Enhanced shear punching capacity by the use of post installed concrete screws

被引:24
|
作者
Woerle, Patrick [1 ]
机构
[1] Univ Innsbruck, Fak Tech Wissenschaften, Inst Konstrukt & Mat Wissensch, A-6020 Innsbruck, Austria
关键词
Shear; Punching; Concrete screws; Post-installed; Anchor; Reinforcement; PLASTIC-DAMAGE MODEL; FLAT-SLABS; REINFORCEMENT;
D O I
10.1016/j.engstruct.2013.12.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the field of reinforced concrete structures, there is a growing need for structural engineers to develop methods that raise the shear punching capacity of existing flat slabs. Unfortunately, current structural solutions that aim to enhance the shear punching capacity suffer from many technical and economic problems. The aim of this paper is to develop a new and more efficient method for raising the shear punching capacity of existing concrete structures. The main idea behind this new strengthening method is to use post installed concrete screws as a punching reinforcement. This new strengthening method was analysed within an experimental framework performing shear punching tests on samples containing post-installed concrete screws. In addition to experimental tests, numerical simulations, based on the finite element method, were executed to derive a simplified model to calculate the shear punching capacity of strengthened slabs. In comparison to currently available structural methods, this new method, based on the use of post installed concrete screws, satisfies much of the criteria required for effective structural reinforcement. Along with robustness and economic efficiency, this new strengthening method leads to a significant increase in shear punching capacity. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:41 / 51
页数:11
相关论文
共 50 条
  • [1] Concrete screws as a post-installed punching shear reinforcement
    Walkner, Rupert
    Spiegl, Matthias
    Feix, Juergen
    [J]. STRUCTURAL CONCRETE, 2021, 22 (02) : 709 - 725
  • [2] Concrete screws as a post-installed punching reinforcement
    Spiegl, Matthias
    Walkner, Rupert
    Feix, Juergen
    [J]. STRUCTURAL CONCRETE, 2021, 22 (04) : 2289 - 2308
  • [3] Improving the punching shear and shear capacity of reinforced concrete elements with a new post-installed retrofitting system
    Buhler, Jochen
    Vilotijevic, Danijel
    [J]. GRADEVNSKI MATERIJIALI I KONSTRUKCIJE-BUILDING MATERIALS AND STRUCTURES, 2022, 65 (01): : 37 - 45
  • [4] Enhanced safety with post-installed punching shear reinforcement
    Kunz, J.
    Ruiz, M. Fernandez
    Muttoni, A.
    [J]. TAILOR MADE CONCRETE STRUCTURES: NEW SOLUTIONS FOR OUR SOCIETY, 2008, : 152 - 152
  • [5] Use of post-installed screws in the compressive strength assessment of in-situ concrete
    Sourav, M. S. N. A.
    Al-Sabah, C.
    McNally, C.
    [J]. LIFE-CYCLE ANALYSIS AND ASSESSMENT IN CIVIL ENGINEERING: TOWARDS AN INTEGRATED VISION, 2019, : 1923 - 1930
  • [6] Concrete screws as punching shear strengthening for static and cyclic loaded plates
    Spiegl, M.
    Walkner, R.
    Axmann, H.
    Pilch, E.
    Schoen, A.
    Feix, J.
    [J]. BAUINGENIEUR, 2018, 93 : 274 - 285
  • [7] Evaluation of design concepts for post-installed punching shear retrofitting
    Olalusi, Oladimeji B.
    Spyridis, Panagiotis
    Strauss, Alfred
    [J]. STRUCTURES, 2020, 27 : 1710 - 1721
  • [8] Recycled aggregate concrete slab punching shear capacity
    Sahoo, Saumyaranjan
    Singh, Bhupinder
    [J]. STRUCTURES, 2020, 24 : 426 - 443
  • [9] Punching Shear Capacity of Recycled Aggregate Concrete Slabs
    Leelatanon, Satjapan
    Imjai, Thanongsak
    Setkit, Monthian
    Garcia, Reyes
    Kim, Boksun
    [J]. BUILDINGS, 2022, 12 (10)
  • [10] Tensile and shear capacity of post-installed chemical adhesive anchors in lightweight concrete
    Du, Hongkai
    Wang, Haimeng
    Wang, Jinyu
    Wang, Yuandong
    Yang, Fuxiong
    [J]. STRUCTURES, 2024, 61