakai, Rika
    Tamura, Takeshi
    Motomura, Shigeki
    Maruta, Atsuo
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 126 (06) : 908 - 915