Case Studies of Sizing Pressure Relief Valves for Two-Phase Flow

被引:12
|
作者
Schmidt, Juergen [1 ]
Egan, Simon [2 ]
机构
[1] BASF SE, Safety & Fluid Flow Technol, D-67056 Ludwigshafen, Germany
[2] Rhodia Serv CRTL, St Fons, France
关键词
Modeling; Safety techniques; Two-phase flow; Valves; SAFETY VALVES; THROTTLING DEVICE; ORIFICES; NOZZLES;
D O I
10.1002/ceat.200800572
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The most widely accepted methods of sizing safety valves for two-phase-flow, namely the homogeneous equilibrium model of Leung, the HNE-DS model proposed in ISO 4126-10, and the latest version of the API 520 two-point omega-model were compared to each other. The thermodynamic and mechanical nonequilibrium effect included in the ISO (HNE-DS) model dominates the more rigorous property data calculation (API) at low and moderate reduced pressures, whereas the critical flow rates become closer when approaching the thermodynamic critical point. In addition, the predictive accuracy of the ISO (HNE-DS) model was analyzed by means of roughly 3000 experimental data points from the literature. This data includes flashing steam/water, non-flashing air/water, and initially sub-cooled water flowing through safety valves from several manufacturers. The calculated flow rates are in good agreement with the measurements.
引用
收藏
页码:263 / 272
页数:10
相关论文
共 50 条
  • [1] Perspectives on relief valve sizing for two-phase flow
    Darby, R
    INTERNATIONAL SYMPOSIUM ON RUNAWAY REACTIONS, PRESSURE RELIEF DESIGN, AND EFFLUENT HANDLING, 1998, : 365 - 397
  • [2] Geometry influence on safety valves sizing in two-phase flow
    Boccardi, Gino
    Bubbico, Roberto
    Celata, Gian Piero
    Di Tosto, Fausto
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2008, 21 (01) : 66 - 73
  • [3] Benchmarking of two-phase flow through safety relief valves and pipes
    Adair, SP
    Fisher, HG
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 1999, 12 (04) : 269 - 297
  • [4] Pressure relief system design for vapour or two-phase flow?
    Wehmeier, G.
    Westphal, F.
    Friedel, L.
    Process Safety and Environmental Protection: Transactions of the Institution of Chemical Engineers, Part B, 1994, 72 (03): : 142 - 148
  • [5] Select the best model for two-phase relief sizing
    Darby, R
    Meiller, PR
    Stockton, JR
    CHEMICAL ENGINEERING PROGRESS, 2001, 97 (05) : 56 - 64
  • [6] PRESSURE DROP IN BENDS AND VALVES IN TWO-PHASE REFRIGERANT FLOW.
    Norstebo, A.
    Chemical Engineering World, 1986, 21 (06): : 55 - 60
  • [7] Sizing Calculations for Pressure-Relief Valves
    Kim, Jung Seob
    Dunsheath, Heather Jean
    Singh, Navneet Radheshyam
    CHEMICAL ENGINEERING, 2013, 120 (02) : 35 - 39
  • [8] Properly size pressure-relief values for two-phase flow
    Darby, R
    Self, FE
    Edwards, VH
    CHEMICAL ENGINEERING, 2002, 109 (06) : 68 - 74
  • [9] Sizing calculations for pressure-relief valves
    Kim, J.S. (jkim3@sk.com), 1600, Access Intelligence (120):
  • [10] Sizing of throttling device for gas/liquid two-phase flow - Part 1: Safety valves
    Diener, R
    Schmidt, A
    PROCESS SAFETY PROGRESS, 2004, 23 (04) : 335 - 344