The effect of amniotomy on urine protein creatinine ratio test accuracy

被引:1
|
作者
Gonzalez, Aaron Herrera [1 ]
Quinn, Sara [1 ]
Lennon, Jessica [1 ]
Zabo, Jordan [1 ]
Dierking, Elizabeth [1 ]
Anasti, James [1 ]
机构
[1] St Lukes Univ Hlth Network, Dept Obstet & Gynecol, 801 Ostrum St, Bethlehem, PA 18015 USA
来源
关键词
amniotic fluid; protein creatinine ratio; preeclampsia; urine protein; pregnancy; gestational hypertension; PREECLAMPSIA; QUANTITATION; PREVENTION; PREGNANCY;
D O I
10.2147/IJWH.S201210
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction: While the gold standard for evaluation of maternal urinary protein is a 24-hr urine collection, spot urine protein/creatinine ratio has been instituted as an alternative for quantification proteinuria. Though it seems intuitive to obtain a catheterized urine sample on patients with ruptured amniotic membranes, it is a common practice to forgo this step under the argument that there is no data to show its necessity. Data on the effect of amniotomy, spontaneous or artificial, on the accuracy of the protein/creatinine ratio are scant. The present study was designed to address this issue and objectively compare protein/creatinine ratio values on samples obtained from the same patient before and after amniotomy. Methods: We conducted a prospective non-interventional study. Women presenting in active labor or for labor induction with intact amnion were enrolled. Separate random catch urines for the protein/creatinine ratio were obtained prior to and immediately after spontaneous or assisted amniotomy. The urine samples were analyzed in the hospital chemistry department, and the results were compared. Results: Of the 137 patients consented, 63 had pre- and post-amniotomy protein/creatinine ratios collected. The mean age was 28.5 +/- 5.6 y, Gravidity 2.7 +/- 1.6, Gestational age 39.2 +/- 1.8 wks, and BMI 31.6 +/- 6.4 kg/m(2). Comorbidities included gestational diabetes (5/63, 7.9%), chronic hypertension (3/63, 4.7%), and pre-eclampsia (5/63, 7.9%). Post-amniotomy protein/ creatinine ratio was significantly higher than pre-amniotomy ratio (1.3 +/- 2.5 vs 0.34 +/- 0.83, p<0.001). In addition, the number of patients with protein/creatinine ratio greater than 0.3 was higher post-amniotomy than pre-amniotomy (41/63 vs 14/63, p<0.001). Conclusion: Amniotomy results in a false elevation of the protein/creatinine ratio in term patients. Urine samples should be obtained by catheterization in the setting of ruptured membranes to reduce falsely elevated results. Although the same can be assumed for other gestational ages, further studies including this population need to be conducted.
引用
收藏
页码:371 / 375
页数:5
相关论文
共 50 条
  • [1] Amniotomy Affects the Urine Protein Creatinine Ratio Accuracy in the Diagnosis of Preeclampsia
    Quinn, Sara
    Lennon, Jessica
    Gonzalez, Aaron Herrera
    Dierking, Elizabeth
    Anasti, James
    [J]. OBSTETRICS AND GYNECOLOGY, 2017, 129 : 32S - 32S
  • [2] Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration
    Yang, Chih-Yu
    Chen, Fu-An
    Chen, Chun-Fan
    Liu, Wen-Sheng
    Shih, Chia-Jen
    Ou, Shuo-Ming
    Yang, Wu-Chang
    Lin, Chih-Ching
    Yang, An-Hang
    [J]. PLOS ONE, 2015, 10 (09):
  • [3] Contemporary Test Performance of the Random Urine Protein-to-creatinine Ratio
    Champion, Macie L.
    Becker, David A.
    McIlwraith, Claire
    Blanchard, Christina T.
    Szychowski, Jeff M.
    Kim, Dhong-Jin
    Jauk, Victoria C.
    Harper, Lorie M.
    Casey, Brian M.
    Tita, Alan T.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 (08) : 1055 - 1061
  • [4] Spot urine protein to creatinine ratio
    Guido Filler
    Shih-Han Susan Huang
    [J]. Pediatric Nephrology, 2017, 32 : 917 - 919
  • [5] Spot urine protein to creatinine ratio
    Filler, Guido
    Huang, Shih-Han Susan
    [J]. PEDIATRIC NEPHROLOGY, 2017, 32 (06) : 917 - 919
  • [6] Effect of storage time on the urine protein: creatinine ratio in alkaline ovine urine
    Athanasiou, Labrini V.
    Katsoulos, Panagiotis D.
    Spanou, Victoria M.
    Pazarakioti, Aikaterini T.
    Katsogiannou, Eleni G.
    Iliadi, Ioanna
    Baka, Rania
    Polizopoulou, Zoe S.
    [J]. JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2021, 33 (06) : 1176 - 1179
  • [7] SINGLE VOIDED URINE PROTEIN CREATININE RATIO
    PERAZELLA, MA
    [J]. MAYO CLINIC PROCEEDINGS, 1995, 70 (03) : 308 - 309
  • [8] Urine protein: Urine creatinine ratio correlation with diabetic retinopathy
    Mujeeb, Samya
    Rodrigues, Gladys R.
    Nayak, Rajesh R.
    Kamath, Ajay R.
    Kamath, Sumana J.
    Kamath, Gurudutt
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (11) : 3359 - 3363
  • [9] SPOT URINE ALBUMIN-TO-CREATININE RATIO EQUIVALENT TO PROTEIN-TO-CREATININE RATIO
    Moon, Kyoung Hyoub
    Yang, Soohyun
    Lee, Dong-Young
    Kim, HyeWon
    Kim, Beom
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 373 - 374
  • [10] The diagnostic accuracy of a point of care urine albumin to creatinine ratio test, and urine dipstick analysis in a resource limited setting
    Currin, S.
    Fabian, J.
    George, J.
    [J]. CLINICA CHIMICA ACTA, 2022, 530 : S226 - S226