Optical coherence tomography analysis of filtering blebs after long-term, functioning trabeculectomy and XEN® stent implant

被引:29
|
作者
Teus, Miguel A. [1 ,2 ]
Paz Moreno-Arrones, Javier [1 ]
Castano, Beatriz [1 ]
Castejon, Miguel A. [1 ]
Bolivar, Gema [1 ]
机构
[1] Hosp Univ Principe Asturias, Dept Ophthalmol, Carretera Alcala Meco S-N, Madrid 28805, Spain
[2] Univ Alcala, Sch Med, Madrid, Spain
关键词
Bleb characteristics; XEN implant; Trabeculectomy; Anterior segment OCT; Intraocular pressure; GLAUCOMA; SURGERY;
D O I
10.1007/s00417-019-04272-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The purpose of this study was to use Triton (R) SweptSource OCT to evaluate the morphology of blebs formed when eyes are treated with XEN (R) implants and to compare these with the blebs in successfully functioning eyes after trabeculectomy (TB) and with eyes of healthy controls. Methods A cross-sectional, observational study. We analyzed 25 eyes, 15 after TB and 10 with XEN (R) implants, comparing them with 23 healthy eyes (controls). We evaluated the conjunctival morphology of the eyes using AS-OCT. The main parameters evaluated were bleb height, sub-epithelial fibrosis, epithelial thickness, and changes in intraocular pressure (IOP). Results We found that the filtering blebs formed in eyes in which a XEN (R) stent was implanted were significantly flatter (bleb height 417 +/- 183 mu m) than the blebs formed in TB eyes (bleb height 618 +/- 256 mu m, p < 0.05). Moreover, sub-epithelial fibrosis did not develop in any of the blebs produced by the XEN stent, whereas some fibrosis was evident in 40% of the blebs that formed after TB (p < 0.05). The epithelium was thicker when the XEN implant was used (65 +/- 18.5 mu m) than when eyes underwent TB (60 +/- 17.7 mu m), and it was thicker than in control eyes (51 +/- 9.7 mu m, p < 0.05). Moreover, the decrease in the IOP induced by the XEN (R) stent (-8.5 +/- 5.3 mmHg) was similar to that produced by TB (-8.8 +/- 5.2 mmHg, p > 0.05). Conclusions Filtering blebs obtained after the introduction of a XEN (R) stent were morphologically distinct to those produced by TB, and they are more similar to the healthy conjunctiva.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [1] Optical coherence tomography analysis of filtering blebs after long-term, functioning trabeculectomy and XEN® stent implant
    Miguel A. Teus
    Javier Paz Moreno-Arrones
    Beatriz Castaño
    Miguel A. Castejon
    Gema Bolivar
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 1005 - 1011
  • [2] Three-dimensional anterior segment optical coherence tomography of filtering blebs after trabeculectomy
    Miura, Masahiro
    Kawana, Keisuke
    Iwasaki, Takuya
    Kiuchi, Takahiro
    Oshika, Tetsuro
    Mori, Hideki
    Yamanari, Masahiro
    Makita, Shuichi
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    JOURNAL OF GLAUCOMA, 2008, 17 (03) : 193 - 196
  • [3] Structural imaging of conjunctival filtering blebs in XEN gel implantation and trabeculectomy: a confocal and anterior segment optical coherence tomography study
    Matteo Sacchi
    Luca Agnifili
    Lorenza Brescia
    Francesco Oddone
    Edoardo Villani
    Paolo Nucci
    Leonardo Mastropasqua
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1763 - 1770
  • [4] Morphology of functioning trabeculectomy blebs using anterior segment optical coherence tomography
    Khamar, Mayuri B.
    Soni, Shruti R.
    Mehta, Siddharth V.
    Srivastava, Samaresh
    Vasavada, Viraj A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (06) : 711 - 714
  • [5] Structural imaging of conjunctival filtering blebs in XEN gel implantation and trabeculectomy: a confocal and anterior segment optical coherence tomography study
    Sacchi, Matteo
    Agnifili, Luca
    Brescia, Lorenza
    Oddone, Francesco
    Villani, Edoardo
    Nucci, Paolo
    Mastropasqua, Leonardo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (08) : 1763 - 1770
  • [6] Quantitative analysis of filtering blebs using optical coherence tomography following trabeculectomy with mitomycin C
    Mori, K
    Kawashima, A
    Kobayashi, L
    Kinoshita, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S5 - S5
  • [7] Evaluation of Successful and Failed Filtering Blebs after Trabeculectomy Using Anterior Segment Optical Coherence Tomography
    Tekin, Serek
    Seven, Erbil
    Batur, Muhammed
    Ozer, Muhammet Derda
    Yasar, Tekin
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (01): : 1 - 5
  • [8] Morphological analysis of functional filtering blebs with anterior segment optical coherence tomography: A short-term prediction for success of trabeculectomy
    Raj, Anuradha
    Bahadur, Harsh
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) : 1978 - 1985
  • [9] Qualitative and quantitative analysis of filtering blebs with optical coherence tomography
    Napoli, Pietro Emanuele
    Zucca, Ignazio
    Fossarello, Maurizio
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2014, 49 (02): : 210 - 216
  • [10] Macroscopic analysis of filtering bleb functionality after XEN Gel Stent implantation with Anterior Segment Optical Coherence Tomography
    Costa, L.
    Cardigos, J.
    Crisostomo, S.
    Anjos, R.
    Cardoso, M. Sa
    Gomes, T.
    ACTA OPHTHALMOLOGICA, 2016, 94